Glow discharge mass spectrometry

被引:137
|
作者
Hoffmann, V [1 ]
Kasik, M
Robinson, PK
Venzago, C
机构
[1] Leibniz Inst Solid State & Mat Res Dresden, D-01171 Dresden, Germany
[2] Shiva Technol Inc, Syracuse, NY 13211 USA
[3] Mass Spectrometry Int, Hanover Business Pk, Altrincham, Cheshire, England
[4] Degussa AG, D-63457 Hanau, Germany
关键词
glow discharge mass spectrometry; depth profile; temperature; fast flow; pulse;
D O I
10.1007/s00216-004-2933-2
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Over the past twenty years or so, glow discharge mass spectrometry (GDMS) has become the industry standard for the analysis of trace elements in metals and semiconductors. A review of its history is followed by a picture of the present situation and a look to where the future may lie. Applications are summarised, including the ability of GDMS to offer depth-resolved data and non-conductor analysis, and the well-documented quantitative nature of the results is reviewed. The effects resulting from the physical properties of the analyte material are discussed at length. Finally, recent work such as "fast flow" sources and pulsed glow discharges is reviewed.
引用
收藏
页码:173 / 188
页数:16
相关论文
共 50 条
  • [1] Glow discharge mass spectrometry
    Volker Hoffmann
    Martin Kasik
    Peter K. Robinson
    Cornel Venzago
    [J]. Analytical and Bioanalytical Chemistry, 2005, 381 : 173 - 188
  • [2] Analytical glow discharge mass spectrometry
    Ganeev, A. A.
    Gubal, A. R.
    Uskov, K. N.
    Potapov, S. V.
    [J]. RUSSIAN CHEMICAL BULLETIN, 2012, 61 (04) : 752 - 767
  • [3] Analytical glow discharge mass spectrometry
    A. A. Ganeev
    A. R. Gubal
    K. N. Uskov
    S. V. Potapov
    [J]. Russian Chemical Bulletin, 2012, 61 : 752 - 767
  • [4] An instrument for glow discharge mass spectrometry
    Jakubowski, N
    [J]. NACHRICHTEN AUS DER CHEMIE, 2003, 51 (11) : 1152 - 1155
  • [6] Comparative investigation on the characteristics of glow discharge plasma using glow discharge mass spectrometry and glow discharge optical emission spectrometry
    Wagatsuma, K
    Saka, T
    Yamaguchi, M
    Ito, K
    [J]. JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 2002, 17 (10) : 1359 - 1362
  • [7] Glow-discharge mass spectrometry (GDMS)
    Inokuma, Yasuo
    Endo, Jyo
    Morimoto, Masayuki
    [J]. Sumitomo Metals, 1996, 48 (02): : 98 - 102
  • [8] GLOW-DISCHARGE MASS-SPECTROMETRY
    HARRISON, WW
    HESS, KR
    MARCUS, RK
    KING, FL
    [J]. ANALYTICAL CHEMISTRY, 1986, 58 (02) : A341 - &
  • [9] GLOW-DISCHARGE MASS-SPECTROMETRY
    HARRISON, WW
    BENTZ, BL
    [J]. PROGRESS IN ANALYTICAL SPECTROSCOPY, 1988, 11 (01): : 53 - 110
  • [10] Determination of oxygen in magnesium by glow discharge mass spectrometry
    Kikuta, Emi
    Asano, Hiloshi
    Kikuchi, Tadashi
    [J]. TETSU TO HAGANE-JOURNAL OF THE IRON AND STEEL INSTITUTE OF JAPAN, 2007, 93 (02): : 128 - 131