Nanoporous TiO2 thin film based conductometric H2 sensor

被引:48
|
作者
Sadek, A. Z. [1 ]
Partridge, J. G. [2 ]
McCulloch, D. G. [2 ]
Li, Y. X. [3 ]
Yu, X. F. [3 ]
Wlodarski, W. [1 ]
Kalantar-zadeh, K. [1 ]
机构
[1] RMIT Univ, Sch Elect & Comp Engn, Melbourne, Vic 3001, Australia
[2] RMIT Univ, Sch Appl Sci, Melbourne, Vic 3001, Australia
[3] Chinese Acad Sci, Shanghai Inst Ceram, Shanghai 200050, Peoples R China
关键词
Nanoporous TiO2; Anodization; FCVA; H-2; sensor; NANOTUBE-ARRAYS; SOLAR-CELLS; GAS SENSOR; TITANIA; HYDROGEN; FABRICATION; ANODIZATION; GROWTH; LENGTH; LAYERS;
D O I
10.1016/j.tsf.2009.02.151
中图分类号
T [工业技术];
学科分类号
08 ;
摘要
Nanoporous titanium dioxide (TiO2) based conductometric sensors have been fabricated and their sensitivity to hydrogen (H-2) gas has been investigated. A filtered cathodic vacuum arc (FCVA) system was used to deposit ultra-smooth Ti thin films on a transducer having patterned inter-digital gold electrodes (IDTs). Nanoporous TiO2 films were obtained by anodization of the titanium (Ti) thin films using a neutral 0.5% (wt) NH4F in ethylene glycol solution at 5 V for 1 h. After anodization, the films were annealed at 600 degrees C for 8 h to convert the remaining Ti into TiO2. The scanning electron microscopy (SEM) images revealed that the average diameters of the nanopores are in the range of 20 to 25 nm. The sensor was exposed to different concentrations of H-2 in synthetic air at operating temperatures between 100 degrees C and 300 degrees C. The sensor responded with a highest sensitivity of 1.24 to 1% of H-2 gas at 225 degrees C. (C) 2009 Elsevier B.V. All rights reserved.
引用
收藏
页码:1294 / 1298
页数:5
相关论文
共 50 条
  • [21] Template-free self-assembly of a nanoporous TiO2 thin film
    Gao, Yanfeng
    Nagai, Masayuki
    Seo, Won-Seon
    Koumoto, Kunihito
    JOURNAL OF THE AMERICAN CERAMIC SOCIETY, 2007, 90 (03) : 831 - 837
  • [22] MEMS-Based Gas Sensor Using PdO-Decorated TiO2 Thin Film for Highly Sensitive and Selective H2 Detection with Low Power Consumption
    Seungmin Kwak
    Young-Seok Shim
    Yong Kyoung Yoo
    Jin-Hyung Lee
    Inho Kim
    Jinseok Kim
    Kyu Hyoung Lee
    Jeong Hoon Lee
    Electronic Materials Letters, 2018, 14 : 305 - 313
  • [23] MEMS-Based Gas Sensor Using PdO-Decorated TiO2 Thin Film for Highly Sensitive and Selective H2 Detection with Low Power Consumption
    Kwak, Seungmin
    Shim, Young-Seok
    Yoo, Yong Kyoung
    Lee, Jin-Hyung
    Kim, Inho
    Kim, Jinseok
    Lee, Kyu Hyoung
    Lee, Jeong Hoon
    ELECTRONIC MATERIALS LETTERS, 2018, 14 (03) : 305 - 313
  • [24] Comparison on TiO2 thin film deposition method for fluidic based glucose memristor sensor
    Hadis, Nor Shahanim Mohamad
    Manaf, Asrulnizam Abd
    Herman, Sukreen Hana
    2015 IEEE INTERNATIONAL CIRCUITS AND SYSTEMS SYMPOSIUM (ICSYS), 2015, : 36 - 39
  • [25] Sol-gel TIO2 thin film-based sensor for lambda measurement
    Presicce, DS
    Ficarella, A
    Laforgia, D
    Francioso, L
    Rella, R
    Siciliano, P
    SENSORS AND MICROSYSTEMS, PROCEEDINGS, 2004, : 200 - 205
  • [26] TiO2 thin film capacitive humidity sensor based on sol-gel technique
    Pandey, M. (manju.pandey22@yahoo.com), 1600, International Frequency Sensor Association, 46 Thorny Vineway, Toronto, ON M2J 4J2, Canada (142):
  • [27] A Micro Oxygen Sensor Based on a Nano Sol-Gel TiO2 Thin Film
    Wang, Hairong
    Chen, Lei
    Wang, Jiaxin
    Sun, Quantao
    Zhao, Yulong
    SENSORS, 2014, 14 (09): : 16423 - 16433
  • [28] An Ultrasensitive Room-Temperature H2 Sensor Based on a TiO2 Rutile-Anatase Homojunction
    Wu, Xuefeng
    Zhang, Ya
    Zhang, Menghan
    Liang, Jianhu
    Bao, Yuwen
    Xia, Xiaohong
    Homewood, Kevin
    Lourenco, Manon
    Gao, Yun
    SENSORS, 2024, 24 (03)
  • [29] Tin dioxide nanodimensional film based H2 sensor
    Dmitriev, Serghei
    Nanostructured Materials and Hybrid Composites for Gas Sensors and Biomedical Applications, 2006, 915 : 203 - 208
  • [30] Gas sensor using anodic TiO2 thin film for monitoring hydrogen
    Moon, J.
    Kemell, M.
    Kukkola, J.
    Punkkinen, R.
    Hedman, H-P.
    Suominen, A.
    Makila, E.
    Tenho, M.
    Tuominen, A.
    Kim, H.
    26TH EUROPEAN CONFERENCE ON SOLID-STATE TRANSDUCERS, EUROSENSOR 2012, 2012, 47 : 791 - 794