Energy calibration of CsI(T1) scintillator in pulse-shape identification technique

被引:16
|
作者
Avdeichkov, V
Ghetti, R
Golubev, P
Jakobsson, B
Colonna, N
机构
[1] Lund Univ, Dept Phys, S-22100 Lund, Sweden
[2] Joint Inst Nucl Res, Dubna 141980, Russia
[3] Ist Nazl Fis Nucl, I-70126 Bari, Italy
关键词
inorganic scintillators; light ions response function; pulse-shape identification; calibration;
D O I
10.1016/S0168-9002(03)00625-9
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
A batch of 16 CsI(TI) scintillator crystals, supplied by the Bicron Company, has been studied with respect to precise energy calibration in pulse-shape identification technique. The light corresponding to pulse integration within the time interval 1.6-4.5 mus (long gate) and 0.0-4.5 mus (extra-long gate) exhibits a power law relation, L(E, Z, A) a1 (Z, A)Ea2(Z-4), for (1.2.3) H isotopes in the measured energy range 5-150 MeV. For the time interval 0.0-0.60 mus (short gate), a significant deviation from the power law relation is observed, for energy greater than similar to30 MeV. The character of the a2(p)-a2(d) and a2(p)-a2(t) correlations for protons, deuterons and tritons, reveals 3 types of crystals in the batch. These subbatches differ in the value of the extracted parameter a2 for protons, and in the value of the spread of a2 for deuterons and tritons. This may be explained by the difference in the energy dependence of the fast decay time component and/or by the difference in the light output ratio of the fast/slow components. An accuracy well inside 1.0% is achieved in the energy calibration of the CsI(TI) crystals by using the DeltaE(Si) E(CsI(Tl))/PMT method. The batch of 16 CsI(TI) crystals is utilized to measure the correlations of light charged particles produced in E/A = 61 MeV, (36)Arinduced reactions. The preliminary correlation functions for two protons with small relative momenta are presented. (C) 2003 Elsevier Science B.V. All rights reserved.
引用
下载
收藏
页码:505 / 513
页数:9
相关论文
共 50 条
  • [31] APPLICATION OF PULSE-SHAPE DISCRIMINATION TECHNIQUE TO IMPROVE THE ENERGY RESOLUTION OF A GAS SCINTILLATION PROPORTIONAL COUNTER
    GARG, SP
    MURTHY, KBS
    SHARMA, RC
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1993, 336 (1-2): : 200 - 205
  • [32] COMPARATIVE CHARACTERISTICS OF NAI(T1) AND CSI(T1) DETECTORS
    SOBORNOV, OP
    SHCHEGLOV, OP
    SOVIET ATOMIC ENERGY, 1975, 39 (01): : 640 - 642
  • [33] Breakthrough in pulse-shape based particle identification with silicon detectors
    Mutterer, M
    Trzaska, WH
    Tyurin, GP
    Evsenin, AV
    von Kalben, J
    Kemmer, J
    Kapusta, M
    Lyapin, VG
    Khlebnikov, SV
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 2000, 47 (03) : 756 - 759
  • [34] Breakthrough in pulse-shape based particle identification with silicon detectors
    Mutterer, M
    Trzaska, WH
    Tyurin, GP
    Evsenin, AV
    von Kalben, J
    Kemmer, J
    Kapusta, M
    Lyapin, VG
    Khlebnikov, SV
    1999 IEEE NUCLEAR SCIENCE SYMPOSIUM - CONFERENCE RECORD, VOLS 1-3, 1999, : 148 - 151
  • [35] Breakthrough in pulse-shape based particle identification with silicon detectors
    Mutterer, M.
    Trzaska, W.H.
    Tyurin, G.P.
    Evsenin, A.V.
    von Kalben, J.
    Kemmer, J.
    Kapusta, M.
    Lyapin, V.G.
    Khlebnikov, S.V.
    IEEE Transactions on Nuclear Science, 2000, 47 (3 II) : 756 - 759
  • [36] Pulse-shape analysis for identification of low-energy particles by using a silicon pad detector
    Lee, K. W.
    Jung, H. S.
    Kwon, Y. K.
    Lee, J. H.
    Lee, C. S.
    JOURNAL OF THE KOREAN PHYSICAL SOCIETY, 2008, 53 (02) : 1197 - 1200
  • [37] TEMPERATURE DEPENDENCE OF SCINTILLATION RESPONSE IN NAI(T1) KI(T1) CSI(T1)
    ALUKER, ED
    PHYSICS LETTERS, 1965, 14 (01): : 17 - &
  • [38] Light collection and pulse-shape discrimination in elongated scintillator cells for the PROSPECT reactor antineutrino experiment
    Ashenfelter, J.
    Balantekin, B.
    Band, H. R.
    Barclay, G.
    Bass, C. D.
    Berish, D.
    Bowden, N. S.
    Bowes, A.
    Brodsky, J. P.
    Bryan, C. D.
    Cherwinka, J. J.
    Chu, R.
    Classen, T.
    Commeford, K.
    Davee, D.
    Dean, D.
    Deichert, G.
    Diwan, M. V.
    Dolinski, M. J.
    Dolph, J.
    Dwyer, D. A.
    Gaison, J. K.
    Galindo-Uribarri, A.
    Gilje, K.
    Glenn, A.
    Goddard, B. W.
    Green, M.
    Han, K.
    Hans, S.
    Heeger, K. M.
    Heffron, B.
    Jaffe, D. E.
    Langford, T. J.
    Littlejohn, B. R.
    Caicedo, D. A. Martinez
    McKeown, R. D.
    Mendenhall, M. P.
    Mueller, P.
    Mumm, H. P.
    Napolitano, J.
    Neilson, R.
    Norcini, D.
    Pushin, D.
    Qian, X.
    Romero, E.
    Rosero, R.
    Saldana, L.
    Seilhan, B. S.
    Sharma, R.
    Sheets, S.
    JOURNAL OF INSTRUMENTATION, 2015, 10
  • [39] TIME-DOMAIN ENERGY MAXIMIZATION OF THE NYQUIST PULSE-SHAPE
    HASSAN, EE
    INTERNATIONAL JOURNAL OF ELECTRONICS, 1994, 76 (02) : 213 - 219
  • [40] Improvement of Time Resolution of BaF2 Scintillator for Low-Energy Gamma Rays by Digital Pulse-Shape Method
    Cho, Hwa Youn
    Lee, Ju Hahn
    Lee, Chun Sik
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 2010, 57 (03) : 1386 - 1390