Speech perception, localization, and lateralization with bilateral cochlear implants

被引:355
|
作者
van Hoesel, RJM [1 ]
Tyler, RS
机构
[1] CRC Cochlear Implant & Hearing Aid Innovat, Melbourne, Vic, Australia
[2] Univ Iowa, Dept Otolaryngol Head & Neck Surg, Iowa City, IA 52242 USA
[3] Univ Iowa, Dept Speech Pathol & Audiol, Iowa City, IA 52242 USA
来源
关键词
D O I
10.1121/1.1539520
中图分类号
O42 [声学];
学科分类号
070206 ; 082403 ;
摘要
Five bilateral cochlear implant users were tested for their localization abilities and speech understanding in noise, for both monaural and binaural listening conditions. They also participated in lateralization tasks to assess the impact of variations in interaural time delays (ITDs) and interaural level differences (ILDs) for, electrical pulse trains under direct computer control. The localization task used pink noise bursts presented from an, eight-loudspeaker array spanning an arc of approximately 108degrees in front of the listeners at ear level (0-degree elevation). Subjects showed large benefits from bilateral device use compared to either side alone. Typical root-mean-square (rms) averaged errors across all eight loudspeakers in the array were about 10degrees for bilateral device use and ranged from 20degrees to 60degrees using either ear alone. Speech reception thresholds (SRTs) were measured for sentences presented from directly in front of the listeners (0degrees) in spectrally matching speech-weighted noise at either 0degrees, +90degrees or -90degrees for four subjects out of five tested who could perform the task. For noise to either side, bilateral device use showed a substantial benefit over unilateral device use when noise was ipsilateral to the unilateral device. This was primarily because of monaural head-shadow effects, which resulted in robust SRT improvements (P < 0.001) of about 4 to 5 dB when ipsilateral and contralateral noise positions were compared. The additional benefit of using both ears compared to the shadowed ear (i.e., binaural unmasking) was only 1 or 2 dB and less robust (P = 0.04). Results from the lateralization studies showed consistently good sensitivity to ILDs; better than the smallest level adjustment available in the implants (0.17 dB) for some subjects. Sensitivity to ITDs was moderate on the other hand, typically of the order of 100 mu s. ITD sensitivity deteriorated rapidly when stimulation rates for unmodulated pulse-trains increased above a few hundred Hz but at 800 pps showed sensitivity comparable to 50-pps pulse-trains when a 50-Hz modulation was applied. In our opinion, these results clearly demonstrate important benefits are available from bilateral implantation, both for localizing sounds (in quiet) and for listening in noise when signal and noise sources are spatially separated. The data do indicate, however, that effects of interaural timing cues are weaker than those from interaural level cues and according to our psychophysical findings rely on the availability of low-rate information below a few hundred Hz. (C) 2003 Acoustical Society of America.
引用
收藏
页码:1617 / 1630
页数:14
相关论文
共 50 条
  • [21] Frequency and electrode contributions to localization in bilateral cochlear implants
    Dunn, CC
    Tyler, RS
    Witt, SA
    Gantz, B
    Rubinstein, J
    COCHLEAR IMPLANTS, 2004, 1273 : 443 - 446
  • [22] Influence of masks on speech perception in people with cochlear implants
    Teira, Celia
    Gomez, Irene Pomares
    REVISTA DE INVESTIGACION EN LOGOPEDIA, 2022, 12 (02):
  • [23] Perception of Synthetic Speech in Adult Users of Cochlear Implants
    Nagao, Kyoko
    Paullin, Mark
    Polikoff, James B.
    Lilley, Jason
    Bunnell, H. Timothy
    13TH ANNUAL CONFERENCE OF THE INTERNATIONAL SPEECH COMMUNICATION ASSOCIATION 2012 (INTERSPEECH 2012), VOLS 1-3, 2012, : 1454 - 1457
  • [24] Perception of Spectrally Shifted Speech: Implications for Cochlear Implants
    Nambi, Pitchai Muthu Arivudai
    Manoharan, Subramaniam
    Bhat, Jayashree Sunil
    Sangamanatha, Ankmnal Veeranna
    JOURNAL OF INTERNATIONAL ADVANCED OTOLOGY, 2011, 7 (03): : 379 - 384
  • [25] Development of speech perception and production in children with cochlear implants
    Kishon-Rabin, L
    Taitelbaum, R
    Muchnik, C
    Gehtler, I
    Kronenberg, J
    Hildesheimer, M
    ANNALS OF OTOLOGY RHINOLOGY AND LARYNGOLOGY, 2002, 111 (05): : 85 - 90
  • [26] Improving Speech Perception in Noise for Children with Cochlear Implants
    Gifford, Rene H.
    Olund, Amy P.
    DeJong, Melissa
    JOURNAL OF THE AMERICAN ACADEMY OF AUDIOLOGY, 2011, 22 (09) : 623 - 632
  • [27] Development of a test of speech perception for children with cochlear implants
    Kendall, MJ
    Summerfield, AQ
    BRITISH JOURNAL OF AUDIOLOGY, 1997, 31 (02): : 108 - 108
  • [28] Speech perception and speech production skills of children with multichannel cochlear implants
    Miyamoto, RT
    Kirk, KI
    Robbins, AM
    Todd, S
    Riley, A
    ACTA OTO-LARYNGOLOGICA, 1996, 116 (02) : 240 - 243
  • [29] Advantages from bilateral hearing in speech perception in noise with simulated cochlear implants and residual acoustic hearing
    Schoof, Tim
    Green, Tim
    Faulkner, Andrew
    Rosen, Stuart
    JOURNAL OF THE ACOUSTICAL SOCIETY OF AMERICA, 2013, 133 (02): : 1017 - 1030
  • [30] Speech Perception With Combined Electric-Acoustic Stimulation and Bilateral Cochlear Implants in a Multisource Noise Field
    Rader, Tobias
    Fastl, Hugo
    Baumann, Uwe
    EAR AND HEARING, 2013, 34 (03): : 324 - 332