PM2.5 and NO2 concentrations were measured simultaneously indoors and outdoors for ten different city centre buildings (shops and offices) in Dublin, Ireland. Outdoor concentrations were measured in two locations either at ground level outside the building or at the air intake of the building's ventilation system. The ratio of indoor to outdoor (I/O) PM2.5 concentrations were all found to be close to or above 1, indicating that either the fabric and/or operational environment of the buildings, whether naturally or mechanically ventilated, was not performing any significant function to reduce particulate concentrations from outdoors or that indoor sources were present. Indoor PM2.5 concentrations during working hours were generally below 25 i.tg I11-3 PM2.5, with naturally ventilated shops showing the highest concentrations. Lower indoor NO2 concentrations were measured during working hours in naturally ventilated buildings compared to the mechanically ventilated buildings, although most buildings showed strong diurnal relationships between outdoor NO2 concentrations and indoor air quality. Indeed, street level concentrations of NO2 seemed to have a stronger influence on the indoor air quality of the mechanically ventilated buildings, than with the corresponding air quality measured at their roof level ventilation intakes. The buildings with the greatest reduction for NO2 were older naturally ventilated offices. I/O ratios of both pollutants, but particularly NO2, increased significantly overnight as outdoor concentrations reduced to a much greater extent than indoors. This would indicate a benefit in promoting increased air exchange between the outdoors and indoors during night time periods in order to flush out air pollutants. (C) 2014 Elsevier Ltd. All rights reserved.
引用
收藏
页码:159 / 173
页数:15
相关论文
共 50 条
  • [11] Relationships between personal, indoor, and outdoor exposures to trace elements in PM2.5
    Adgate, John L.
    Mongin, Steven J.
    Pratt, Gregory C.
    Zhang, Junfeng
    Field, M. Paul
    Ramachandran, Gurumurthy
    Sexton, Ken
    SCIENCE OF THE TOTAL ENVIRONMENT, 2007, 386 (1-3) : 21 - 32
  • [12] Intra-urban variability of air pollution:: Monitoring and modelling of PM2.5, PM2.5-10, and NO2
    Wheeler, A.
    Xu, X.
    Smith-Doiron, M.
    Gilbert, N.
    Brook, J.
    EPIDEMIOLOGY, 2006, 17 (06) : S243 - S243
  • [13] Indoor and outdoor PM2.5 and PM10 concentrations in the air during a dust storm
    Kuo, Hsien-Wen
    Shen, Huna-Yi
    BUILDING AND ENVIRONMENT, 2010, 45 (03) : 610 - 614
  • [14] Indoor and outdoor concentrations of PM2.5, soot and NO2 at homes, pre-schools and schools in Sweden
    Wichmann, J.
    Bellander, T.
    Nilsson, M. A. M.
    EPIDEMIOLOGY, 2006, 17 (06) : S467 - S468
  • [15] Differences in indoor versus outdoor concentrations of ultrafine particles, PM2.5, PMabsorbance and NO2 in Swiss homes
    Reto Meier
    Marloes Eeftens
    Harish C Phuleria
    Alex Ineichen
    Elisabetta Corradi
    Mark Davey
    Martin Fierz
    Regina E Ducret-Stich
    Inmaculada Aguilera
    Christian Schindler
    Thierry Rochat
    Nicole Probst-Hensch
    Ming-Yi Tsai
    Nino Künzli
    Journal of Exposure Science & Environmental Epidemiology, 2015, 25 : 499 - 505
  • [16] Differences in indoor versus outdoor concentrations of ultrafine particles, PM2.5, PMabsorbance and NO2 in Swiss homes
    Meier, Reto
    Eeftens, Marloes
    Phuleria, Harish C.
    Ineichen, Alex
    Corradi, Elisabetta
    Davey, Mark
    Fierz, Martin
    Ducret-Stich, Regina E.
    Aguilera, Lnmaculada
    Schindler, Christian
    Rochat, Thierry
    Probst-Hensch, Nicole
    Tsai, Ming-Yi
    Kuenzli, Nino
    JOURNAL OF EXPOSURE SCIENCE AND ENVIRONMENTAL EPIDEMIOLOGY, 2015, 25 (05) : 499 - 505
  • [17] The analysis of PM2.5 and associated elements and their indoor/outdoor pollution status in an urban area
    Lim, J. -M.
    Jeong, J. -H.
    Lee, J. -H.
    Moon, J. -H.
    Chung, Y. -S.
    Kim, K. -H.
    INDOOR AIR, 2011, 21 (02) : 145 - 155
  • [18] Relationship between Outdoor and Indoor PM10,PM2.5 and PM1 in Apartment and Office Buildings
    文远高
    连之伟
    叶晓江
    兰丽
    JournalofDonghuaUniversity(EnglishEdition), 2008, (03) : 334 - 339
  • [19] Indoor/outdoor PM10 and PM2.5 in Bangkok, Thailand
    FENG C TSAI
    KIRK R SMITH
    NUNTAVARN VICHIT-VADAKAN
    BART D OSTRO
    LAURAINE G CHESTNUT
    NIPAPUN KUNGSKULNITI
    Journal of Exposure Science & Environmental Epidemiology, 2000, 10 : 15 - 26
  • [20] Indoor/outdoor PM10 and PM2.5 in Bangkok, Thailand
    Tsai, FC
    Smith, KR
    Vichit-Vadakan, N
    Ostro, BD
    Chestnut, LG
    Kungskulniti, N
    JOURNAL OF EXPOSURE ANALYSIS AND ENVIRONMENTAL EPIDEMIOLOGY, 2000, 10 (01): : 15 - 26