Effects of Screw Configuration on the Preload Force of Implant-Abutment Screws

被引:17
|
作者
Zipprich, Holger [1 ]
Rathe, Florian [2 ]
Pinz, Soeren [3 ]
Schlotmann, Luca [3 ]
Lauer, Hans-Christoph [3 ]
Ratka, Christoph [3 ]
机构
[1] Goethe Univ Frankfurt, Dept Prosthodont, Mat Sci Unit, Frankfurt, Germany
[2] DANUBE Private Univ, Dept Prosthodont, Krems An Der Donau, Austria
[3] Goethe Univ Frankfurt, Dept Prosthodont, Theodor Stern Kai 7,House 29, DE-60596 Frankfurt, Germany
关键词
abutment; abutment screw; abutment screw configuration; dental implant; preload force; thread pitch; FINITE-ELEMENT-ANALYSIS; BONE;
D O I
10.11607/jomi.5837
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Purpose: The aim of this study was to investigate the effects of tightening torque, screw head angle, and thread number on the preload force of abutment screws. Materials and Methods: The test specimens consisted of three self-manufactured components (ie, a thread sleeve serving as an implant analog, an abutment analog, and an abutment screw). The abutment screws were fabricated with metric M1.6 external threads. The thread number varied between one and seven threads. The screw head angles were produced in eight varying angles (30 to 180 degrees). A sensor unit simultaneously measured the preload force of the screw and the torsion moment inside the screw shank. The tightening of the screw with the torque wrench was performed in five steps (15 to 35 Ncm). The torque wrench was calibrated before each step. Results: Only the tightening torque and screw head angle affected the resulting preload force of the implant-abutment connection. The thread number had no effect. There was an approximately linear correlation between tightening torque and preload force. Conclusion: The tightening torque and screw head angle were the only study parameters that affected the resulting preload force of the abutment screw. The results obtained from this experiment are valid only for a single torque condition. Further investigations are needed that analyze other parameters that affect preload force. Once these parameters are known, it will add value for a strong, but detachable connection between the implant and abutment. Short implants and flat-to-flat connections especially will benefit significantly from this knowledge.
引用
收藏
页码:E25 / E32
页数:8
相关论文
共 50 条
  • [31] EXPERIMENTAL STUDY OF THE REMOVAL FORCE IN TAPERED IMPLANT-ABUTMENT INTERFACES: A PILOT STUDY
    Aguirrebeitia, Josu
    Mueftue, Sinan
    Abasolo, Mikel
    Vallejo, Javier
    JOURNAL OF PROSTHETIC DENTISTRY, 2014, 111 (04): : 293 - 300
  • [32] Effects of abutment screw preload in two implant connection systems: A 3D finite element study
    Jung, Won-kyung
    Lee, Won-sup
    Kwon, Ho-Beom
    JOURNAL OF PROSTHETIC DENTISTRY, 2019, 122 (05): : 474.e1 - 474.e8
  • [33] Preload and torque removal evaluation of three different abutment screws for single standing implant restorations
    Stuker, Rafael Augusto
    Teixeira, Eduardo Rolim
    Pinheiro Beck, Joao Carlos
    da Costa, Nilza Pereira
    JOURNAL OF APPLIED ORAL SCIENCE, 2008, 16 (01) : 55 - 58
  • [34] Fixture abutment screw joint preload of seven abutment systems
    Tan, KBC
    Nicholls, JJ
    Goh, JCH
    JOURNAL OF DENTAL RESEARCH, 2000, 79 (05) : 1322 - 1322
  • [35] Marginal fit and microgaps of implant-abutment interface with internal anti-rotation configuration
    Tsuge, Takuma
    Hagiwara, Yoshiyuki
    Matsumura, Hideo
    DENTAL MATERIALS JOURNAL, 2008, 27 (01) : 29 - 34
  • [36] Comparative effect of implant-abutment connections, abutment angulations, and screw lengths on preloaded abutment screw using three-dimensional finite element analysis: An in vitro study
    Kanneganti, Krishna Chaitanya
    Vinnakota, Dileep Nag
    Pottem, Srinivas Rao
    Pulagam, Mahesh
    JOURNAL OF INDIAN PROSTHODONTIC SOCIETY, 2018, 18 (02): : 161 - 167
  • [37] Effects of surface coating on the screw loosening of dental abutment screws
    Park, CI
    Choe, HC
    Chung, CH
    METALS AND MATERIALS INTERNATIONAL, 2004, 10 (06) : 549 - 553
  • [38] Can gold coating on abutment screws increase preload?
    Liu, YH
    Lin, LD
    Wang, JS
    JOURNAL OF DENTAL RESEARCH, 2000, 79 (05) : 1329 - 1329
  • [39] Effect of Screw Channel Angulation on Reverse Torque Values of Dental Implant Abutment Screws
    Hu, Eric
    Petrich, Anton
    Imamura, Glen
    Hamlin, Christopher
    JOURNAL OF PROSTHODONTICS-IMPLANT ESTHETIC AND RECONSTRUCTIVE DENTISTRY, 2019, 28 (09): : 969 - 972
  • [40] Impact of Implantoplasty on Strength of the Implant-Abutment Complex
    Chan, Hsun-Liang
    Oh, Won-Suck
    Ong, Hwei Sze
    Fu, Jia-Hui
    Steigmann, Marius
    Sierraalta, Marianella
    Wang, Hom-Lay
    INTERNATIONAL JOURNAL OF ORAL & MAXILLOFACIAL IMPLANTS, 2013, 28 (06) : 1530 - 1535