Energy calibration of CsI(T1) scintillator in pulse-shape identification technique

被引:16
|
作者
Avdeichkov, V
Ghetti, R
Golubev, P
Jakobsson, B
Colonna, N
机构
[1] Lund Univ, Dept Phys, S-22100 Lund, Sweden
[2] Joint Inst Nucl Res, Dubna 141980, Russia
[3] Ist Nazl Fis Nucl, I-70126 Bari, Italy
关键词
inorganic scintillators; light ions response function; pulse-shape identification; calibration;
D O I
10.1016/S0168-9002(03)00625-9
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
A batch of 16 CsI(TI) scintillator crystals, supplied by the Bicron Company, has been studied with respect to precise energy calibration in pulse-shape identification technique. The light corresponding to pulse integration within the time interval 1.6-4.5 mus (long gate) and 0.0-4.5 mus (extra-long gate) exhibits a power law relation, L(E, Z, A) a1 (Z, A)Ea2(Z-4), for (1.2.3) H isotopes in the measured energy range 5-150 MeV. For the time interval 0.0-0.60 mus (short gate), a significant deviation from the power law relation is observed, for energy greater than similar to30 MeV. The character of the a2(p)-a2(d) and a2(p)-a2(t) correlations for protons, deuterons and tritons, reveals 3 types of crystals in the batch. These subbatches differ in the value of the extracted parameter a2 for protons, and in the value of the spread of a2 for deuterons and tritons. This may be explained by the difference in the energy dependence of the fast decay time component and/or by the difference in the light output ratio of the fast/slow components. An accuracy well inside 1.0% is achieved in the energy calibration of the CsI(TI) crystals by using the DeltaE(Si) E(CsI(Tl))/PMT method. The batch of 16 CsI(TI) crystals is utilized to measure the correlations of light charged particles produced in E/A = 61 MeV, (36)Arinduced reactions. The preliminary correlation functions for two protons with small relative momenta are presented. (C) 2003 Elsevier Science B.V. All rights reserved.
引用
下载
收藏
页码:505 / 513
页数:9
相关论文
共 50 条
  • [41] Limitations of the pulse-shape technique for particle discrimination in planar Si detectors
    Pausch, G
    Moszynski, M
    Bohne, W
    Cederkall, J
    Grawe, H
    Klamra, W
    Lampert, MO
    Rohr, P
    Schubart, R
    Seidel, W
    Wolski, D
    1996 IEEE NUCLEAR SCIENCE SYMPOSIUM - CONFERENCE RECORD, VOLS 1-3, 1997, : 687 - 691
  • [42] Limitations of the pulse-shape technique for particle discrimination in planar Si detectors
    Pausch, G
    Moszynski, M
    Bohne, W
    Cederkall, J
    Grawe, H
    Klamra, W
    Lampert, MO
    Rohr, P
    Schubart, R
    Seidel, W
    Wolski, D
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 1997, 44 (03) : 1040 - 1045
  • [43] PULSE SHAPE DISCRIMINATION OF HIGH-ENERGY NEUTRONS AND GAMMA-RAYS IN NAI(T1)
    KURFESS, JD
    SHARE, GH
    THEUS, RB
    BULLETIN OF THE AMERICAN PHYSICAL SOCIETY, 1975, 20 (04): : 562 - 562
  • [44] Absolute energy calibration with the neutron-activated liquid-source system at BaBar's CsI(T1) calorimeter
    Bauer, JA
    2003 IEEE NUCLEAR SCIENCE SYMPOSIUM, CONFERENCE RECORD, VOLS 1-5, 2004, : 31 - 35
  • [45] The CsI(T1) crystal detector in TEXONO low energy neutrino experiment
    Li, J
    Liu, Y
    Zhao, DX
    Mao, ZP
    Qiu, JF
    Xia, XM
    Lai, YF
    Sheng, HY
    Wang, PL
    Zhuang, BA
    Zhao, PP
    Feng, S
    Yue, Q
    Wong, HT
    Lai, WP
    Chen, CP
    Lee, SC
    Teng, PK
    Wang, SC
    Wang, CW
    Chang, CC
    Chang, CY
    Li, HB
    Chao, JH
    Liu, HM
    Tang, HQ
    Zhou, ZY
    Su, RF
    Liu, ZS
    Zhang, ZY
    HIGH ENERGY PHYSICS AND NUCLEAR PHYSICS-CHINESE EDITION, 2002, 26 (04): : 393 - 401
  • [46] DEPENDENCE OF LIGHT OUTPUT OF A CSI(T1) CRYSTAL ON ENERGY OF PROTONS AND DEUTERONS
    TSIRLIN, YA
    ZALYUBOV.II
    SOKOLOVS.TI
    NEZNAMOV, VG
    NIKULINA, RA
    INSTRUMENTS AND EXPERIMENTAL TECHNIQUES-USSR, 1965, (03): : 709 - &
  • [47] CsI(T1) crystal detector in TEXONO low energy neutrino experiment
    Li, Jin
    Liu, Yan
    Zhao, Di-Xin
    Mao, Ze-Pu
    Qiu, Jin-Fa
    Xia, Xiao-Mi
    Lai, Yuan-Fen
    Sheng, Hua-Yi
    Wang, Pei-Liang
    Zhuang, Bao-An
    Zhao, Ping-Ping
    Shi, Feng
    Yue, Qian
    Tang, Hong-Qing
    Zhou, Zu-Ying
    Liu, Zheng-Shan
    Zhang, Zhi-Yong
    Wong, H.T.
    Lai, W.P.
    Chen, C.P.
    Lee, S.C.
    Teng, P.K.
    Wang, S.C.
    Wang, C.W.
    Chang, C.C.
    Chang, C.Y.
    Li, H.B.
    Chao, J.H.
    Liu, H.M.
    Su, R.F.
    Kao Neng Wu Li Yu Ho Wu Li/High Energy Physics and Nuclear Physics, 2002, 26 (04):
  • [48] PARTICLE SELECTION IN CRYSTALS OF CSI(T1)
    ROBERTSON, JC
    WARD, A
    PROCEEDINGS OF THE PHYSICAL SOCIETY OF LONDON, 1959, 73 (471): : 523 - 525
  • [49] TOTAL EFFICIENCIES PHOTOFRACTIONS AND PHOTOEFFICIENCIES OF NAI(T1) AND CSI(T1) CRYSTALS
    VARTANOV, NA
    SAMOILOV, PS
    INSTRUMENTS AND EXPERIMENTAL TECHNIQUES-USSR, 1965, (02): : 310 - &
  • [50] FLUORESCENT RESPONSE OF NAI(T1) CSI(T1) CSI(NA) AND CAF2(EU) TO X-RAYS AND LOW ENERGY GAMMA RAYS
    AITKEN, DW
    BERON, BL
    YENICAY, G
    ZULLIGER, HR
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 1967, NS14 (01) : 468 - +