Diagnostic accuracy of intraoral film and direct digital images for detection of simulated recurrent decay

被引:0
|
作者
Nair, MK
Ludlow, JB
May, KN
Nair, UP
Johnson, MP
Close, JM
机构
[1] Univ Pittsburgh, Sch Dent Med, Pittsburgh, PA 15261 USA
[2] Univ N Carolina, Sch Dent, Chapel Hill, NC USA
关键词
D O I
暂无
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
This study compared the diagnostic accuracy of bitewing images for detection of simulated recurrent caries using the following imaging modalities: Ektaspeed Plus film and different digital imaging system technologies comprised of a charge-coupled device (CCD) based digital imaging unit, a photo-stimulable phosphor (PSP) based unit and contrast-and brightness-enhanced PSP images. Study Design: Twenty-four extracted posterior teeth with MOD inlay preparations were secured in models simulating a natural arrangement of teeth. Lesions were created in proximal boxes using dental burs of varying sizes. Defects were filled with wax and plaster and preparations were restored with composite or amalgam. Results: Averages of receiver operating curve areas (A(2)) revealed diagnostic performances of Az=0.74 for film, Az=0.80 for CCD, Az=0.73 for unenhanced PSP and Az=0.64 for enhanced PSP. The differences between these means were significant (MANOVA p <0.0001). Unenhanced PSP produced significantly poorer performance than other modalities. CCD performance was not significantly better than enhanced PSP. Lesions under radiopaque composite restorations were easier to detect, followed by those under amalgam and radiolucent composites across imaging modalities and lesion locations. Based on lesion location, those located at the buccal point angle were easiest to detect, followed by those at midgingival floor and lingual-point angle sites. Conclusions: Contrast and brightness-enhanced digital images enabled better signal detection and a comparable performance with film for detection of artificially induced recurrent caries.
引用
收藏
页码:223 / 230
页数:8
相关论文
共 50 条
  • [11] Detection of Simulated Periapical Lesion in Intraoral Digital Radiography with Different Brightness and Contrast
    Gaeta-Araujo, Hugo
    Leandro Nascimento, Eduarda Helena
    Brasil, Danieli Moura
    Gomes, Amanda Farias
    Freitas, Deborah Queiroz
    De Oliveira-Santos, Christiano
    EUROPEAN ENDODONTIC JOURNAL, 2019, 4 (03): : 133 - 138
  • [12] Void detection in root fillings using intraoral analogue, intraoral digital and cone beam CT images
    Huybrechts, B.
    Bud, M.
    Bergmans, L.
    Lambrechts, P.
    Jacobs, R.
    INTERNATIONAL ENDODONTIC JOURNAL, 2009, 42 (08) : 675 - 685
  • [13] Approximal Caries Detection by DIFOTI: In Vitro Comparison of Diagnostic Accuracy/Efficacy with Film and Digital Radiography
    Astvaldsdottir, A.
    Ahlund, K.
    Holbrook, W. P.
    de Verdier, B.
    Tranaeus, S.
    INTERNATIONAL JOURNAL OF DENTISTRY, 2012, 2012
  • [14] Observer agreement in the detection of proximal caries with direct digital intraoral radiography
    Naitoh, M
    Yuasa, H
    Toyama, M
    Shiojima, M
    Nakamura, M
    Ushida, M
    Iida, H
    Hayashi, M
    Ariji, E
    ORAL SURGERY ORAL MEDICINE ORAL PATHOLOGY ORAL RADIOLOGY AND ENDODONTOLOGY, 1998, 85 (01): : 107 - 112
  • [15] Diagnostic accuracy of direct digital dental radiography for the detection of periapical bone lesions - Overall comparison between conventional and direct digital radiography
    Kullendorff, B
    Nilsson, M
    Rohlin, M
    ORAL SURGERY ORAL MEDICINE ORAL PATHOLOGY ORAL RADIOLOGY AND ENDODONTICS, 1996, 82 (03): : 344 - 350
  • [16] Periodontitis detection efficacy of film and digital images
    Nair, MK
    Ludlow, JB
    Tyndall, DA
    Platin, E
    Denton, G
    ORAL SURGERY ORAL MEDICINE ORAL PATHOLOGY ORAL RADIOLOGY AND ENDODONTICS, 1998, 85 (05): : 608 - 612
  • [17] Diagnostic accuracy of small volume cone beam computed tomography and intraoral periapical radiography for the detection of simulated external inflammatory root resorption
    Durack, C.
    Patel, S.
    Davies, J.
    Wilson, R.
    Mannocci, F.
    INTERNATIONAL ENDODONTIC JOURNAL, 2011, 44 (02) : 136 - 147
  • [18] Effects of different exposure values on diagnostic accuracy of digital images
    Pfeiffer, P
    Schmage, P
    Nergiz, I
    Platzer, U
    QUINTESSENCE INTERNATIONAL, 2000, 31 (04): : 257 - 260
  • [19] Lossy file compression and diagnostic image quality of digital intraoral radiographic images.
    VanderStelt, PP
    Sanderink, GCH
    Dula, K
    Huiskens, R
    JOURNAL OF DENTAL RESEARCH, 1997, 76 : 1010 - 1010
  • [20] The effects of restorative material and location on the detection of simulated recurrent caries. A comparison of dental film, direct digital radiography and tuned aperture computed tomography
    Nair, MK
    Tyndall, DA
    Ludlow, JB
    May, K
    Ye, F