Periodontitis detection efficacy of film and digital images

被引:22
|
作者
Nair, MK [1 ]
Ludlow, JB
Tyndall, DA
Platin, E
Denton, G
机构
[1] Univ Pittsburgh, Sch Dent Med, Dept Oral & Maxillofacial Radiol, Pittsburgh, PA 15261 USA
[2] Univ N Carolina, Sch Dent, Dept Diagnost Sci, Chapel Hill, NC USA
[3] Univ N Carolina, Sch Dent, Dept Oral Radiol, Chapel Hill, NC USA
关键词
D O I
10.1016/S1079-2104(98)90299-2
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Objective. The objective of this study was to evaluate the accuracy of alveolar crestal bone detection in a comparison of unenhanced and enhanced Sidexis (Siemens Medical Systems, inc., Bensheim, Germany) digital images with Ektaspeed Plus (Eastman Kodak, Rochester, N.Y.) films by means of receiver operating characteristic analysis. Study Design. More than 100 proximal and furcal areas in the anterior and posterior areas of the mandible and maxilla of each of three tissue-equivalent human skull phantoms were imaged with film, direct digital images, and contrast- and brightness-enhanced digital images. Alveolar crest status was assessed by a consensus panel of three experts who used the Delphi method and evaluated information from ail of the imaging modalities concurrently. Five observers assessed all images for the presence or absence of crestal bone loss using a five-point confidence scale. Receiver operating characteristic curves were generated, and calculated areas (A(Z)) were analyzed by means of analysis of variance. Results. The expert panel determined that of 106 crestal areas, 48 were disease free and 58 exhibited bone loss greater than 2 mm apical to the cemento-enamel junction. Analysis of variance of observer A, scores showed significant differences among readers (p < 0.001) and among readings (p = 0.027), but not among modalities (p = 0.435). Mean A(Z) values for the different modalities were as follows: Sidexis, 0.70; enhanced Sidexis, 0.71; Ektaspeed Plus films, 0.735. Conclusion, The Sidexis digital imaging system was not significantly different from Ektaspeed Plus film for crestal bone evaluation in this in vitro study.
引用
收藏
页码:608 / 612
页数:5
相关论文
共 50 条
  • [41] Hybrid Edge Detection Technique for Digital Images
    Chaudhary, Dev Kumar
    Lal, Roshan
    Kashyap, Nirbhay
    Choudhury, Tanupriya
    2016 IEEE INTERNATIONAL CONFERENCE ON COMPUTING, COMMUNICATION AND AUTOMATION (ICCCA), 2016, : 1116 - 1121
  • [42] Detection of microcalcification clusters in digital mammogram images
    McLoughlin, KJ
    Bones, PJ
    Kovesi, PD
    DIGITAL MAMMOGRAPHY, PROCEEDINGS, 2003, : 353 - 357
  • [43] Automatic Detection of Molecular markers in Digital Images
    Marcal, A. R. S.
    Caridade, C. M. R.
    Albuquerque, P.
    Mendes, M. V.
    Tavares, F.
    2009 ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY, VOLS 1-20, 2009, : 6710 - +
  • [44] Blind Forgery Detection in Digital Images: An Analysis
    Hebbar, Nagaveni
    Kunte, Ashwini
    INTELLIGENT COMPUTING, INFORMATION AND CONTROL SYSTEMS, ICICCS 2019, 2020, 1039 : 604 - 614
  • [45] RED LESIONS DETECTION IN DIGITAL FUNDUS IMAGES
    Balasubramanian, S.
    Pradhan, Sandip
    Chandrasekaran, V.
    2008 15TH IEEE INTERNATIONAL CONFERENCE ON IMAGE PROCESSING, VOLS 1-5, 2008, : 2932 - 2935
  • [46] Fast Parallel Blur Detection of Digital Images
    Giang Son Tran
    Thi Phuong Nghiem
    Nhat Quang Doan
    Alexis Drogoul
    Luong Chi Mai
    2016 IEEE RIVF INTERNATIONAL CONFERENCE ON COMPUTING & COMMUNICATION TECHNOLOGIES, RESEARCH, INNOVATION, AND VISION FOR THE FUTURE (RIVF), 2016, : 147 - 152
  • [47] Detection and Color Correction of Artifacts in Digital Images
    Bibikov, S. A.
    Zakharov, R. K.
    Nikonorov, A. V.
    Fursov, V. A.
    Yakimov, P. Yu.
    OPTOELECTRONICS INSTRUMENTATION AND DATA PROCESSING, 2011, 47 (03) : 226 - 232
  • [48] AN EFFICIENT ALGORITHM FOR EXTREMA DETECTION IN DIGITAL IMAGES
    CHAUDHURI, BB
    SHANKAR, BU
    PATTERN RECOGNITION LETTERS, 1989, 10 (02) : 81 - 85
  • [49] DIGITAL METHODS FOR CHANGE DETECTION IN SCINTIGRAPHIC IMAGES
    VENOT, A
    LEBRUCHEC, JF
    GOLMARD, JL
    ROUCAYROL, JC
    JOURNAL OF NUCLEAR MEDICINE, 1983, 24 (05) : P67 - P67
  • [50] Detection of digital forgeries using an image interpolation from digital images
    Yun, Yong-In
    Lee, Jung-Beom
    Jung, Da-un
    Har, Dong-Hwan
    Choi, Jong-Soo
    2008 IEEE INTERNATIONAL SYMPOSIUM ON CONSUMER ELECTRONICS, VOLS 1 AND 2, 2008, : 425 - +