In ion beam radiotherapy, secondary neutrons contribute to an undesired dose outside the target volume, and consequently the increase of secondary cancer risk is a growing concern. In this study, neutron ambient dose equivalents in carbon-ion radiotherapy (CIRT) with an active beam delivery system were measured with a rem meter, WENDI-II, at National Institute of Radiological Sciences. When the same irradiation target was assumed, the measured neutron dose with an active beam was at most similar to 15 % of that with a passive beam. This percentage became smaller as larger distances from the iso-centre. Also, when using an active beam delivery system, the neutron dose per treatment dose in CIRT was comparable with that in proton radiotherapy. Finally, it was experimentally demonstrated that the use of an active scanned beam in CIRT can greatly reduce the secondary neutron dose.
引用
收藏
页码:433 / 436
页数:4
相关论文
共 50 条
  • [1] EVALUATION OF NEUTRON AMBIENT DOSE EQUIVALENT IN CARBON-ION RADIOTHERAPY WITH ENERGY SCANNING
    Matsumoto, Shinnosuke
    Yonai, Shunsuke
    [J]. RADIATION PROTECTION DOSIMETRY, 2020, 191 (03) : 310 - 318
  • [2] Measurement of neutron ambient dose equivalent in passive carbon-ion and proton radiotherapies
    Yonai, Shunsuke
    Matsufuji, Naruhiro
    Kanai, Tatsuaki
    Matsui, Yuki
    Matsushita, Kaoru
    Yamashita, Haruo
    Numano, Masumi
    Sakae, Takeji
    Terunuma, Toshiyuki
    Nishio, Teiji
    Kohno, Ryosuke
    Akagi, Takashi
    [J]. MEDICAL PHYSICS, 2008, 35 (11) : 4782 - 4792
  • [3] Secondary neutron ambient dose equivalent measurement of the wobbling system of a proton beam radiotherapy facility
    Liao, Ying-Lan
    Chen, Hsien-Hsin
    Chen, Hsin-Yu
    Huang, Hsiao-Chieh
    Yeh, Chien-Yi
    Tsai, Hui-Yu
    [J]. RADIATION PHYSICS AND CHEMISTRY, 2017, 137 : 116 - 120
  • [4] Perturbation analysis of 4D dose distribution for scanned carbon-ion beam radiotherapy
    He, Pengbo
    Mori, Shinichiro
    [J]. PHYSICA MEDICA-EUROPEAN JOURNAL OF MEDICAL PHYSICS, 2020, 74 : 74 - 82
  • [5] A trichrome beam model for biological dose calculation in scanned carbon-ion radiotherapy treatment planning
    Inaniwa, T.
    Kanematsu, N.
    [J]. PHYSICS IN MEDICINE AND BIOLOGY, 2015, 60 (01): : 437 - 451
  • [6] Secondary Neutron Dose in Carbon-ion Radiotherapy: Investigations in QST-NIRS
    Yonai, Shunsuke
    Matsumoto, Shinnosuke
    [J]. JOURNAL OF RADIATION PROTECTION AND RESEARCH, 2021, 46 (02): : 39 - 47
  • [7] An analytic model of neutron ambient dose equivalent and equivalent dose for proton radiotherapy
    Zhang, Rui
    Perez-Andujar, Angelica
    Fontenot, Jonas D.
    Taddei, Phillip J.
    Newhauser, Wayne D.
    [J]. PHYSICS IN MEDICINE AND BIOLOGY, 2010, 55 (23): : 6975 - 6985
  • [8] MEASUREMENT OF NEUTRON AMBIENT DOSE EQUIVALENT IN PROTON RADIOTHERAPY WITH LINE-SCANNING AND WOBBLING MODE TREATMENT SYSTEM
    Lee, Sangmin
    Lee, Chaeyeong
    Shin, Eun Hyuk
    Cho, Sungkoo
    Kim, Dae-Hyun
    Han, Youngyih
    Choi, Doo Ho
    Ye, Sung-Joon
    Kim, Jin Sung
    [J]. RADIATION PROTECTION DOSIMETRY, 2017, 177 (04) : 382 - 388
  • [9] Scintillator screen for measuring dose distribution in scanned carbon-ion therapy
    Yogo, Katsunori
    Tatsuno, Yuya
    Souda, Hikaru
    Matsumura, Akihiko
    Tsuneda, Masato
    Hirano, Yoshiyuki
    Ishiyama, Hiromichi
    Saito, Akito
    Ozawa, Shuichi
    Nagata, Yasushi
    Nakano, Takashi
    Hayakawa, Kazushige
    Kanai, Tatsuaki
    [J]. RADIATION MEASUREMENTS, 2019, 129
  • [10] Investigation of acceptance criteria for the gamma-index in scanned carbon-ion radiotherapy
    Lahrmann, S.
    Jakel, O.
    Karger, C. P.
    [J]. RADIOTHERAPY AND ONCOLOGY, 2007, 84 : S232 - S233