Speech perception, localization, and lateralization with bilateral cochlear implants

被引:355
|
作者
van Hoesel, RJM [1 ]
Tyler, RS
机构
[1] CRC Cochlear Implant & Hearing Aid Innovat, Melbourne, Vic, Australia
[2] Univ Iowa, Dept Otolaryngol Head & Neck Surg, Iowa City, IA 52242 USA
[3] Univ Iowa, Dept Speech Pathol & Audiol, Iowa City, IA 52242 USA
来源
关键词
D O I
10.1121/1.1539520
中图分类号
O42 [声学];
学科分类号
070206 ; 082403 ;
摘要
Five bilateral cochlear implant users were tested for their localization abilities and speech understanding in noise, for both monaural and binaural listening conditions. They also participated in lateralization tasks to assess the impact of variations in interaural time delays (ITDs) and interaural level differences (ILDs) for, electrical pulse trains under direct computer control. The localization task used pink noise bursts presented from an, eight-loudspeaker array spanning an arc of approximately 108degrees in front of the listeners at ear level (0-degree elevation). Subjects showed large benefits from bilateral device use compared to either side alone. Typical root-mean-square (rms) averaged errors across all eight loudspeakers in the array were about 10degrees for bilateral device use and ranged from 20degrees to 60degrees using either ear alone. Speech reception thresholds (SRTs) were measured for sentences presented from directly in front of the listeners (0degrees) in spectrally matching speech-weighted noise at either 0degrees, +90degrees or -90degrees for four subjects out of five tested who could perform the task. For noise to either side, bilateral device use showed a substantial benefit over unilateral device use when noise was ipsilateral to the unilateral device. This was primarily because of monaural head-shadow effects, which resulted in robust SRT improvements (P < 0.001) of about 4 to 5 dB when ipsilateral and contralateral noise positions were compared. The additional benefit of using both ears compared to the shadowed ear (i.e., binaural unmasking) was only 1 or 2 dB and less robust (P = 0.04). Results from the lateralization studies showed consistently good sensitivity to ILDs; better than the smallest level adjustment available in the implants (0.17 dB) for some subjects. Sensitivity to ITDs was moderate on the other hand, typically of the order of 100 mu s. ITD sensitivity deteriorated rapidly when stimulation rates for unmodulated pulse-trains increased above a few hundred Hz but at 800 pps showed sensitivity comparable to 50-pps pulse-trains when a 50-Hz modulation was applied. In our opinion, these results clearly demonstrate important benefits are available from bilateral implantation, both for localizing sounds (in quiet) and for listening in noise when signal and noise sources are spatially separated. The data do indicate, however, that effects of interaural timing cues are weaker than those from interaural level cues and according to our psychophysical findings rely on the availability of low-rate information below a few hundred Hz. (C) 2003 Acoustical Society of America.
引用
收藏
页码:1617 / 1630
页数:14
相关论文
共 50 条
  • [41] The effect of increased channel interaction on speech perception with cochlear implants
    Goehring, Tobias
    Archer-Boyd, Alan W.
    Arenberg, Julie G.
    Carlyon, Robert P.
    SCIENTIFIC REPORTS, 2021, 11 (01)
  • [42] Frequency-to-electrode allocation and speech perception with cochlear implants
    McKay, CM
    Henshall, KR
    JOURNAL OF THE ACOUSTICAL SOCIETY OF AMERICA, 2002, 111 (02): : 1036 - 1044
  • [43] Speech perception by prelingually deaf children using cochlear implants
    Tyler, RS
    FryaufBertschy, H
    Kelsay, DMR
    Gantz, BJ
    Woodworth, GP
    Parkinson, A
    OTOLARYNGOLOGY-HEAD AND NECK SURGERY, 1997, 117 (03) : 180 - 187
  • [44] Variation in speech perception scores among children with cochlear implants
    Sarant, JZ
    Blamey, PJ
    Dowell, RC
    Clark, GM
    Gibson, WPR
    EAR AND HEARING, 2001, 22 (01): : 18 - 28
  • [45] Speech perception performance in prelingually deaf children with cochlear implants
    Gstoettner, WK
    Hamzavi, J
    Egelierler, B
    Baumgartner, WD
    ACTA OTO-LARYNGOLOGICA, 2000, 120 (02) : 209 - 213
  • [46] Frequency-to-electrode allocation and speech perception with cochlear implants
    McKay, C.M. (colette@unimelb.edu.au), 1600, Acoustical Society of America (111):
  • [47] Speech perception results in children with cochlear implants: Contributing factors
    Hodges, AV
    Ash, MD
    Balkany, TJ
    Schloffman, JJ
    Butts, SL
    OTOLARYNGOLOGY-HEAD AND NECK SURGERY, 1999, 121 (01) : 31 - 34
  • [48] Semantic influences on the perception of degraded speech by individuals with cochlear implants
    Patro, Chhayakanta
    Mendel, Lisa Lucks
    JOURNAL OF THE ACOUSTICAL SOCIETY OF AMERICA, 2020, 147 (03): : 1778 - 1789
  • [49] Cochlear implants in young children: The relationship between speech perception and speech intelligibility
    O'Donoghue, GM
    Nikolopoulos, TP
    Archbold, SM
    Tait, M
    EAR AND HEARING, 1999, 20 (05): : 419 - 425
  • [50] Speech perception of Japanese language in patients using cochlear implants
    Kawano, M
    Naito, Y
    Takahashi, H
    Shiomi, Y
    Ito, J
    COCHLEAR IMPLANT AND RELATED SCIENCES UPDATE, 1997, 52 : 240 - 243