Periodontitis detection efficacy of film and digital images

被引:22
|
作者
Nair, MK [1 ]
Ludlow, JB
Tyndall, DA
Platin, E
Denton, G
机构
[1] Univ Pittsburgh, Sch Dent Med, Dept Oral & Maxillofacial Radiol, Pittsburgh, PA 15261 USA
[2] Univ N Carolina, Sch Dent, Dept Diagnost Sci, Chapel Hill, NC USA
[3] Univ N Carolina, Sch Dent, Dept Oral Radiol, Chapel Hill, NC USA
关键词
D O I
10.1016/S1079-2104(98)90299-2
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Objective. The objective of this study was to evaluate the accuracy of alveolar crestal bone detection in a comparison of unenhanced and enhanced Sidexis (Siemens Medical Systems, inc., Bensheim, Germany) digital images with Ektaspeed Plus (Eastman Kodak, Rochester, N.Y.) films by means of receiver operating characteristic analysis. Study Design. More than 100 proximal and furcal areas in the anterior and posterior areas of the mandible and maxilla of each of three tissue-equivalent human skull phantoms were imaged with film, direct digital images, and contrast- and brightness-enhanced digital images. Alveolar crest status was assessed by a consensus panel of three experts who used the Delphi method and evaluated information from ail of the imaging modalities concurrently. Five observers assessed all images for the presence or absence of crestal bone loss using a five-point confidence scale. Receiver operating characteristic curves were generated, and calculated areas (A(Z)) were analyzed by means of analysis of variance. Results. The expert panel determined that of 106 crestal areas, 48 were disease free and 58 exhibited bone loss greater than 2 mm apical to the cemento-enamel junction. Analysis of variance of observer A, scores showed significant differences among readers (p < 0.001) and among readings (p = 0.027), but not among modalities (p = 0.435). Mean A(Z) values for the different modalities were as follows: Sidexis, 0.70; enhanced Sidexis, 0.71; Ektaspeed Plus films, 0.735. Conclusion, The Sidexis digital imaging system was not significantly different from Ektaspeed Plus film for crestal bone evaluation in this in vitro study.
引用
收藏
页码:608 / 612
页数:5
相关论文
共 50 条
  • [21] Evaluation of an Artificial Intelligence System for the Diagnosis of Apical Periodontitis on Digital Panoramic Images
    Icoz, D.
    Terzioglu, H.
    Ozel, M. A.
    Karakurt, R.
    NIGERIAN JOURNAL OF CLINICAL PRACTICE, 2023, 26 (08) : 1085 - 1090
  • [22] Deterioration detection for digital film restoration
    Buisson, O
    Besserer, B
    Boukir, S
    Helt, F
    1997 IEEE COMPUTER SOCIETY CONFERENCE ON COMPUTER VISION AND PATTERN RECOGNITION, PROCEEDINGS, 1997, : 78 - 84
  • [23] Efficacy of CPITN sextant scores for detection of periodontitis disease activity
    Rams, TE
    Listgarten, MA
    Slots, J
    JOURNAL OF CLINICAL PERIODONTOLOGY, 1996, 23 (04) : 355 - 361
  • [24] Film versus digital cinema: the evolution of moving images
    Tinker, M
    IMAGE AND VIDEO COMMUNICATIONS AND PROCESSING 2003, PTS 1 AND 2, 2003, 5022 : 14 - 23
  • [25] Pure Sensations? From Abstract Film to Digital Images
    Castello-Branco, Patricia
    ANIMATION-AN INTERDISCIPLINARY JOURNAL, 2010, 5 (01): : 25 - 40
  • [26] Locating film production sites with portable digital images
    Hamit, Francis
    Advanced Imaging, 2000, 15 (04) : 29 - 31
  • [27] Digital image resolution: Comparison to screen/film images
    Jones, J
    Bell, KA
    Bluth, EI
    RADIOLOGY, 2001, 221 : 121 - 121
  • [28] DIGITAL AND CONVENTIONAL CHEST IMAGES - OBSERVER PERFORMANCE WITH FILM DIGITAL RADIOGRAPHY SYSTEM
    GOODMAN, LR
    FOLEY, WD
    WILSON, CR
    RIMM, AA
    LAWSON, TL
    RADIOLOGY, 1986, 158 (01) : 27 - 33
  • [29] DETECTION OF BINARY IMAGES IN FILM GRAIN NOISE
    TAVILDAR, AS
    GUPTA, SN
    GUPTA, HM
    ELECTRONICS LETTERS, 1985, 21 (07) : 260 - 262
  • [30] Diagnostic efficacy or printed digital radiography images.
    Haymore, JA
    Gandara, B
    Day, J
    Hollender, L
    JOURNAL OF DENTAL RESEARCH, 2000, 79 : 376 - 376