Assessment of the Quality of Breast MR Imaging Using the Modified Dixon Method and Frequency-selective Fat Suppression: A Phantom Study

被引:5
|
作者
Takatsu, Yasuo [1 ,2 ]
Kyotani, Katsusuke [3 ]
Ueyama, Tsuyoshi [4 ]
Miyati, Tosiaki [2 ]
Yamamura, Kenichirou [2 ,5 ]
Andou, Atsushi [6 ]
机构
[1] Osaka Red Cross Hosp, Dept Radiol, Tennouji Ku, 5-30 Fudegasaki, Osaka, Osaka 5438555, Japan
[2] Kanazawa Univ, Grad Sch Med Sci, Div Hlth Sci, Kanazawa, Ishikawa, Japan
[3] Kobe Univ Hosp, Div Radiol, Kobe, Hyogo, Japan
[4] Univ Tokyo Hosp, Dept Radiol, Tokyo, Japan
[5] Osaka Med Coll Hosp, Dept Radiol, Osaka, Japan
[6] Takarazuka City Hosp, Dept Radiol, Takarazuka, Hyogo, Japan
关键词
breast; Dixon; e-Thrive; fat suppression; magnetic resonance imaging; TESLA;
D O I
10.2463/mrms.tn.2017-0144
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
To obtain objective and concrete data by physically assessing the quality of breast magnetic resonance images based on the fat-suppression effect by the modified Dixon method (mDixon) and frequency-selective fat suppression (e-Thrive) using an original lipid-content breast phantom that could easily reveal the influence of non-uniform fat suppression in breast magnetic resonance imaging. The fat-suppression uniformity was approximately seven times superior when using mDixon compared with when using e-Thrive. mDixon appears to have a significant advantage.
引用
收藏
页码:350 / 355
页数:6
相关论文
共 34 条
  • [21] Simplified Method for FROC Observer Study to Evaluate the Diagnostic Accuracy of a Digital Breast Imaging System by Using a CDMAM Phantom
    Tanaka, Rie
    Akita, Fujiyo
    Fukuoka, Daisuke
    Bamba, Yusuke
    Shiraishi, Junji
    BREAST IMAGING, IWDM 2016, 2016, 9699 : 83 - 88
  • [22] Modeling of radio-frequency induced currents on lead wires during MR imaging using a modified transmission line method
    Acikel, Volkan
    Atalar, Ergin
    MEDICAL PHYSICS, 2011, 38 (12) : 6623 - 6632
  • [24] Quality control study of image registration in 40 breast cancer MR imaging patients using Confirma CADstream software
    Middleton, MS
    Comstock, CE
    McNamara, MP
    AMERICAN JOURNAL OF ROENTGENOLOGY, 2004, 182 (04) : 11 - 12
  • [25] Effects of Imaging Parameters on the Quality of Contrast-Enhanced MR Angiography of Cerebral Aneurysms Treated Using Stent-Assisted Coiling: A Phantom Study
    Ikushima, Yoichiro
    Hashido, Takashi
    Watanabe, Yoshiyuki
    Doi, Tsukasa
    MAGNETIC RESONANCE IN MEDICAL SCIENCES, 2017, 16 (02) : 146 - 151
  • [26] Amide proton transfer-weighted imaging with a short acquisition time based on a self B0 correction using the turbo spin echo-Dixon method: A phantom study
    Tokunaga, Chiaki
    Wada, Tatsuhiro
    Togao, Osamu
    Kobayashi, Kouji
    Kato, Toyoyuki
    MAGNETIC RESONANCE IMAGING, 2024, 110 : 69 - 77
  • [27] Water quality assessment using comprehensive water quality index and modified Nemerow index method: A case study of Jinghui Canal, North China
    Zhang, Yuting
    Hou, Kai
    Qian, Hui
    FOURTH INTERNATIONAL CONFERENCE ON ENERGY ENGINEERING AND ENVIRONMENTAL PROTECTION, 2020, 467
  • [28] Subtractionless compressed-sensing-accelerated whole-body MR angiography using two-point Dixon fat suppression with single-pass half-reduced contrast dose: feasibility study and initial experience
    Fu, Qing
    Lei, Zi-qiao
    Li, Jing-yang
    Wu, Jia-wei
    Liu, Xiao-ming
    Fan, Wen-liang
    Sun, Peng
    Wang, Jia-zheng
    Liu, Ding-xi
    Yang, Fan
    Zheng, Chuan-sheng
    Kong, Xiang-chuang
    JOURNAL OF CARDIOVASCULAR MAGNETIC RESONANCE, 2023, 25 (01)
  • [29] Subtractionless compressed-sensing-accelerated whole-body MR angiography using two-point Dixon fat suppression with single-pass half-reduced contrast dose: feasibility study and initial experience
    Qing Fu
    Zi-qiao Lei
    Jing-yang Li
    Jia-wei Wu
    Xiao-ming Liu
    Wen-liang Fan
    Peng Sun
    Jia-zheng Wang
    Ding-xi Liu
    Fan Yang
    Chuan-sheng Zheng
    Xiang-chuang Kong
    Journal of Cardiovascular Magnetic Resonance, 25
  • [30] B1 and T1 Insensitive Water and Lipid Suppression Using Optimized Multiple Frequency-Selective Preparation Pulses for Whole-Brain 1H Spectroscopic Imaging at 3T
    Gu, Meng
    Spielman, Daniel M.
    MAGNETIC RESONANCE IN MEDICINE, 2009, 61 (02) : 462 - 466