A simple dendrimer-aptamer based microfluidic platform for E. coli O157:H7 detection and signal intensification by rolling circle amplification

被引:60
|
作者
Jiang, Yuqian [1 ,2 ]
Zou, Shan [2 ]
Cao, Xudong [1 ]
机构
[1] Univ Ottawa, Dept Chem & Biol Engn, 161 Louis Pasteur, Ottawa, ON K1N 6N5, Canada
[2] Natl Res Council Canada, Measurement Sci & Stand, 100 Sussex Dr, Ottawa, ON K1A 0R6, Canada
基金
加拿大自然科学与工程研究理事会;
关键词
Signal amplification; Lab-on-a-chip; Microfluidic device; Dendrimer; Aptamer; AFM; LATERAL FLOW BIOSENSOR; A-CHIP DEVICES; UNITED-STATES; FOODBORNE PATHOGENS; SALMONELLA; FOOD; PROTEIN; DNA; DIAGNOSTICS; STRATEGY;
D O I
10.1016/j.snb.2017.05.146
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
The majority of foodborne illnesses and deaths are caused by pathogenic bacteria. Therefore there is an increasingly urgent need for rapid, sensitive and cost-effective detection methods in order to avoid or to respond to outbreaks of such diseases in a timely manner. In an attempt to develop a simple and sensitive fluorescence intensity based microfluidic detection platform, PAMAM dendrimer was immobilized onto PDMS microchannel that was further modified with DNA aptamers for detections of E. coli O157:H7 cells. To further improve detection performance, rolling circle amplification (RCA) was employed to enhance the fluorescence signals. In addition, RCA products were characterized by both agarose gel electrophoresis and atomic force microscopy. Our results showed that RCA was able to enhance detection signals by up to 50 times and that the limit of detection of the system was reduced to 10(2) cells/mL with excellent detection specificities. Therefore, it can be concluded that this simple dendrimer-aptamer based microfluidic detection platform with RCA signal enhancement is a promising method for rapid and sensitive detection for foodborne pathogenic bacteria. (C) 2017 Elsevier B.V. All rights reserved.
引用
收藏
页码:976 / 984
页数:9
相关论文
共 50 条
  • [41] Developing a dual-RCA microfluidic platform for sensitive E. coli O157:H7 whole-cell detections
    Jiang, Yuqian
    Qiu, Zhenyu
    Le, Tao
    Zou, Shan
    Cao, Xudong
    ANALYTICA CHIMICA ACTA, 2020, 1127 (1127) : 79 - 88
  • [42] Evaluation of Lactic Acid as an Initial and Secondary Subprimal Intervention for Escherichia coli O157:H7, Non-O157 Shiga Toxin-Producing E. coli, and a Nonpathogenic E. coli Surrogate for E. coli O157:H7
    Pittman, C. I.
    Geornaras, I.
    Woerner, D. R.
    Nightingale, K. K.
    Sofos, J. N.
    Goodridge, L.
    Belk, K. E.
    JOURNAL OF FOOD PROTECTION, 2012, 75 (09) : 1701 - 1708
  • [43] MAGNETIC NANOPARTICLE BASED MAGNETOPHORESIS FOR EFFICIENT SEPARATION OF E. COLI O157:H7
    Huang, H.
    Ruan, C.
    Lin, J.
    Li, M.
    Cooney, L. M.
    Oliver, W. F.
    Li, Y.
    Wang, A.
    TRANSACTIONS OF THE ASABE, 2011, 54 (03) : 1015 - 1024
  • [44] Reveal® E. coli 2.0 Method for Detection of Escherichia coli O157:H7 in Raw Beef
    Hoerner, Rebecca
    Feldpausch, Jill
    Gray, R. Lucas
    Curry, Stephanie
    Lewis, Paul
    Tolan, Jerry
    Goldy, Tim
    Klein, Frank
    Neiditch, Barry
    Hosking, Edan
    Norton, Paul
    Rice, Jennifer
    Mozola, Mark
    Chen, Yi
    Brodsky, Michael
    Ziemer, Wayne
    JOURNAL OF AOAC INTERNATIONAL, 2011, 94 (06) : 1835 - 1845
  • [45] Low concentration E. coli O157:H7 bacteria sensing using microfluidic MEMS biosensor
    Dastider, Shibajyoti Ghosh
    Abdullah, Amjed
    Jasim, Ibrahem
    Yuksek, Nuh S.
    Dweik, Majed
    Almasri, Mahmoud
    REVIEW OF SCIENTIFIC INSTRUMENTS, 2018, 89 (12):
  • [46] Binding Characteristics Study of DNA based Aptamers for E. coli O157:H7
    Siddiqui, Saika
    Yuan, Jie
    MOLECULES, 2021, 26 (01):
  • [47] QCM immunosensor with nanoparticle amplification for detection of Escherichia coli O157:H7
    Fei Liu
    Yanbin Li
    Xiao-Li Su
    Michael F. Slavik
    Yibin Ying
    Jianping Wang
    Sensing and Instrumentation for Food Quality and Safety, 2007, 1 (4): : 161 - 168
  • [48] dA Tetrahedral DNA Nanostructures-based Microfluidic Platform for Detection of Pathogenic Escherichia Coli O157: H7
    Zhu, Fu-Lin
    Bian, Xiao-Jun
    Tian, Run
    Li, Liang
    Yan, Juan
    Liu, Gang
    CHINESE JOURNAL OF ANALYTICAL CHEMISTRY, 2020, 48 (04) : 473 - 483
  • [49] A sensitive lateral flow biosensor for Escherichia coli O157:H7 detection based on aptamer mediated strand displacement amplification
    Wu, Wei
    Zhao, Shiming
    Mao, Yiping
    Fang, Zhiyuan
    Lu, Xuewen
    Zeng, Lingwen
    ANALYTICA CHIMICA ACTA, 2015, 861 : 62 - 68
  • [50] Detection and enumeration of E. coli O157:H7 in water samples by culture and molecular methods
    Ngwa, G. A.
    Schop, R.
    Weir, S.
    Leon-Velarde, C. G.
    Odumeru, J. A.
    JOURNAL OF MICROBIOLOGICAL METHODS, 2013, 92 (02) : 164 - 172