Indoor/outdoor air pollution relationships in ten commercial buildings: PM2.5 and NO2

被引:103
|
作者
Challoner, Avril [1 ]
Gill, Laurence [1 ]
机构
[1] Univ Dublin Trinity Coll, Dept Civil Struct & Environm Engn, Dublin 2, Ireland
关键词
NO2; PM2.5; Indoor air quality; Urban environment; Buildings; Ventilation; AIRBORNE PARTICULATE MATTER; NITROGEN-DIOXIDE; PERSONAL EXPOSURES; ORGANIC-COMPOUNDS; OFFICE WORKERS; OUTDOOR AIR; INDOOR; URBAN; QUALITY; POLLUTANTS;
D O I
10.1016/j.buildenv.2014.05.032
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
PM2.5 and NO2 concentrations were measured simultaneously indoors and outdoors for ten different city centre buildings (shops and offices) in Dublin, Ireland. Outdoor concentrations were measured in two locations either at ground level outside the building or at the air intake of the building's ventilation system. The ratio of indoor to outdoor (I/O) PM2.5 concentrations were all found to be close to or above 1, indicating that either the fabric and/or operational environment of the buildings, whether naturally or mechanically ventilated, was not performing any significant function to reduce particulate concentrations from outdoors or that indoor sources were present. Indoor PM2.5 concentrations during working hours were generally below 25 i.tg I11-3 PM2.5, with naturally ventilated shops showing the highest concentrations. Lower indoor NO2 concentrations were measured during working hours in naturally ventilated buildings compared to the mechanically ventilated buildings, although most buildings showed strong diurnal relationships between outdoor NO2 concentrations and indoor air quality. Indeed, street level concentrations of NO2 seemed to have a stronger influence on the indoor air quality of the mechanically ventilated buildings, than with the corresponding air quality measured at their roof level ventilation intakes. The buildings with the greatest reduction for NO2 were older naturally ventilated offices. I/O ratios of both pollutants, but particularly NO2, increased significantly overnight as outdoor concentrations reduced to a much greater extent than indoors. This would indicate a benefit in promoting increased air exchange between the outdoors and indoors during night time periods in order to flush out air pollutants. (C) 2014 Elsevier Ltd. All rights reserved.
引用
收藏
页码:159 / 173
页数:15
相关论文
共 50 条
  • [31] Comprehensive Analysis of PM2.5 Concentrations in the Seoul Metro Underground Stations: Relationships with Indoor Sources and Outdoor Air QualityComprehensive Analysis of PM2.5 Concentrations in the Seoul Metro Underground Stations: Relationships with Indoor Sources and Outdoor Air QualityH.-R. Oh et al.
    Hye-Ryun Oh
    Doo-Sun R. Park
    Hye-Young Ko
    Jihoon Seo
    Minseok Lee
    Woosuk Choi
    Asia-Pacific Journal of Atmospheric Sciences, 2025, 61 (1)
  • [32] Indoor/outdoor relationships for ambient PM2.5 and associated pollutants:: Epidemiological implications in Lindon, Utah
    Patterson, E
    Eatough, DJ
    JOURNAL OF THE AIR & WASTE MANAGEMENT ASSOCIATION, 2000, 50 (01): : 103 - 110
  • [33] Air Pollution Concentrations of PM2.5, PM10 and NO2 at Ambient and Kerbsite and Their Correlation in Metro City – Mumbai
    Rakesh Kumar
    Abba Elizabeth Joseph
    Environmental Monitoring and Assessment, 2006, 119 : 191 - 199
  • [34] Effect of indoor and outdoor emission sources on the chemical compositions of PM2.5 and PM0.1 in residential and school buildings
    Huyen, Truong-Thi
    Sekiguchi, Kazuhiko
    Nghiem, Trung-Dung
    Ly, Bich-Thuy
    AIR QUALITY ATMOSPHERE AND HEALTH, 2024, 17 (07): : 1435 - 1450
  • [35] Air pollution concentrations of PM2.5, PM10 and NO2 at ambient and kerbsite and their correlation in Metro City -: Mumbai
    Kumar, Rakesh
    Joseph, Abba Elizabeth
    ENVIRONMENTAL MONITORING AND ASSESSMENT, 2006, 119 (1-3) : 191 - 199
  • [36] Does the elemental composition of indoor and outdoor PM2.5 accurately represent the elemental composition of personal PM2.5?
    Brokamp, Cole
    Rao, M. B.
    Fan, Zhihua
    Ryan, Patrick H.
    ATMOSPHERIC ENVIRONMENT, 2015, 101 : 226 - 234
  • [37] Clearing the Air: Indoor and outdoor PM2.5 exposure in Moderate-Late Preterm Infants
    Tsang, Kishan
    Pos, Jayanti
    Hoffman-Haringsma, Angelique
    Pijnenburg, Marielle
    Tramper-Stranders, Gerdien
    De Kleer, Isme
    EUROPEAN RESPIRATORY JOURNAL, 2024, 64
  • [38] Residential building ventilation in situations with outdoor PM2.5 pollution
    Liu, Sumei
    Song, Rui
    Zhang, Tengfei
    BUILDING AND ENVIRONMENT, 2021, 202
  • [39] INDOOR PM1, PM2.5, PM10 AND OUTDOOR PM2.5 CONCENTRATIONS IN PRIMARY SCHOOLS IN SARI, IRAN
    Mohammadyan, Mahmoud
    Shabankhani, Bijan
    ARHIV ZA HIGIJENU RADA I TOKSIKOLOGIJU-ARCHIVES OF INDUSTRIAL HYGIENE AND TOXICOLOGY, 2013, 64 (03): : 371 - 377
  • [40] Indoor-outdoor relationships and infiltration behavior of elemental components of outdoor PM2.5 for Boston-area homes
    Long, CM
    Sarnat, JA
    AEROSOL SCIENCE AND TECHNOLOGY, 2004, 38 : 91 - 104