Diffusion, ionization, and sampling processes in the glow discharge source for mass spectrometry

被引:30
|
作者
Hang, W [1 ]
Harrison, WW [1 ]
机构
[1] UNIV FLORIDA,DEPT CHEM,GAINESVILLE,FL 32611
关键词
D O I
10.1021/ac9710386
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A microsecond pulsed glow discharge source has been coupled to a quadrupole mass analyzer for plasma diagnostics. Diffusion times of sputtered atoms from the cathode surface to the sampling orifice are measured for different cathode-orifice distances, pressures, and powers. These measured times are found to be close to the values calculated from the theoretical models, indicating the suitability of this approach to describe the diffusion process in the glow discharge. By comparing ion signal profiles of the gaseous species and sputtered particles and the theoretical atom distributions, evidence is shown that most ions measured by the mass spectrometer are ionized in the vicinity of the orifice.
引用
收藏
页码:4957 / 4963
页数:7
相关论文
共 50 条
  • [21] Microplasma Discharge Ionization Source for Ambient Mass Spectrometry
    Symonds, Joshua M.
    Galhena, Asiri S.
    Fernandez, Facundo M.
    Orlando, Thomas M.
    ANALYTICAL CHEMISTRY, 2010, 82 (02) : 621 - 627
  • [22] Glow discharge mass spectrometry
    Hoffmann, V
    Kasik, M
    Robinson, PK
    Venzago, C
    ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2005, 381 (01) : 173 - 188
  • [23] Glow discharge mass spectrometry
    Volker Hoffmann
    Martin Kasik
    Peter K. Robinson
    Cornel Venzago
    Analytical and Bioanalytical Chemistry, 2005, 381 : 173 - 188
  • [24] Metal mesh sampling for glow discharge optical and mass spectrometry.
    Shaw, RW
    Barshick, CM
    Smith, DH
    Ramsey, JM
    ABSTRACTS OF PAPERS OF THE AMERICAN CHEMICAL SOCIETY, 2000, 220 : U23 - U23
  • [25] Glow discharge electron impact ionization source for miniature mass spectrometers
    Gao, Liang
    Song, Qingyu
    Noll, Robert J.
    Duncan, Jason
    Cooks, R. Graham
    Zheng Ouyang
    JOURNAL OF MASS SPECTROMETRY, 2007, 42 (05): : 675 - 680
  • [26] Development of a direct current gas sampling glow discharge ionization source for the time-of-flight mass spectrometer
    Guzowski, JP
    Broekaert, JAC
    Ray, SJ
    Hieftje, GM
    JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 1999, 14 (08) : 1121 - 1127
  • [27] Erratum to: Evaluation of the operating parameters of the liquid sampling-atmospheric pressure glow discharge (LS-APGD) ionization source for elemental mass spectrometry
    Lynn X. Zhang
    Benjamin T. Manard
    Stefanie Konegger-Kappel
    R. Kenneth Marcus
    Analytical and Bioanalytical Chemistry, 2014, 406 : 7741 - 7741
  • [28] RADIO-FREQUENCY POWERED GLOW-DISCHARGE ATOMIZATION IONIZATION SOURCE FOR SOLIDS MASS-SPECTROMETRY
    DUCKWORTH, DC
    MARCUS, RK
    ANALYTICAL CHEMISTRY, 1989, 61 (17) : 1879 - 1886
  • [29] Liquid sampling–atmospheric pressure glow discharge (LS-APGD) ionization source for elemental mass spectrometry: preliminary parametric evaluation and figures of merit
    C. Derrick Quarles
    Anthony J. Carado
    Charles J. Barinaga
    David W. Koppenaal
    R. Kenneth Marcus
    Analytical and Bioanalytical Chemistry, 2012, 402 : 261 - 268
  • [30] Excitation and ionization processes of chlorine in molybdenum dichloride dioxide flakes using the glow discharge mass spectrometry technique
    Mushtaq, Sohail
    Journal of Analytical Atomic Spectrometry, 2022, 37 (03): : 584 - 591