Effects of Screw Configuration on the Preload Force of Implant-Abutment Screws

被引:17
|
作者
Zipprich, Holger [1 ]
Rathe, Florian [2 ]
Pinz, Soeren [3 ]
Schlotmann, Luca [3 ]
Lauer, Hans-Christoph [3 ]
Ratka, Christoph [3 ]
机构
[1] Goethe Univ Frankfurt, Dept Prosthodont, Mat Sci Unit, Frankfurt, Germany
[2] DANUBE Private Univ, Dept Prosthodont, Krems An Der Donau, Austria
[3] Goethe Univ Frankfurt, Dept Prosthodont, Theodor Stern Kai 7,House 29, DE-60596 Frankfurt, Germany
关键词
abutment; abutment screw; abutment screw configuration; dental implant; preload force; thread pitch; FINITE-ELEMENT-ANALYSIS; BONE;
D O I
10.11607/jomi.5837
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Purpose: The aim of this study was to investigate the effects of tightening torque, screw head angle, and thread number on the preload force of abutment screws. Materials and Methods: The test specimens consisted of three self-manufactured components (ie, a thread sleeve serving as an implant analog, an abutment analog, and an abutment screw). The abutment screws were fabricated with metric M1.6 external threads. The thread number varied between one and seven threads. The screw head angles were produced in eight varying angles (30 to 180 degrees). A sensor unit simultaneously measured the preload force of the screw and the torsion moment inside the screw shank. The tightening of the screw with the torque wrench was performed in five steps (15 to 35 Ncm). The torque wrench was calibrated before each step. Results: Only the tightening torque and screw head angle affected the resulting preload force of the implant-abutment connection. The thread number had no effect. There was an approximately linear correlation between tightening torque and preload force. Conclusion: The tightening torque and screw head angle were the only study parameters that affected the resulting preload force of the abutment screw. The results obtained from this experiment are valid only for a single torque condition. Further investigations are needed that analyze other parameters that affect preload force. Once these parameters are known, it will add value for a strong, but detachable connection between the implant and abutment. Short implants and flat-to-flat connections especially will benefit significantly from this knowledge.
引用
收藏
页码:E25 / E32
页数:8
相关论文
共 50 条
  • [1] Increasing implant-abutment preload by thin-gold coating abutment screws
    Porter, SS
    Robb, TT
    JOURNAL OF DENTAL RESEARCH, 1998, 77 : 837 - 837
  • [2] Implant-abutment screw joint preload of 7 hex-top abutment systems
    Tan, KB
    Nicholls, JI
    INTERNATIONAL JOURNAL OF ORAL & MAXILLOFACIAL IMPLANTS, 2001, 16 (03) : 367 - 377
  • [3] Effects of Abutment Screw Coating on Implant Preload
    Park, Jae-Kyoung
    Choi, Jin-Uk
    Jeon, Young-Chan
    Choi, Kyung-Soo
    Jeong, Chang-Mo
    JOURNAL OF PROSTHODONTICS-IMPLANT ESTHETIC AND RECONSTRUCTIVE DENTISTRY, 2010, 19 (06): : 458 - 464
  • [4] Influence of different agents on the preload force of implant abutment screws
    Rathe, Florian
    Ratka, Christoph
    Kaesmacher, Christoph
    Winter, Anna
    Brandt, Silvia
    Zipprich, Holger
    JOURNAL OF PROSTHETIC DENTISTRY, 2021, 126 (04): : 581 - 585
  • [5] Influence of Anodizing Stages on the Preload Force of Implant-Abutment Screws and Their Benefits Regarding the Concept of Immediate Implant Placement-An In Vitro Study
    Rathe, Florian
    Weigl, Paul
    Wasiak, Jan
    Ratka, Christoph
    Zipprich, Holger
    MATERIALS, 2022, 15 (03)
  • [6] Influence of Implant Connection, Abutment Design and Screw Insertion Torque on Implant-Abutment Misfit
    Velez, Jorge
    Pelaez, Jesus
    Lopez-Suarez, Carlos
    Agustin-Panadero, Ruben
    Tobar, Celia
    Suarez, Maria J.
    JOURNAL OF CLINICAL MEDICINE, 2020, 9 (08) : 1 - 13
  • [7] The influence of implant-abutment connection on the screw loosening and microleakage
    Tsuruta, Katsuhiro
    Ayukawa, Yasunori
    Matsuzaki, Tatsuya
    Kihara, Masafumi
    Koyano, Kiyoshi
    INTERNATIONAL JOURNAL OF IMPLANT DENTISTRY, 2018, 4
  • [8] COMPARISON OF ABUTMENT SCREW PRELOAD IN DIFFERENT IMPLANT DESIGNS
    MILLER, RB
    MCGLUMPHY, EA
    KERBY, RE
    JOURNAL OF DENTAL RESEARCH, 1994, 73 : 202 - 202
  • [9] Effect of double conical abutment screw on implant preload
    Arnetzl, Gerwin Vincent
    Payer, Michael
    Falkensammer, Frank
    Arnetzl, Gerwin
    CLINICAL ORAL IMPLANTS RESEARCH, 2016, 27 (05) : 553 - 557
  • [10] Effects of Aging Torque Controllers on Screw Tightening Force and Bacterial Micro-Leakage on the Implant-Abutment Complex
    Jiries, Yousef
    Brosh, Tamar
    Matalon, Shlomo
    Perlis, Vladimir
    Ormianer, Zeev
    MATERIALS, 2022, 15 (02)