Indoor/outdoor air pollution relationships in ten commercial buildings: PM2.5 and NO2

被引:103
|
作者
Challoner, Avril [1 ]
Gill, Laurence [1 ]
机构
[1] Univ Dublin Trinity Coll, Dept Civil Struct & Environm Engn, Dublin 2, Ireland
关键词
NO2; PM2.5; Indoor air quality; Urban environment; Buildings; Ventilation; AIRBORNE PARTICULATE MATTER; NITROGEN-DIOXIDE; PERSONAL EXPOSURES; ORGANIC-COMPOUNDS; OFFICE WORKERS; OUTDOOR AIR; INDOOR; URBAN; QUALITY; POLLUTANTS;
D O I
10.1016/j.buildenv.2014.05.032
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
PM2.5 and NO2 concentrations were measured simultaneously indoors and outdoors for ten different city centre buildings (shops and offices) in Dublin, Ireland. Outdoor concentrations were measured in two locations either at ground level outside the building or at the air intake of the building's ventilation system. The ratio of indoor to outdoor (I/O) PM2.5 concentrations were all found to be close to or above 1, indicating that either the fabric and/or operational environment of the buildings, whether naturally or mechanically ventilated, was not performing any significant function to reduce particulate concentrations from outdoors or that indoor sources were present. Indoor PM2.5 concentrations during working hours were generally below 25 i.tg I11-3 PM2.5, with naturally ventilated shops showing the highest concentrations. Lower indoor NO2 concentrations were measured during working hours in naturally ventilated buildings compared to the mechanically ventilated buildings, although most buildings showed strong diurnal relationships between outdoor NO2 concentrations and indoor air quality. Indeed, street level concentrations of NO2 seemed to have a stronger influence on the indoor air quality of the mechanically ventilated buildings, than with the corresponding air quality measured at their roof level ventilation intakes. The buildings with the greatest reduction for NO2 were older naturally ventilated offices. I/O ratios of both pollutants, but particularly NO2, increased significantly overnight as outdoor concentrations reduced to a much greater extent than indoors. This would indicate a benefit in promoting increased air exchange between the outdoors and indoors during night time periods in order to flush out air pollutants. (C) 2014 Elsevier Ltd. All rights reserved.
引用
收藏
页码:159 / 173
页数:15
相关论文
共 50 条
  • [41] Numerical Simulation of PM2.5 Distribution in Indoor Air
    Ma, Yuting
    Jiang, Yiqiang
    Li, Lan
    9TH INTERNATIONAL SYMPOSIUM ON HEATING, VENTILATION AND AIR CONDITIONING (ISHVAC) JOINT WITH THE 3RD INTERNATIONAL CONFERENCE ON BUILDING ENERGY AND ENVIRONMENT (COBEE), 2015, 121 : 1939 - 1947
  • [42] Comparison of indoor and outdoor oxidative potential of PM2.5: pollution levels, temporal patterns, and key constituents
    Yang, Fan
    Liu, Cong
    Qian, Hua
    ENVIRONMENT INTERNATIONAL, 2021, 155
  • [43] The effect of PM2.5 air pollution on the frosting process of outdoor finned-tube evaporator
    Shen, Chao
    Ma, Junfei
    Pu, Jihong
    Hu, Yunhao
    Yao, Yang
    Deng, Shiming
    ENERGY AND BUILDINGS, 2020, 213
  • [44] Investigation of outdoor air pollutant, PM2.5 affecting the indoor air quality in a high-rise building
    Fu, Nuodi
    Kim, Moon Keun
    Chen, Bing
    Sharples, Stephen
    INDOOR AND BUILT ENVIRONMENT, 2022, 31 (04) : 895 - 912
  • [45] Determinants of indoor air concentrations of PM2.5, black smoke and NO2 in six European cities (EXPOLIS study)
    Lai, HK
    Bayer-Oglesby, L
    Colvile, R
    Götschi, T
    Jantunen, MJ
    Künzli, N
    Kulinskaya, E
    Schweizer, C
    Nieuwenhuijsen, MJ
    ATMOSPHERIC ENVIRONMENT, 2006, 40 (07) : 1299 - 1313
  • [46] RELATIONSHIPS BETWEEN OUTDOOR AND INDOOR AIR-POLLUTION
    ANDERSEN, I
    ATMOSPHERIC ENVIRONMENT, 1972, 6 (04) : 275 - &
  • [47] RELATIONSHIPS BETWEEN OUTDOOR AND INDOOR AIR-POLLUTION
    SPEDDING, DJ
    ATMOSPHERIC ENVIRONMENT, 1973, 7 (03) : 376 - 376
  • [48] RELATIONSHIPS BETWEEN OUTDOOR AND INDOOR AIR-POLLUTION
    DEGRAAF, H
    BIERSTEK.K
    ATMOSPHERIC ENVIRONMENT, 1972, 6 (09) : 698 - &
  • [49] Indoor PM2.5 from occupied residences in Sweden caused higher inflammation in mice compared to outdoor PM2.5
    Wierzbicka, Aneta
    Omelekhina, Yuliya
    Saber, Anne Thoustrup
    Bloom, Erica
    Gren, Louise
    Poulsen, Sarah Sos
    Strandberg, Bo
    Pagels, Joakim
    Jacobsen, Nicklas Raun
    INDOOR AIR, 2022, 32 (12)
  • [50] Vertical distribution of PAHs in the indoor and outdoor PM2.5 in Guangzhou, China
    Li, CL
    Fu, JM
    Sheng, GY
    Bi, XH
    Hao, YM
    Wang, XM
    Mai, BX
    BUILDING AND ENVIRONMENT, 2005, 40 (03) : 329 - 341