Energy calibration of CsI(T1) scintillator in pulse-shape identification technique

被引:16
|
作者
Avdeichkov, V
Ghetti, R
Golubev, P
Jakobsson, B
Colonna, N
机构
[1] Lund Univ, Dept Phys, S-22100 Lund, Sweden
[2] Joint Inst Nucl Res, Dubna 141980, Russia
[3] Ist Nazl Fis Nucl, I-70126 Bari, Italy
关键词
inorganic scintillators; light ions response function; pulse-shape identification; calibration;
D O I
10.1016/S0168-9002(03)00625-9
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
A batch of 16 CsI(TI) scintillator crystals, supplied by the Bicron Company, has been studied with respect to precise energy calibration in pulse-shape identification technique. The light corresponding to pulse integration within the time interval 1.6-4.5 mus (long gate) and 0.0-4.5 mus (extra-long gate) exhibits a power law relation, L(E, Z, A) a1 (Z, A)Ea2(Z-4), for (1.2.3) H isotopes in the measured energy range 5-150 MeV. For the time interval 0.0-0.60 mus (short gate), a significant deviation from the power law relation is observed, for energy greater than similar to30 MeV. The character of the a2(p)-a2(d) and a2(p)-a2(t) correlations for protons, deuterons and tritons, reveals 3 types of crystals in the batch. These subbatches differ in the value of the extracted parameter a2 for protons, and in the value of the spread of a2 for deuterons and tritons. This may be explained by the difference in the energy dependence of the fast decay time component and/or by the difference in the light output ratio of the fast/slow components. An accuracy well inside 1.0% is achieved in the energy calibration of the CsI(TI) crystals by using the DeltaE(Si) E(CsI(Tl))/PMT method. The batch of 16 CsI(TI) crystals is utilized to measure the correlations of light charged particles produced in E/A = 61 MeV, (36)Arinduced reactions. The preliminary correlation functions for two protons with small relative momenta are presented. (C) 2003 Elsevier Science B.V. All rights reserved.
引用
下载
收藏
页码:505 / 513
页数:9
相关论文
共 50 条
  • [1] OPTIMIZATION OF CSI PULSE-SHAPE PARTICLE IDENTIFICATION METHOD
    GUSEV, AA
    PANASYUK, MI
    PUGACHEVA, GI
    MIKHAELI, L
    SHALIGA, Y
    VESTNIK MOSKOVSKOGO UNIVERSITETA SERIYA 3 FIZIKA ASTRONOMIYA, 1989, 30 (06): : 12 - 17
  • [2] IMPROVED PARTICLE SEPARATION WITH PULSE-SHAPE DISCRIMINATION IN CASE OF A CSI(TI) SCINTILLATOR
    MATHE, G
    NUCLEAR INSTRUMENTS & METHODS, 1966, 39 (02): : 356 - +
  • [3] PULSE-SHAPE DISCRIMINATION WITH A GLASS SCINTILLATOR
    COCEVA, C
    NUCLEAR INSTRUMENTS & METHODS, 1963, 21 (01): : 93 - 96
  • [4] Comparison of pulse shape discrimination methods for phoswich and CsI:T1 detectors
    Chandrikamohan, Pramoth
    DeVol, Timothy A.
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 2007, 54 (02) : 398 - 403
  • [5] INVESTIGATION OF THE PERFORMANCE OF CSI(TL) FOR CHARGED-PARTICLE IDENTIFICATION BY PULSE-SHAPE ANALYSIS
    BENRACHI, F
    CHAMBON, B
    CHEYNIS, B
    DRAIN, D
    PASTOR, C
    SEGHIER, D
    ZAID, K
    GIORNI, A
    HEUER, D
    LLERES, A
    MORAND, C
    STASSI, P
    VIANO, JB
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1989, 281 (01): : 137 - 142
  • [6] Pulse-shape discrimination and energy resolution of a liquid-argon scintillator with xenon doping
    Wahl, C. G.
    Bernard, E. P.
    Lippincott, W. H.
    Nikkel, J. A.
    Shin, Y.
    McKinsey, D. N.
    JOURNAL OF INSTRUMENTATION, 2014, 9
  • [7] Distance metrics for digital pulse-shape discrimination of scintillator detectors
    Alharbi, T.
    RADIATION PHYSICS AND CHEMISTRY, 2019, 156 : 205 - 209
  • [8] INCREASING EFFICIENCY OF COINCIDENCES AND ANTICOINCIDENCES IN WORKING WITH A CSI (T1) SCINTILLATOR
    BYSTRITS.VM
    OGANESYA.KO
    OMELYANE.MN
    ERMOLOV, PF
    FILCHENK.VV
    POROKHOV.SY
    DZHELEPO.VP
    INSTRUMENTS AND EXPERIMENTAL TECHNIQUES-USSR, 1971, 14 (04): : 1047 - &
  • [9] Polystyrene-based scintillator with pulse-shape discrimination capability
    Zhmurin, P. N.
    Lebedev, V. N.
    Titskaya, V. D.
    Adadurov, A. F.
    Elyseev, D. A.
    Pereymak, V. N.
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2014, 761 : 92 - 98
  • [10] ORGANIC-SCINTILLATOR PULSE-SHAPE DISCRIMINATOR SIGNATURES ASSOCIATED WITH HIGH-ENERGY NEUTRONS
    ONGE, RS
    GALONSKY, A
    JOLLY, RK
    AMOS, TM
    NUCLEAR INSTRUMENTS & METHODS, 1975, 126 (03): : 391 - 395