Diagnostic accuracy of intraoral film and direct digital images for detection of simulated recurrent decay

被引:0
|
作者
Nair, MK
Ludlow, JB
May, KN
Nair, UP
Johnson, MP
Close, JM
机构
[1] Univ Pittsburgh, Sch Dent Med, Pittsburgh, PA 15261 USA
[2] Univ N Carolina, Sch Dent, Chapel Hill, NC USA
关键词
D O I
暂无
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
This study compared the diagnostic accuracy of bitewing images for detection of simulated recurrent caries using the following imaging modalities: Ektaspeed Plus film and different digital imaging system technologies comprised of a charge-coupled device (CCD) based digital imaging unit, a photo-stimulable phosphor (PSP) based unit and contrast-and brightness-enhanced PSP images. Study Design: Twenty-four extracted posterior teeth with MOD inlay preparations were secured in models simulating a natural arrangement of teeth. Lesions were created in proximal boxes using dental burs of varying sizes. Defects were filled with wax and plaster and preparations were restored with composite or amalgam. Results: Averages of receiver operating curve areas (A(2)) revealed diagnostic performances of Az=0.74 for film, Az=0.80 for CCD, Az=0.73 for unenhanced PSP and Az=0.64 for enhanced PSP. The differences between these means were significant (MANOVA p <0.0001). Unenhanced PSP produced significantly poorer performance than other modalities. CCD performance was not significantly better than enhanced PSP. Lesions under radiopaque composite restorations were easier to detect, followed by those under amalgam and radiolucent composites across imaging modalities and lesion locations. Based on lesion location, those located at the buccal point angle were easiest to detect, followed by those at midgingival floor and lingual-point angle sites. Conclusions: Contrast and brightness-enhanced digital images enabled better signal detection and a comparable performance with film for detection of artificially induced recurrent caries.
引用
收藏
页码:223 / 230
页数:8
相关论文
共 50 条
  • [31] Detection of simulated periodontal defects using cone-beam CT and digital intraoral radiography
    Bayat, Samaneh
    Talaeipour, Ahmad Reza
    Sarlati, Fatemeh
    DENTOMAXILLOFACIAL RADIOLOGY, 2016, 45 (06)
  • [32] Accuracy is in the eyes of the pathologist: The visual interpretive process and diagnostic accuracy with digital whole slide images
    Brunye, Tad T.
    Mercan, Ezgi
    Weaver, Donald L.
    Elmore, Joann G.
    JOURNAL OF BIOMEDICAL INFORMATICS, 2017, 66 : 171 - 179
  • [33] The accuracy of direct digital impressions of post spaces with different diameters and depths scanned by a wireless intraoral scanner
    Zhu, Jiakang
    Deng, Xianfeng
    Jin, Chunxiao
    Ma, Liya
    Huang, Cui
    JOURNAL OF DENTISTRY, 2025, 154
  • [34] Diagnostic Value and Reliability of Digital Images in the Detection of Infectious Microorganisms
    Haghighi, Mehrvash
    Bryce, Clare
    Hussein, Shafinaz
    Paulsen, John, Jr.
    Salib, Christian
    Veremis, Brandon
    Alialy, Roshanak
    Lahori, Mega
    Hao, Yansheng
    Liang, Yuanxin
    Szporn, Arnold
    Westra, William
    MODERN PATHOLOGY, 2022, 35 (SUPPL 2) : 1074 - 1074
  • [35] Diagnostic Value and Reliability of Digital Images in the Detection of Infectious Microorganisms
    Haghighi, Mehrvash
    Bryce, Clare
    Hussein, Shafinaz
    Paulsen, John, Jr.
    Salib, Christian
    Veremis, Brandon
    Alialy, Roshanak
    Lahori, Mega
    Hao, Yansheng
    Liang, Yuanxin
    Szporn, Arnold
    Westra, William
    LABORATORY INVESTIGATION, 2022, 102 (SUPPL 1) : 1074 - 1074
  • [36] Analysis of PlanetScope Dove Digital Surface Model Accuracy Using Geometrically Simulated Images
    Noh, Myoung-Jong
    Howat, Ian M.
    REMOTE SENSING, 2023, 15 (14)
  • [37] A comparison of the diagnostic accuracy of bitewing, periapical, unfiltered and filtered digital panoramic images for approximal caries detection in posterior teeth
    Akarslan, Z. Z.
    Akdevelioglu, M.
    Gungor, K.
    Erten, H.
    DENTOMAXILLOFACIAL RADIOLOGY, 2008, 37 (08) : 458 - 463
  • [38] Comparison of the diagnostic potential of direct digital and conventional intraoral radiography in the evaluation of peri-implant conditions
    Mörner-Svalling, AC
    Tronie, G
    Andersson, LG
    Welander, U
    CLINICAL ORAL IMPLANTS RESEARCH, 2003, 14 (06) : 714 - 719
  • [39] Comparison of diagnostic accuracy of film and digital tomograms for assessment of morphological changes in the TMJ
    Wiese, M.
    Hintze, H.
    Svensson, P.
    Wenzel, A.
    DENTOMAXILLOFACIAL RADIOLOGY, 2007, 36 (01) : 12 - 17
  • [40] Accuracy of Digital Images in the Detection of Marginal Micro leakage: An In Vitro Study
    de Santi Alvarenga, Fabio Augusto
    de Andrade, Marcelo Ferrarezi
    Pinelli, Camila
    Souza Rastelli, Alessanda Nara
    Victorino, Keli Regina
    Monteiro Loffredo, Leonor de Castro
    JOURNAL OF ADHESIVE DENTISTRY, 2012, 14 (04): : 335 - 338