Simultaneous electrochemical detection of dopamine and ascorbic acid using an iron oxide/reduced graphene oxide modified glassy carbon electrode

被引:0
|
作者
机构
[1] Peik-See, Teo
[2] Pandikumar, Alagarsamy
[3] Nay-Ming, Huang
[4] Hong-Ngee, Lim
[5] Sulaiman, Yusran
来源
关键词
Cyclic voltammetry - Graphene - Amines - Chemical detection - Electrochemical biosensors - Electrocatalysis - Glass - Glass membrane electrodes - Ascorbic acid - Neurophysiology;
D O I
暂无
中图分类号
学科分类号
摘要
The fabrication of an electrochemical sensor based on an iron oxide/graphene modified glassy carbon electrode (Fe3O4/rGO/GCE) and its simultaneous detection of dopamine (DA) and ascorbic acid (AA) is described here. The Fe3O4/rGO nanocomposite was synthesized via a simple, one step in-situ wet chemical method and characterized by different techniques. The presence of Fe3O4 nanoparticles on the surface of rGO sheets was confirmed by FESEM and TEM images. The electrochemical behavior of Fe3O4/rGO/GCE towards electrocatalytic oxidation of DA was investigated by cyclic voltammetry (CV) and differential pulse voltammetry (DPV) analysis. The electrochemical studies revealed that the Fe3O4/rGO/GCE dramatically increased the current response against the DA, due to the synergistic effect emerged between Fe3O4 and rGO. This implies that Fe3O4/rGO/GCE could exhibit excellent electrocatalytic activity and remarkable electron transfer kinetics towards the oxidation of DA. Moreover, the modified sensor electrode portrayed sensitivity and selectivity for simultaneous determination of AA and DA. The observed DPVs response linearly depends on AA and DA concentration in the range of 1–9 mM and 0.5–100 μM, with correlation coefficients of 0.995 and 0.996, respectively. The detection limit of (S/N = 3) was found to be 0.42 and 0.12 μM for AA and DA, respectively. © 2014 by the authors; licensee MDPI, Basel, Switzerland.
引用
收藏
相关论文
共 50 条
  • [1] Simultaneous electrochemical detection of dopamine and ascorbic acid using an iron oxide/reduced graphene oxide modified glassy carbon electrode
    Peik-See, Teo
    Pandikumar, Alagarsamy
    Nay-Ming, Huang
    Hong-Ngee, Lim
    Sulaiman, Yusran
    [J]. Sensors (Switzerland), 2014, 14 (08): : 15227 - 15243
  • [2] Simultaneous Electrochemical Detection of Dopamine and Ascorbic Acid Using an Iron Oxide/Reduced Graphene Oxide Modified Glassy Carbon Electrode
    Peik-See, Teo
    Pandikumar, Alagarsamy
    Nay-Ming, Huang
    Hong-Ngee, Lim
    Sulaiman, Yusran
    [J]. SENSORS, 2014, 14 (08): : 15227 - 15243
  • [3] Simultaneous determination of dopamine, uric acid and ascorbic acid using a glassy carbon electrode modified with reduced graphene oxide
    Wang, Huiwen
    Ren, Fangfang
    Wang, Caiqin
    Yang, Beibei
    Bin, Duan
    Zhang, Ke
    Du, Yukou
    [J]. RSC ADVANCES, 2014, 4 (51) : 26895 - 26901
  • [4] A Facile Electrochemical Fabrication of Reduced Graphene Oxide-Modified Glassy Carbon Electrode for Simultaneous Detection of Dopamine, Ascorbic Acid, and Uric Acid
    Yu, Joonhee
    Kim, Tae Hyun
    [J]. JOURNAL OF ELECTROCHEMICAL SCIENCE AND TECHNOLOGY, 2017, 8 (04) : 274 - 281
  • [5] A facile electrochemical sensor based on reduced graphene oxide and Au nanoplates modified glassy carbon electrode for simultaneous detection of ascorbic acid, dopamine and uric acid
    Wang, Caiqin
    Du, Jiao
    Wang, Huiwen
    Zou, Cui'e
    Jiang, Fengxing
    Yang, Ping
    Du, Yukou
    [J]. SENSORS AND ACTUATORS B-CHEMICAL, 2014, 204 : 302 - 309
  • [6] SIMULTANEOUS ELECTROCHEMICAL DETECTION OF ASCORBIC ACID, DOPAMINE, AND URIC ACID AT MAGNETIC NANOPARTICLES/REDUCED GRAPHENE OXIDE MODIFIED ELECTRODE
    Rosli, Azleen Rashidah Mohd
    Yusoff, Farhanini
    Loh, Saw Hong
    Yusoff, Hanis Mohd
    Jamil, Muhammad Mahadi Abdul
    Shamsudin, Shazrul Hasry
    [J]. JURNAL TEKNOLOGI-SCIENCES & ENGINEERING, 2021, 83 (03): : 85 - 92
  • [7] Simultaneous electrochemical determination of ascorbic acid, dopamine and uric acid based on reduced graphene oxide-Ag/PANI modified glassy carbon electrode
    Zhuo Guo
    Xianke Luo
    Yahui Li
    Dongdi Li
    Qinai Zhao
    Mengmeng Li
    Chi Ma
    Yanting Zhao
    [J]. Chemical Research in Chinese Universities, 2017, 33 : 507 - 512
  • [8] Simultaneous Electrochemical Determination of Ascorbic Acid, Dopamine and Uric Acid Based on Reduced Graphene Oxide-Ag/PANI Modified Glassy Carbon Electrode
    Guo Zhuo
    Luo Xianke
    Li Yahui
    Li Dongdi
    Zhao Qinai
    Li Mengmeng
    Ma Chi
    Zhao Yanting
    [J]. CHEMICAL RESEARCH IN CHINESE UNIVERSITIES, 2017, 33 (03) : 507 - 512
  • [9] Electrochemical detection of selenium using glassy carbon electrode modified with reduced graphene oxide
    Idris, Azeez O.
    Mabuba, Nonhlangabezo
    Nkosi, Duduzile
    Maxakato, Nobanathi
    Arotiba, Omotayo A.
    [J]. INTERNATIONAL JOURNAL OF ENVIRONMENTAL ANALYTICAL CHEMISTRY, 2017, 97 (06) : 534 - 547
  • [10] A glassy carbon electrode modified with a nanocomposite consisting of MoS2 and reduced graphene oxide for electrochemical simultaneous determination of ascorbic acid, dopamine, and uric acid
    Liwen Xing
    Zhanfang Ma
    [J]. Microchimica Acta, 2016, 183 : 257 - 263