A simple dendrimer-aptamer based microfluidic platform for E. coli O157:H7 detection and signal intensification by rolling circle amplification

被引:60
|
作者
Jiang, Yuqian [1 ,2 ]
Zou, Shan [2 ]
Cao, Xudong [1 ]
机构
[1] Univ Ottawa, Dept Chem & Biol Engn, 161 Louis Pasteur, Ottawa, ON K1N 6N5, Canada
[2] Natl Res Council Canada, Measurement Sci & Stand, 100 Sussex Dr, Ottawa, ON K1A 0R6, Canada
基金
加拿大自然科学与工程研究理事会;
关键词
Signal amplification; Lab-on-a-chip; Microfluidic device; Dendrimer; Aptamer; AFM; LATERAL FLOW BIOSENSOR; A-CHIP DEVICES; UNITED-STATES; FOODBORNE PATHOGENS; SALMONELLA; FOOD; PROTEIN; DNA; DIAGNOSTICS; STRATEGY;
D O I
10.1016/j.snb.2017.05.146
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
The majority of foodborne illnesses and deaths are caused by pathogenic bacteria. Therefore there is an increasingly urgent need for rapid, sensitive and cost-effective detection methods in order to avoid or to respond to outbreaks of such diseases in a timely manner. In an attempt to develop a simple and sensitive fluorescence intensity based microfluidic detection platform, PAMAM dendrimer was immobilized onto PDMS microchannel that was further modified with DNA aptamers for detections of E. coli O157:H7 cells. To further improve detection performance, rolling circle amplification (RCA) was employed to enhance the fluorescence signals. In addition, RCA products were characterized by both agarose gel electrophoresis and atomic force microscopy. Our results showed that RCA was able to enhance detection signals by up to 50 times and that the limit of detection of the system was reduced to 10(2) cells/mL with excellent detection specificities. Therefore, it can be concluded that this simple dendrimer-aptamer based microfluidic detection platform with RCA signal enhancement is a promising method for rapid and sensitive detection for foodborne pathogenic bacteria. (C) 2017 Elsevier B.V. All rights reserved.
引用
收藏
页码:976 / 984
页数:9
相关论文
共 50 条
  • [21] A sensitive electrochemical strategy via multiple amplification reactions for the detection of E. coli O157: H7
    Li, Yan
    Liu, Huamin
    Huang, Hui
    Deng, Jun
    Fang, Lichao
    Luo, Jing
    Zhang, Shu
    Huang, Jian
    Liang, Wenbin
    Zheng, Junsong
    BIOSENSORS & BIOELECTRONICS, 2020, 147
  • [22] Evaluation of the GENE-UP VR E. Coli O157:H7 method for the detection of E. coli O157:H7 in select foods: Collaborative study, 2019.03
    Johnson R.
    Mills J.
    Pittet J.-L.
    Rannou M.
    Bird P.
    Nelson M.
    Journal of AOAC International, 2021, 103 (05) : 1338 - 1347
  • [23] Sharp Transition in the Immunoimmobilization of E. coli O157:H7
    Celikkol-Aydin, Sukriye
    Suo, Zhiyong
    Yang, Xinghong
    Ince, Bahar
    Avci, Recep
    LANGMUIR, 2014, 30 (26) : 7755 - 7761
  • [24] An Aptamer-Based Biosensor for Colorimetric Detection of Escherichia coli O157: H7
    Wu, Wenhe
    Zhang, Jie
    Zheng, Meiqin
    Zhong, Yuhong
    Yang, Jie
    Zhao, Yuhong
    Wu, Wenping
    Ye, Wei
    Wen, Jie
    Wang, Qi
    Lu, Jianxin
    PLOS ONE, 2012, 7 (11):
  • [25] A systemic vaccine based on Escherichia coli O157:H7 bacterial ghosts (BGs) reduces the excretion of E. coli O157:H7 in calves
    Vilte, D. A.
    Larzabal, M.
    Mayr, U. B.
    Garbaccio, S.
    Gammella, M.
    Rabinovitz, B. C.
    Delgado, F.
    Meikle, V.
    Cantet, R. J. C.
    Lubitz, P.
    Lubitz, W.
    Cataldi, A.
    Mercado, E. C.
    VETERINARY IMMUNOLOGY AND IMMUNOPATHOLOGY, 2012, 146 (02) : 169 - 176
  • [26] Detection of Pathogenic E. coli O157:H7 by a Hybrid Microfluidic SPR and Molecular Imaging Cytometry Device
    Zordan, Michael D.
    Grafton, Meggie M. G.
    Acharya, Ghanashyam
    Reece, Lisa M.
    Cooper, Christy L.
    Aronson, Arthur I.
    Park, Kinam
    Leary, James F.
    CYTOMETRY PART A, 2009, 75A (02) : 155 - 162
  • [27] An Anti E. Coli O157:H7 Antibody-Immobilized Microcantilever for the Detection of Escherichia Coli (E. coli)
    Jing Zhang
    Hai-Feng Ji
    Analytical Sciences, 2004, 20 : 585 - 587
  • [28] Sensitive Chemiluminescence Immunoassay for E. coli O157:H7 Detection with Signal Dual-Amplification Using Glucose Oxidase and Laccase
    Zhag, Yun
    Tan, Chen
    Fei, Ruihua
    Liu, Xiaoxiao
    Zhou, Yuan
    Chen, Jing
    Chen, Huanchun
    Zhou, Rui
    Hu, Yonggang
    ANALYTICAL CHEMISTRY, 2014, 86 (02) : 1115 - 1122
  • [29] A micromachined impedance biosensor for accurate and rapid detection of E. coli O157:H7
    Dastider, Shibajyoti Ghosh
    Barizuddin, Syed
    Dweik, Majed
    Almasri, Mahmoud
    RSC ADVANCES, 2013, 3 (48): : 26297 - 26306
  • [30] Indirect immunofluorescence detection of E. coli O157:H7 with fluorescent silica nanoparticles
    Chen, Ze-Zhong
    Cai, Li
    Chen, Min-Yan
    Lin, Yi
    Pang, Dai-Wen
    Tang, Hong-Wu
    BIOSENSORS & BIOELECTRONICS, 2015, 66 : 95 - 102