Highly Sensitive Electrochemical Biosensor Using Folic Acid-Modified Reduced Graphene Oxide for the Detection of Cancer Biomarker

被引:31
|
作者
Geetha Bai, Renu [1 ,2 ]
Muthoosamy, Kasturi [1 ]
Tuvikene, Rando [2 ]
Nay Ming, Huang [3 ]
Manickam, Sivakumar [1 ,4 ]
机构
[1] Univ Nottingham Malaysia, Dept Chem & Environm Engn, Nanotechnol Res Grp, Fac Engn, Semenyih 43500, Malaysia
[2] Tallinn Univ, Sch Nat Sci & Hlth, EE-10120 Tallinn, Estonia
[3] Xiamen Univ Malaysia, Sch Energy & Chem Engn, New Energy Sci & Engn, Sepang 43900, Malaysia
[4] Univ Teknol Brunei, Petr & Chem Engn, Fac Engn, BE-1410 Bandar Seri Begawan, Brunei
关键词
folic acid; folate receptor; folate targeted; electrochemical sensor; cancer biomarker; rGO-FA; differential pulse voltammetry; biosensor; FOLATE RECEPTOR-ALPHA; TERMINAL PROTECTION; FUNCTIONALIZED GRAPHENE; GOLD NANOPARTICLES; THERMAL-STABILITY; QUANTUM DOTS; IN-VITRO; CELL; DELIVERY; DRUG;
D O I
10.3390/nano11051272
中图分类号
O6 [化学];
学科分类号
0703 ;
摘要
The detection of cancer biomarkers in the early stages could prevent cancer-related deaths significantly. Nanomaterials combined with biomolecules are extensively used in drug delivery, imaging, and sensing applications by targeting the overexpressed cancer proteins such as folate receptors (FRs) to control the disease by providing earlier treatments. In this investigation, biocompatible reduced graphene oxide (rGO) nanosheets combined with folic acid (FA)-a vitamin with high bioaffinity to FRs-is utilized to develop an electrochemical sensor for cancer detection. To mimic the cancer cell environment, FR-beta protein is used to evaluate the response of the rGO-FA sensor. The formation of the rGO-FA nanocomposite was confirmed through various characterization techniques. A glassy carbon (GC) electrode was then modified with the obtained rGO-FA and analyzed via differential pulse voltammetry (DPV) for its specific detection towards FRs. Using the DPV technique, the rGO-FA-modified electrode exhibited a limit of detection (LOD) of 1.69 pM, determined in a linear concentration range from 6 to 100 pM. This excellent electrochemical performance towards FRs detection could provide a significant contribution towards future cancer diagnosis. Moreover, the rGO-FA sensing platform also showed excellent specificity and reliability when tested against similar interfering biomolecules. This rGO-FA sensor offers a great promise to the future medical industry through its highly sensitive detection towards FRs in a fast, reliable, and economical way.
引用
收藏
页数:15
相关论文
共 50 条
  • [31] Simultaneous electrochemical detection of dopamine and ascorbic acid using an iron oxide/reduced graphene oxide modified glassy carbon electrode
    Peik-See, Teo
    Pandikumar, Alagarsamy
    Nay-Ming, Huang
    Hong-Ngee, Lim
    Sulaiman, Yusran
    [J]. Sensors (Switzerland), 2014, 14 (08): : 15227 - 15243
  • [32] Simultaneous Electrochemical Detection of Dopamine and Ascorbic Acid Using an Iron Oxide/Reduced Graphene Oxide Modified Glassy Carbon Electrode
    Peik-See, Teo
    Pandikumar, Alagarsamy
    Nay-Ming, Huang
    Hong-Ngee, Lim
    Sulaiman, Yusran
    [J]. SENSORS, 2014, 14 (08): : 15227 - 15243
  • [33] Highly sensitive detection of fluoride based on poly(3-aminophenylboronic acid)-reduced graphene oxide multilayer modified electrode
    Wang, Shurong
    Wang, Haohao
    Liu, Shuqin
    Guo, Hongyuan
    Meng, Junlong
    Chang, Mingchang
    Wu, Suozhu
    [J]. FOOD CHEMISTRY, 2023, 400
  • [34] A Simple DNA-based Electrochemical Biosensor for Highly Sensitive Detection of Ciprofloxacin Using Disposable Graphene
    Lim, Syazana A.
    Ahmed, Minhaz U.
    [J]. ANALYTICAL SCIENCES, 2016, 32 (06) : 687 - 693
  • [35] Reduced Graphene Oxide Electrically Contacted Graphene Sensor for Highly Sensitive Nitric Oxide Detection
    Li, Weiwei
    Geng, Xiumei
    Guo, Yufen
    Rong, Jizan
    Gong, Youpin
    Wu, Liqiong
    Zhang, Xuemin
    Li, Peng
    Xu, Jianbao
    Cheng, Guosheng
    Sun, Mengtao
    Liu, Liwei
    [J]. ACS NANO, 2011, 5 (09) : 6955 - 6961
  • [36] Highly manufacturable graphene oxide biosensor for sensitive Interleukin-6 detection
    Huang, Jingfeng
    Chen, Hu
    Niu, Wenbin
    Fam, Derrick W. H.
    Palaniappan, Alagappan
    Larisika, Melanie
    Faulkner, Steve H.
    Nowak, Christoph
    Nimmo, Myra A.
    Liedberg, Bo
    Tok, Alfred I. Y.
    [J]. RSC ADVANCES, 2015, 5 (49) : 39245 - 39251
  • [37] A Simple DNA-based Electrochemical Biosensor for Highly Sensitive Detection of Ciprofloxacin Using Disposable Graphene
    Syazana A. Lim
    Minhaz U. Ahmed
    [J]. Analytical Sciences, 2016, 32 : 687 - 693
  • [38] Detection of SARS-CoV-2 in clinical and environmental samples using highly sensitive reduced graphene oxide (rGO)-based biosensor
    Kadadou, Dana
    Tizani, Lina
    Wadi, Vijay S.
    Banat, Fawzi
    Alsafar, Habiba
    Yousef, Ahmed F.
    Hasan, Shadi W.
    [J]. CHEMICAL ENGINEERING JOURNAL, 2023, 453
  • [39] Sensitive detection of uric acid on partially electro-reduced graphene oxide modified electrodes
    Zhang, Ziping
    Yin, Jungang
    [J]. ELECTROCHIMICA ACTA, 2014, 119 : 32 - 37
  • [40] Highly Sensitive Electrochemical Detection of Azithromycin with Graphene-Modified Electrode
    Pogacean, Florina
    Varodi, Codruta
    Magerusan, Lidia
    Stefan-van Staden, Raluca-Ioana
    Pruneanu, Stela
    [J]. SENSORS, 2022, 22 (16)