Effects of abutment screw preload in two implant connection systems: A 3D finite element study

被引:7
|
作者
Jung, Won-kyung [1 ,2 ]
Lee, Won-sup [3 ,4 ]
Kwon, Ho-Beom [1 ,2 ]
机构
[1] Seoul Natl Univ, Sch Dent, Dent Res Inst, 101 Daehak Ro, Seoul 110744, South Korea
[2] Seoul Natl Univ, Sch Dent, Dept Prosthodont, 101 Daehak Ro, Seoul 110744, South Korea
[3] Seoul Natl Univ, Grad Sch Dent, Dept Prosthodont, Seoul, South Korea
[4] Catholic Univ Korea, Dent Hosp, Dept Prosthodont, St Marys Hosp, Seoul, South Korea
来源
JOURNAL OF PROSTHETIC DENTISTRY | 2019年 / 122卷 / 05期
基金
新加坡国家研究基金会;
关键词
STRESS-DISTRIBUTION; LOADING CONDITIONS; BONE;
D O I
10.1016/j.prosdent.2019.04.025
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Statement of problem. Finite element analysis (FEA) has been used to evaluate the biomechanical behaviors of dental implants. However, in some FEA studies, the influence of the preload condition has been omitted to simplify the analysis. This might affect the results of biomechanical analysis significantly. The preload condition requires analysis. Purpose. The purpose of this FEA study was to evaluate and verify the effects of the presence of the preload condition on abutment screws under the occlusal load for external and internal hexagonal connection systems. Material and method. The finite element models consisting of bone blocks, 2 different implant systems (Osstem US and GS system; Osstem Implant Co), and crowns were created. With these components, a total of 6 models with different conditions were constructed for FEA: external hexagonal connection system only with preload (E0), external hexagonal connection system with no preload but occlusal load (EN), external hexagonal system with both preload and occlusal load (EP), internal hexagonal system only with preload (10), internal hexagonal system with no preload but occlusal load (IN), and internal hexagonal system with both preload and occlusal load (IP). An 113-degree oblique load (100 N) to the axis of the implant was applied on the occlusal surface of the crown for the models with occlusal load. A preload of 825 N was applied in the abutment screw of the models EO, EP, IO, and IP. The maximum von Mises stress, maximum principal stress, and maximum displacement of the components of the models were evaluated. Results. Both external and internal connection systems resulted in higher maximum von Mises stress and maximum principal stress values in the presence of preload in the abutment screw. The internal connection system showed higher displacement values than the external system with or without occlusal loading, and values tended to increase with the preload condition. Conclusion. The presence of a preload condition significantly affected the biomechanical behaviors of the components of 2 different connection systems. The preload condition should be included in FEA to achieve more realistic results.
引用
收藏
页码:474.e1 / 474.e8
页数:8
相关论文
共 50 条
  • [41] A SENSITIVITY STUDY BY FINITE ELEMENT ANALYSIS FOR THE ABUTMENT-IMPLANT-BONE SYSTEM
    Muraev, A. A.
    Tatoyan, A. D.
    Dolgalev, A. A.
    Vershinin, A. V.
    Yakovlev, M. Ya.
    Ivanov, S. Yu
    Konovalov, D. A.
    Petrovsky, K. A.
    Levin, V. A.
    MATHEMATICS AND MECHANICS OF COMPLEX SYSTEMS, 2022, 10 (01) : 1 - 20
  • [42] Melting in a Single Screw Extruder: Experiments and 3D Finite Element Simulations
    Altinkaynak, A.
    Gupta, M.
    Spalding, M. A.
    Crabtree, S. L.
    INTERNATIONAL POLYMER PROCESSING, 2011, 26 (02) : 182 - 196
  • [43] Peri-implant bone alterations under the influence of abutment screw preload stress. A preclinical vivo study
    Al-Omari, Farah A.
    Nagasawa, Masako
    Suliman, Mubarak
    Khraisat, Ameen
    Uoshima, Katsumi
    CLINICAL ORAL IMPLANTS RESEARCH, 2020, 31 (12) : 1232 - 1242
  • [44] Crestal and Subcrestal Placement of Morse Cone Implant-Abutment Connection Implants: An In Vitro Finite Element Analysis (FEA) Study
    Comuzzi, Luca
    Ceddia, Mario
    Di Pietro, Natalia
    Inchingolo, Francesco
    Inchingolo, Angelo Michele
    Romasco, Tea
    Tumedei, Margherita
    Specchiulli, Alessandro
    Piattelli, Adriano
    Trentadue, Bartolomeo
    BIOMEDICINES, 2023, 11 (11)
  • [45] Workflow Development of a 3D Printed Novel Implant Abutment
    Kalman, Les
    Hosein, Yara
    Chimel, Tom
    3D PRINTING AND ADDITIVE MANUFACTURING, 2019, 6 (05) : 235 - 237
  • [46] Effect of Implant Height Differences on Different Attachment Types and Peri-Implant Bone in Mandibular Two-Implant Overdentures: 3D Finite Element Study
    Ozan, Oguz
    Ramoglu, Serhat
    JOURNAL OF ORAL IMPLANTOLOGY, 2015, 41 (03) : E50 - E59
  • [47] Abutment stability analysis of arch dam based on 3D nonlinear finite element method
    Liu, Yaoru
    Yang, Qiang
    Zhu, Ling
    Yanshilixue Yu Gongcheng Xuebao/Chinese Journal of Rock Mechanics and Engineering, 2008, 27 (SUPPL.): : 3222 - 3228
  • [48] Finite Element Analysis of the Screw Arrangement Effects on the Connection Behaviour for Cold Formed Steel Truss Systems
    De'nan, Fatimah
    Choong, Kok Keong
    Loo, Jessica Si Jia
    Hashim, Nor Salwani
    PROCEEDINGS OF AICCE'19: TRANSFORMING THE NATION FOR A SUSTAINABLE TOMORROW, 2020, 53 : 229 - 247
  • [49] Effect of implant abutment connection designs, and implant diameters on screw loosening before and after cyclic loading: In-vitro study
    Sammour, Sara Reda
    El-Sheikh, Mohamed Maamoun
    El-Gendy, Attiah Aly
    DENTAL MATERIALS, 2019, 35 (11) : E265 - E271
  • [50] Effect of the prosthetic index on stress distribution in Morse taper connection implant system and peri-implant bone: a 3D finite element analysis
    Zhang, Wen-tao
    Cheng, Kang-jie
    Liu, Yun-feng
    Wang, Russell
    Chen, Yun-fang
    Ding, Yu-de
    Yang, Fan
    Wang, Lin-hong
    BMC ORAL HEALTH, 2022, 22 (01)