Diagnostic accuracy of intraoral film and direct digital images for detection of simulated recurrent decay

被引:0
|
作者
Nair, MK
Ludlow, JB
May, KN
Nair, UP
Johnson, MP
Close, JM
机构
[1] Univ Pittsburgh, Sch Dent Med, Pittsburgh, PA 15261 USA
[2] Univ N Carolina, Sch Dent, Chapel Hill, NC USA
关键词
D O I
暂无
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
This study compared the diagnostic accuracy of bitewing images for detection of simulated recurrent caries using the following imaging modalities: Ektaspeed Plus film and different digital imaging system technologies comprised of a charge-coupled device (CCD) based digital imaging unit, a photo-stimulable phosphor (PSP) based unit and contrast-and brightness-enhanced PSP images. Study Design: Twenty-four extracted posterior teeth with MOD inlay preparations were secured in models simulating a natural arrangement of teeth. Lesions were created in proximal boxes using dental burs of varying sizes. Defects were filled with wax and plaster and preparations were restored with composite or amalgam. Results: Averages of receiver operating curve areas (A(2)) revealed diagnostic performances of Az=0.74 for film, Az=0.80 for CCD, Az=0.73 for unenhanced PSP and Az=0.64 for enhanced PSP. The differences between these means were significant (MANOVA p <0.0001). Unenhanced PSP produced significantly poorer performance than other modalities. CCD performance was not significantly better than enhanced PSP. Lesions under radiopaque composite restorations were easier to detect, followed by those under amalgam and radiolucent composites across imaging modalities and lesion locations. Based on lesion location, those located at the buccal point angle were easiest to detect, followed by those at midgingival floor and lingual-point angle sites. Conclusions: Contrast and brightness-enhanced digital images enabled better signal detection and a comparable performance with film for detection of artificially induced recurrent caries.
引用
收藏
页码:223 / 230
页数:8
相关论文
共 50 条
  • [1] Diagnostic accuracy of enhanced digital images for caries detection.
    Kositbowornchai, S
    Basiw, H
    Promwang, Y
    Maragorn, H
    Sooksuntisakoonchai, N
    JOURNAL OF DENTAL RESEARCH, 2003, 82 : 658 - 658
  • [2] Comparison of Diagnostic Accuracy of Conventional Intraoral Periapical and Direct Digital Radiographs in Detecting Interdental Bone Loss
    Ashwinirani, S. R.
    Suragimath, Girish
    Jaishankar, H. P.
    Kulkarni, Prasad
    Bijjaragi, Shobha C.
    Sangle, Varsha Ajit
    JOURNAL OF CLINICAL AND DIAGNOSTIC RESEARCH, 2015, 9 (02) : ZC35 - ZC38
  • [3] Diagnostic accuracy of dental caries detection using ensemble techniques in deep learning with intraoral camera images
    Kang, Sohee
    Shon, Byungeun
    Park, Eun Young
    Jeong, Sungmoon
    Kim, Eun-Kyong
    PLOS ONE, 2024, 19 (09):
  • [4] Comparison of the diagnostic accuracy of direct digital radiography system, filtered images, and subtraction radiography
    Takeshita, Wilton Mitsunari
    Vessoni Iwaki, Lilian Cristina
    Da Silva, Marillani Cicarelli
    Iwaki Filho, Liogi
    Queiroz, Alfredo De Franco
    Gomes Geron, Lucas Bacfiegas
    CONTEMPORARY CLINICAL DENTISTRY, 2013, 4 (03) : 338 - 342
  • [5] A comparative evaluation of the diagnostic efficacy of film and digital sensors for detection of simulated periapical lesions
    Wallace, JA
    Nair, MK
    Colaco, MF
    Kapa, SF
    ORAL SURGERY ORAL MEDICINE ORAL PATHOLOGY ORAL RADIOLOGY AND ENDODONTICS, 2001, 92 (01): : 93 - 97
  • [6] Assessment of diagnostic accuracy of a direct digital radiographic-CMOS image with four types of filtered images for the detection of occlusal caries
    Sahu, Rohit Kumar
    Rajguru, Jagadish P.
    Pattnaiak, Naina
    Bardhan, Debajyoti
    Nayak, Bikash
    JOURNAL OF FAMILY MEDICINE AND PRIMARY CARE, 2020, 9 (01) : 206 - 214
  • [7] Diagnostic accuracy of film-based, TIFF, and wavelet compressed digital temporomandibular joint images
    Trapnell, CJ
    Scarfe, WC
    Cook, JH
    Silveira, AM
    Regennitter, FJ
    Haskell, BS
    JOURNAL OF DIGITAL IMAGING, 2000, 13 (01) : 38 - 45
  • [8] Diagnostic accuracy of film-based, TIFF, and wavelet compressed digital temporomandibular joint images
    Christopher J. Trapnell
    William C. Scarfe
    Jeff H. Cook
    Anibal M. Silveira
    Frederick J. Regennitter
    Bruce S. Haskell
    Journal of Digital Imaging, 2000, 13 : 38 - 45
  • [9] A Comparative Study on Diagnostic Accuracy of Colour Coded Digital Images, Direct Digital Images and Conventional Radiographs for Periapical Lesions - An In Vitro Study
    Pati, Abhishek Ranjan
    Mubeen
    Vijayalakshmi, K. R.
    Bhuyan, Sanat Kumar
    Panigrahi, Rajat G.
    Priyadarshini, Smita R.
    Misra, Satyaranjan
    Singh, Chandravir
    JOURNAL OF CLINICAL AND DIAGNOSTIC RESEARCH, 2014, 8 (11) : ZC55 - ZC59
  • [10] DIRECT MEASUREMENT OF EFFECT OF FILM MINIATURIZATION ON DIAGNOSTIC ACCURACY
    LEHR, JL
    LODWICK, GS
    FARRELL, C
    BRAATEN, MO
    VIRTAMA, P
    KOIVISTO, EL