Effects of abutment screw preload in two implant connection systems: A 3D finite element study

被引:7
|
作者
Jung, Won-kyung [1 ,2 ]
Lee, Won-sup [3 ,4 ]
Kwon, Ho-Beom [1 ,2 ]
机构
[1] Seoul Natl Univ, Sch Dent, Dent Res Inst, 101 Daehak Ro, Seoul 110744, South Korea
[2] Seoul Natl Univ, Sch Dent, Dept Prosthodont, 101 Daehak Ro, Seoul 110744, South Korea
[3] Seoul Natl Univ, Grad Sch Dent, Dept Prosthodont, Seoul, South Korea
[4] Catholic Univ Korea, Dent Hosp, Dept Prosthodont, St Marys Hosp, Seoul, South Korea
来源
JOURNAL OF PROSTHETIC DENTISTRY | 2019年 / 122卷 / 05期
基金
新加坡国家研究基金会;
关键词
STRESS-DISTRIBUTION; LOADING CONDITIONS; BONE;
D O I
10.1016/j.prosdent.2019.04.025
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Statement of problem. Finite element analysis (FEA) has been used to evaluate the biomechanical behaviors of dental implants. However, in some FEA studies, the influence of the preload condition has been omitted to simplify the analysis. This might affect the results of biomechanical analysis significantly. The preload condition requires analysis. Purpose. The purpose of this FEA study was to evaluate and verify the effects of the presence of the preload condition on abutment screws under the occlusal load for external and internal hexagonal connection systems. Material and method. The finite element models consisting of bone blocks, 2 different implant systems (Osstem US and GS system; Osstem Implant Co), and crowns were created. With these components, a total of 6 models with different conditions were constructed for FEA: external hexagonal connection system only with preload (E0), external hexagonal connection system with no preload but occlusal load (EN), external hexagonal system with both preload and occlusal load (EP), internal hexagonal system only with preload (10), internal hexagonal system with no preload but occlusal load (IN), and internal hexagonal system with both preload and occlusal load (IP). An 113-degree oblique load (100 N) to the axis of the implant was applied on the occlusal surface of the crown for the models with occlusal load. A preload of 825 N was applied in the abutment screw of the models EO, EP, IO, and IP. The maximum von Mises stress, maximum principal stress, and maximum displacement of the components of the models were evaluated. Results. Both external and internal connection systems resulted in higher maximum von Mises stress and maximum principal stress values in the presence of preload in the abutment screw. The internal connection system showed higher displacement values than the external system with or without occlusal loading, and values tended to increase with the preload condition. Conclusion. The presence of a preload condition significantly affected the biomechanical behaviors of the components of 2 different connection systems. The preload condition should be included in FEA to achieve more realistic results.
引用
收藏
页码:474.e1 / 474.e8
页数:8
相关论文
共 50 条
  • [1] Effects of Abutment Screw Coating on Implant Preload
    Park, Jae-Kyoung
    Choi, Jin-Uk
    Jeon, Young-Chan
    Choi, Kyung-Soo
    Jeong, Chang-Mo
    JOURNAL OF PROSTHODONTICS-IMPLANT ESTHETIC AND RECONSTRUCTIVE DENTISTRY, 2010, 19 (06): : 458 - 464
  • [2] Biomechanical Evaluation of the Effects of Implant Neck Wall Thickness and Abutment Screw Size: A 3D Nonlinear Finite Element Analysis
    Jeng, Ming-Dih
    Lin, Yang-Sung
    Lin, Chun-Li
    APPLIED SCIENCES-BASEL, 2020, 10 (10):
  • [3] Effects of Screw Configuration on the Preload Force of Implant-Abutment Screws
    Zipprich, Holger
    Rathe, Florian
    Pinz, Soeren
    Schlotmann, Luca
    Lauer, Hans-Christoph
    Ratka, Christoph
    INTERNATIONAL JOURNAL OF ORAL & MAXILLOFACIAL IMPLANTS, 2018, 33 (02) : E25 - E32
  • [4] Implant-abutment screw joint preload of 7 hex-top abutment systems
    Tan, KB
    Nicholls, JI
    INTERNATIONAL JOURNAL OF ORAL & MAXILLOFACIAL IMPLANTS, 2001, 16 (03) : 367 - 377
  • [5] In Vitro Study of Preload Loss in Different Implant Abutment Connection Designs
    Vinhas, Ana Sofia
    Aroso, Carlos
    Salazar, Filomena
    Relvas, Marta
    Braga, Ana Cristina
    Rios-Carrasco, Blanca
    Gil, Javier
    Rios-Santos, Jose Vicente
    Fernandez-Palacin, Ana
    Herrero-Climent, Mariano
    MATERIALS, 2022, 15 (04)
  • [6] Influence of Abutment Fabrication Method on 3D Fit at the Implant-Abutment Connection
    Ramalho, Ilana
    Witek, Lukasz
    Coelho, Paulo G.
    Bergamo, Edmara
    Pegoraro, Luiz Fernando
    Bonfante, Estevam A.
    INTERNATIONAL JOURNAL OF PROSTHODONTICS, 2020, 33 (06) : 641 - 647
  • [7] The effect of abutment material stiffness on the mechanical behavior of dental implant assemblies: A 3D finite element study
    Tonin, Bruna S. H.
    Fu, Jing
    He, Yiting
    Ye, Ning
    Chew, Hooi Pin
    Fok, Alex
    JOURNAL OF THE MECHANICAL BEHAVIOR OF BIOMEDICAL MATERIALS, 2023, 142
  • [8] Effects of Marginal Bone Loss Progression on Stress Distribution in Different Implant-Abutment Connections and Abutment Materials: A 3D Finite Element Analysis Study
    Lin, Ching-Ping
    Shyu, Yi-Ting
    Wu, Yu-Ling
    Tsai, Ming-Hsu
    Chen, Hung-Shyong
    Wu, Aaron Yu-Jen
    MATERIALS, 2022, 15 (17)
  • [9] Preload and friction in an implant–abutment–screw complex including a carbon-coated titanium alloy abutment screw: an in vitro study
    K. Sagheb
    C.-I. Görgen
    S. Döll
    I. Schmidtmann
    S. Wentaschek
    International Journal of Implant Dentistry, 9
  • [10] Stress Evaluation of Implant-Abutment Connections Under Different Loading Conditions: A 3D Finite Element Study
    Ferreira Koyama Takahashi, Jessica Mie
    Dayrell, Andreza Costa
    Xediek Consani, Rafael Leonardo
    de Arruda Nobilo, Mauro Antonio
    Pessanha Henriques, Guilherme Elias
    Mesquita, Marcelo Ferraz
    Journal of Oral Implantology, 2015, 41 (02) : 133 - 137