Highly Sensitive Electrochemical Biosensor Using Folic Acid-Modified Reduced Graphene Oxide for the Detection of Cancer Biomarker

被引:31
|
作者
Geetha Bai, Renu [1 ,2 ]
Muthoosamy, Kasturi [1 ]
Tuvikene, Rando [2 ]
Nay Ming, Huang [3 ]
Manickam, Sivakumar [1 ,4 ]
机构
[1] Univ Nottingham Malaysia, Dept Chem & Environm Engn, Nanotechnol Res Grp, Fac Engn, Semenyih 43500, Malaysia
[2] Tallinn Univ, Sch Nat Sci & Hlth, EE-10120 Tallinn, Estonia
[3] Xiamen Univ Malaysia, Sch Energy & Chem Engn, New Energy Sci & Engn, Sepang 43900, Malaysia
[4] Univ Teknol Brunei, Petr & Chem Engn, Fac Engn, BE-1410 Bandar Seri Begawan, Brunei
关键词
folic acid; folate receptor; folate targeted; electrochemical sensor; cancer biomarker; rGO-FA; differential pulse voltammetry; biosensor; FOLATE RECEPTOR-ALPHA; TERMINAL PROTECTION; FUNCTIONALIZED GRAPHENE; GOLD NANOPARTICLES; THERMAL-STABILITY; QUANTUM DOTS; IN-VITRO; CELL; DELIVERY; DRUG;
D O I
10.3390/nano11051272
中图分类号
O6 [化学];
学科分类号
0703 ;
摘要
The detection of cancer biomarkers in the early stages could prevent cancer-related deaths significantly. Nanomaterials combined with biomolecules are extensively used in drug delivery, imaging, and sensing applications by targeting the overexpressed cancer proteins such as folate receptors (FRs) to control the disease by providing earlier treatments. In this investigation, biocompatible reduced graphene oxide (rGO) nanosheets combined with folic acid (FA)-a vitamin with high bioaffinity to FRs-is utilized to develop an electrochemical sensor for cancer detection. To mimic the cancer cell environment, FR-beta protein is used to evaluate the response of the rGO-FA sensor. The formation of the rGO-FA nanocomposite was confirmed through various characterization techniques. A glassy carbon (GC) electrode was then modified with the obtained rGO-FA and analyzed via differential pulse voltammetry (DPV) for its specific detection towards FRs. Using the DPV technique, the rGO-FA-modified electrode exhibited a limit of detection (LOD) of 1.69 pM, determined in a linear concentration range from 6 to 100 pM. This excellent electrochemical performance towards FRs detection could provide a significant contribution towards future cancer diagnosis. Moreover, the rGO-FA sensing platform also showed excellent specificity and reliability when tested against similar interfering biomolecules. This rGO-FA sensor offers a great promise to the future medical industry through its highly sensitive detection towards FRs in a fast, reliable, and economical way.
引用
收藏
页数:15
相关论文
共 50 条
  • [21] Electrochemical biosensing based on folic acid-triazine-grafted reduced graphene oxide: a highly selective breast cancer cell sensor
    Yari, Abdollah
    Shokri, Foroozan
    [J]. ANALYTICAL METHODS, 2023, 15 (33) : 4134 - 4141
  • [22] Gold nanoparticles/single-stranded DNA-reduced graphene oxide nanocomposites based electrochemical biosensor for highly sensitive detection of cholesterol
    Shuyao Wu
    Chengquan Sui
    Chong Wang
    Yulu Wang
    Dongqing He
    Ying Sun
    Yu Zhang
    Qingbo Meng
    Tianyi Ma
    XiMing Song
    [J]. Frontiers of Chemical Science and Engineering, 2021, 15 (06) : 1572 - 1582
  • [23] Gold nanoparticles/single-stranded DNA-reduced graphene oxide nanocomposites based electrochemical biosensor for highly sensitive detection of cholesterol
    Shuyao Wu
    Chengquan Sui
    Chong Wang
    Yulu Wang
    Dongqing He
    Ying Sun
    Yu Zhang
    Qingbo Meng
    Tianyi Ma
    Xi-Ming Song
    [J]. Frontiers of Chemical Science and Engineering, 2021, 15 : 1572 - 1582
  • [24] Gold nanoparticles/single-stranded DNA-reduced graphene oxide nanocomposites based electrochemical biosensor for highly sensitive detection of cholesterol
    Wu, Shuyao
    Sui, Chengquan
    Wang, Chong
    Wang, Yulu
    He, Dongqing
    Sun, Ying
    Zhang, Yu
    Meng, Qingbo
    Ma, Tianyi
    Song, Xi-Ming
    [J]. FRONTIERS OF CHEMICAL SCIENCE AND ENGINEERING, 2021, 15 (06) : 1572 - 1582
  • [25] Electrochemical detection of 17β-estradiol and bisphenol A using graphene oxide and reduced graphene oxide modified electrodes: A review
    Baez, Marcelo Lopez
    Garcia, Alejandra
    Martinez, Ivan
    Gonzalez, Christopher
    Gomez, Marisol
    Rodriguez, Barbara
    [J]. INTERNATIONAL JOURNAL OF ELECTROCHEMICAL SCIENCE, 2024, 19 (04):
  • [26] Reduced graphene oxide modified smart conducting paper for cancer biosensor
    Kumar, Saurabh
    Kumar, Suveen
    Srivastava, Saurabh
    Yadav, Birendra K.
    Lee, Seung H.
    Sharma, Jai G.
    Doval, Dinesh C.
    Malhotra, Bansi D.
    [J]. BIOSENSORS & BIOELECTRONICS, 2015, 73 : 114 - 122
  • [27] Highly sensitive electrochemical biosensor based on naturally reduced rGO/Au nanocomposite for the detection of miRNA-122 biomarker
    Kasturi, Satish
    Eom, Yunji
    Torati, Sri Ramulu
    Kim, CheolGi
    [J]. JOURNAL OF INDUSTRIAL AND ENGINEERING CHEMISTRY, 2021, 93 : 186 - 195
  • [28] A highly sensitive electrochemical biosensor based on zinc oxide nanotetrapods for L-lactic acid detection
    Lei, Yang
    Luo, Ning
    Yan, Xiaoqin
    Zhao, Yanguang
    Zhang, Gong
    Zhang, Yue
    [J]. NANOSCALE, 2012, 4 (11) : 3438 - 3443
  • [29] Electrochemical detection of selenium using glassy carbon electrode modified with reduced graphene oxide
    Idris, Azeez O.
    Mabuba, Nonhlangabezo
    Nkosi, Duduzile
    Maxakato, Nobanathi
    Arotiba, Omotayo A.
    [J]. INTERNATIONAL JOURNAL OF ENVIRONMENTAL ANALYTICAL CHEMISTRY, 2017, 97 (06) : 534 - 547