Effects of Screw Configuration on the Preload Force of Implant-Abutment Screws

被引:17
|
作者
Zipprich, Holger [1 ]
Rathe, Florian [2 ]
Pinz, Soeren [3 ]
Schlotmann, Luca [3 ]
Lauer, Hans-Christoph [3 ]
Ratka, Christoph [3 ]
机构
[1] Goethe Univ Frankfurt, Dept Prosthodont, Mat Sci Unit, Frankfurt, Germany
[2] DANUBE Private Univ, Dept Prosthodont, Krems An Der Donau, Austria
[3] Goethe Univ Frankfurt, Dept Prosthodont, Theodor Stern Kai 7,House 29, DE-60596 Frankfurt, Germany
关键词
abutment; abutment screw; abutment screw configuration; dental implant; preload force; thread pitch; FINITE-ELEMENT-ANALYSIS; BONE;
D O I
10.11607/jomi.5837
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Purpose: The aim of this study was to investigate the effects of tightening torque, screw head angle, and thread number on the preload force of abutment screws. Materials and Methods: The test specimens consisted of three self-manufactured components (ie, a thread sleeve serving as an implant analog, an abutment analog, and an abutment screw). The abutment screws were fabricated with metric M1.6 external threads. The thread number varied between one and seven threads. The screw head angles were produced in eight varying angles (30 to 180 degrees). A sensor unit simultaneously measured the preload force of the screw and the torsion moment inside the screw shank. The tightening of the screw with the torque wrench was performed in five steps (15 to 35 Ncm). The torque wrench was calibrated before each step. Results: Only the tightening torque and screw head angle affected the resulting preload force of the implant-abutment connection. The thread number had no effect. There was an approximately linear correlation between tightening torque and preload force. Conclusion: The tightening torque and screw head angle were the only study parameters that affected the resulting preload force of the abutment screw. The results obtained from this experiment are valid only for a single torque condition. Further investigations are needed that analyze other parameters that affect preload force. Once these parameters are known, it will add value for a strong, but detachable connection between the implant and abutment. Short implants and flat-to-flat connections especially will benefit significantly from this knowledge.
引用
收藏
页码:E25 / E32
页数:8
相关论文
共 50 条
  • [21] Influence of repeated screw tightening on bacterial leakage along the implant-abutment interface
    do Nascimento, Cassio
    Pedrazzi, Vinicius
    Miani, Paola Kirsten
    Moreira, Larissa Daher
    de Albuquerque Junior, Rubens Ferreira
    CLINICAL ORAL IMPLANTS RESEARCH, 2009, 20 (12) : 1394 - 1397
  • [22] Preload, Coefficient of Friction, and Thread Friction in an Implant-Abutment-Screw Complex
    Wentaschek, Stefan
    Tomalla, Sven
    Schmidtmann, Irene
    Lehmann, Karl Martin
    INTERNATIONAL JOURNAL OF PROSTHODONTICS, 2017, 30 (06) : 542 - 544
  • [23] Influence of Abutment Type and Esthetic Veneering on Preload Maintenance of Abutment Screw of Implant-Supported Crowns
    Delben, Juliana Aparecida
    Ricardo Barao, Valentim Adelino
    Dos Santos, Paulo Henrique
    Assuncao, Wirley Goncalves
    JOURNAL OF PROSTHODONTICS-IMPLANT ESTHETIC AND RECONSTRUCTIVE DENTISTRY, 2014, 23 (02): : 134 - 139
  • [24] Preload and friction in an implant–abutment–screw complex including a carbon-coated titanium alloy abutment screw: an in vitro study
    K. Sagheb
    C.-I. Görgen
    S. Döll
    I. Schmidtmann
    S. Wentaschek
    International Journal of Implant Dentistry, 9
  • [25] Critical bending moment of implant-abutment screw joint interfaces: Effect of torque levels and implant diameter
    Tan, BF
    Tan, KB
    Nicholls, JI
    INTERNATIONAL JOURNAL OF ORAL & MAXILLOFACIAL IMPLANTS, 2004, 19 (05) : 648 - 658
  • [26] In Vitro Evaluation of Manual Torque Values Applied to Implant-Abutment Complex by Different Clinicians and Abutment Screw Loosening
    Kose, Onur Dincer
    Karatasli, Burcin
    Demircan, Sabit
    Kose, Taha Emre
    Cene, Erhan
    Aya, Serhan Aydjn
    Erdem, Mehmet Ali
    Cankaya, Abdulkadir Burak
    BIOMED RESEARCH INTERNATIONAL, 2017, 2017
  • [27] Implant-Abutment Connections: A Structured Review
    Hariharan A.S.
    Sivaswamy V.
    Subhashini R.
    Journal of Long-Term Effects of Medical Implants, 2022, 33 (01) : 47 - 56
  • [28] Preload and friction in an implant-abutment-screw complex including a carbon-coated titanium alloy abutment screw: an in vitro study
    Sagheb, K.
    Goergen, C. -I.
    Doell, S.
    Schmidtmann, I.
    Wentaschek, S.
    INTERNATIONAL JOURNAL OF IMPLANT DENTISTRY, 2023, 9 (01)
  • [29] Evaluation of UCLA Implant-Abutment Sealing
    Ramos, Marcelo B.
    Pegoraro, Luiz F.
    Takamori, Esther
    Coelho, Paulo G.
    Silva, Thelma L.
    Bonfante, Estevam A.
    INTERNATIONAL JOURNAL OF ORAL & MAXILLOFACIAL IMPLANTS, 2014, 29 (01) : 113 - 120
  • [30] Mechanical resistance of screwless morse taper and screw-retained implant-abutment connections
    Ugurel, Cihan Sadi
    Steiner, Martin
    Isik-Ozkol, Gul
    Kutay, Omer
    Kern, Matthias
    CLINICAL ORAL IMPLANTS RESEARCH, 2015, 26 (02) : 137 - 142