Ambient dose equivalent measurement with a CsI(Tl) based electronic personal dosimeter

被引:13
|
作者
Park, Kyeongjin [1 ]
Kim, Jinhwan [1 ]
Lim, Kyung Taek [1 ]
Kim, Junhyeok [1 ]
Chang, Hojong [2 ]
Kim, Hyunduk [3 ]
Sharma, Manish [4 ]
Cho, Gyuseong [1 ]
机构
[1] Korea Adv Inst Sci & Technol, Dept Nucl & Quantum Engn, 291 Daehak Ro, Daejeon 34141, South Korea
[2] Korea Adv Inst Sci & Technol, Inst Informat Technol Convergence, 291 Daehak Ro, Daejeon 34141, South Korea
[3] Iris Co Ltd, 193 Munji Ro, Daejeon 34051, South Korea
[4] Khalifa Univ, Dept Nucl Engn, Abu Dhabi 127788, U Arab Emirates
关键词
Electronic personal dosimeter; Ambient dose equivalent; G(E) function; PIN diode; CsI(Tl) scintillator; SILICON PHOTOMULTIPLIER; H-ASTERISK(10); NAI(TL);
D O I
10.1016/j.net.2019.06.017
中图分类号
TL [原子能技术]; O571 [原子核物理学];
学科分类号
0827 ; 082701 ;
摘要
In this manuscript, we present a method for the direct calculation of an ambient dose equivalent (H*(10)) for the external gamma-ray exposure with an energy range of 40 keV to 2 MeV in an electronic personal dosimeter (EPD). The designed EPD consists of a 3 x 3 mm(2) PIN diode coupled to a 3 x 3 x 3 mm(3) CsI (TI) scintillator block. The spectrum-to-dose conversion function (G(E)) for estimating H*(10) was calculated by applying the gradient-descent method based on the Monte-Carlo simulation. The optimal parameters for the G(E) were found and this conversion of the H*(10) from the gamma spectra was Am-241, Cs-137, (22) Na, Mn-54, Co-60 verified by using and Co radioisotopes. Furthermore, gamma spectra and H*(10) were obtained for an arbitrarily mixed multiple isotope case through Monte-Carlo simulation in order to expand the verification to more general cases. The H*(10) based on the G(E) function for the gamma spectra was then compared with H*(10) calculated by simulation. The relative difference of H*(10) from various single-source spectra was in the range of +/- 2.89%, and the relative difference of H*(10) for a multiple isotope case was in the range of +/- 5.56%. (C) 2019 Korean Nuclear Society, Published by Elsevier Korea LLC.
引用
收藏
页码:1991 / 1997
页数:7
相关论文
共 50 条
  • [41] The use of a Monte Carlo method for uncertainty calculation, with an application to the measurement of neutron ambient dose equivalent rate
    Cox, Maurice
    Harris, Peter
    Nam, Gyeonghee
    Thomas, David
    [J]. RADIATION PROTECTION DOSIMETRY, 2006, 121 (01) : 12 - 23
  • [42] MEASUREMENT OF NEUTRON AMBIENT DOSE EQUIVALENT IN CARBON-ION RADIOTHERAPY WITH AN ACTIVE SCANNED DELIVERY SYSTEM
    Yonai, S.
    Furukawa, T.
    Inaniwa, T.
    [J]. RADIATION PROTECTION DOSIMETRY, 2014, 161 (1-4) : 433 - 436
  • [43] Measurement of Neutron Spectrum and Ambient Dose Equivalent Around a Mini-Phantom at a Proton Therapy Facility
    Wang, Z.
    Kry, S.
    Burgett, E.
    Howell, R.
    Tailor, R.
    Oliver, J.
    Followill, D.
    Smith, A.
    Salehpour, M.
    [J]. MEDICAL PHYSICS, 2008, 35 (06)
  • [44] National Calibration and Measurement Capabilities (CMCs) at the ININ for Air Kerma Rate (K) over dota, Personal Equivalent Dose Hp(10) and Ambient Equivalent Dose H*(10) in the 137Cs Energy for Radiological Protection Applications
    Cabrera Vertti, Mario R.
    Alvarez Romero, Jose T.
    Tovar Munoz, Victor. M.
    de la Cruz Hernandez, Daniel
    [J]. MEDICAL PHYSICS: FOURTEENTH MEXICAN SYMPOSIUM ON MEDICAL PHYSICS, 2016, 1747
  • [45] Low and high dose measurement by Agfa personal monitoring film and FD-III-B badge dosimeter system
    Mihai, F.
    Bercea, S.
    Stochioiu, A.
    Celarel, A.
    Udup, E.
    Tudor, I.
    [J]. APPLIED RADIATION AND ISOTOPES, 2010, 68 (4-5) : 614 - 616
  • [46] Comparison of the performance of two thermoluminescent dosimetry systems for the personal dose-equivalent Hp(10) measurement
    Lu, Fengfan
    Li, Wei
    Jin, Jing
    Li, Kui
    Zhou, Jinghua
    [J]. RADIATION PROTECTION DOSIMETRY, 2024, 200 (05) : 481 - 486
  • [47] A prototype ionisation chamber as a secondary standard for the measurement of personal dose equivalent, Hp(10), on a slab phantom
    Ankerhold, U
    Behrens, R
    Ambrosi, P
    [J]. RADIATION PROTECTION DOSIMETRY, 1999, 86 (03) : 167 - 173
  • [48] UNCERTAINTY EVALUATION IN MEASUREMENT OF THE PERSONAL DOSE EQUIVALENT AT NINE INDIVIDUAL MONITORING SERVICES IN ASIA AND THE PACIFIC REGION
    Rizk, Chadia
    Askounis, Panagiotis
    Okyar, H. Burcin
    Sangau, John Konsoh
    Baradaran, Samaneh
    Al Fares, Elham
    Shah, Buddha R.
    Munkhtsetseg, Baldandorj
    Mitrayon, Leeda
    Rathnayake, Muditha
    Ali, Mohamed
    [J]. RADIATION PROTECTION DOSIMETRY, 2020, 190 (02) : 217 - 225
  • [49] MEASUREMENT OF NEUTRON AMBIENT DOSE EQUIVALENT IN PROTON RADIOTHERAPY WITH LINE-SCANNING AND WOBBLING MODE TREATMENT SYSTEM
    Lee, Sangmin
    Lee, Chaeyeong
    Shin, Eun Hyuk
    Cho, Sungkoo
    Kim, Dae-Hyun
    Han, Youngyih
    Choi, Doo Ho
    Ye, Sung-Joon
    Kim, Jin Sung
    [J]. RADIATION PROTECTION DOSIMETRY, 2017, 177 (04) : 382 - 388
  • [50] A SECONDARY STANDARD IONIZATION-CHAMBER FOR THE DIRECT MEASUREMENT OF AMBIENT DOSE EQUIVALENT H-STAR(10)
    DUFTSCHMID, KE
    HIZO, J
    STRACHOTINSKY, C
    [J]. RADIATION PROTECTION DOSIMETRY, 1992, 40 (01) : 35 - 38