Ambient dose equivalent measurement with a CsI(Tl) based electronic personal dosimeter

被引:13
|
作者
Park, Kyeongjin [1 ]
Kim, Jinhwan [1 ]
Lim, Kyung Taek [1 ]
Kim, Junhyeok [1 ]
Chang, Hojong [2 ]
Kim, Hyunduk [3 ]
Sharma, Manish [4 ]
Cho, Gyuseong [1 ]
机构
[1] Korea Adv Inst Sci & Technol, Dept Nucl & Quantum Engn, 291 Daehak Ro, Daejeon 34141, South Korea
[2] Korea Adv Inst Sci & Technol, Inst Informat Technol Convergence, 291 Daehak Ro, Daejeon 34141, South Korea
[3] Iris Co Ltd, 193 Munji Ro, Daejeon 34051, South Korea
[4] Khalifa Univ, Dept Nucl Engn, Abu Dhabi 127788, U Arab Emirates
关键词
Electronic personal dosimeter; Ambient dose equivalent; G(E) function; PIN diode; CsI(Tl) scintillator; SILICON PHOTOMULTIPLIER; H-ASTERISK(10); NAI(TL);
D O I
10.1016/j.net.2019.06.017
中图分类号
TL [原子能技术]; O571 [原子核物理学];
学科分类号
0827 ; 082701 ;
摘要
In this manuscript, we present a method for the direct calculation of an ambient dose equivalent (H*(10)) for the external gamma-ray exposure with an energy range of 40 keV to 2 MeV in an electronic personal dosimeter (EPD). The designed EPD consists of a 3 x 3 mm(2) PIN diode coupled to a 3 x 3 x 3 mm(3) CsI (TI) scintillator block. The spectrum-to-dose conversion function (G(E)) for estimating H*(10) was calculated by applying the gradient-descent method based on the Monte-Carlo simulation. The optimal parameters for the G(E) were found and this conversion of the H*(10) from the gamma spectra was Am-241, Cs-137, (22) Na, Mn-54, Co-60 verified by using and Co radioisotopes. Furthermore, gamma spectra and H*(10) were obtained for an arbitrarily mixed multiple isotope case through Monte-Carlo simulation in order to expand the verification to more general cases. The H*(10) based on the G(E) function for the gamma spectra was then compared with H*(10) calculated by simulation. The relative difference of H*(10) from various single-source spectra was in the range of +/- 2.89%, and the relative difference of H*(10) for a multiple isotope case was in the range of +/- 5.56%. (C) 2019 Korean Nuclear Society, Published by Elsevier Korea LLC.
引用
收藏
页码:1991 / 1997
页数:7
相关论文
共 50 条
  • [21] A NEW TL-DOS NEUTRON DOSEMETER FOR MEASUREMENTS OF THE PERSONAL DOSE EQUIVALENT HP(10)
    Heiny, M.
    Busch, F.
    Kroeninger, K.
    Theinert, R.
    Walbersloh, J.
    [J]. RADIATION PROTECTION DOSIMETRY, 2020, 188 (01) : 8 - 12
  • [22] THE MEASUREMENT OF PRACTICAL RADIATION-FIELDS AND CALCULATION OF AMBIENT AND EFFECTIVE DOSE EQUIVALENT
    BURGESS, PH
    BARTLETT, DT
    MCCLURE, DR
    [J]. RADIATION PROTECTION DOSIMETRY, 1989, 28 (1-2) : 83 - 87
  • [23] Theoretical analysis and experimental evaluation of a CsI(Tl) based electronic portal imaging system
    Sawant, A
    Zeman, H
    Samant, S
    Lovhoiden, G
    Weinberg, B
    DiBianca, F
    [J]. MEDICAL PHYSICS, 2002, 29 (06) : 1042 - 1053
  • [24] Measurement of the radiation dose distribution in EAST hall based on thermoluminescence dosimeter
    Zhou, Mengjie
    Hu, Liqun
    Huang, Liangsheng
    Zhong, Guoqiang
    Li, Kai
    Hong, Bing
    Xiao, Min
    Zhang, Ruixue
    [J]. FUSION ENGINEERING AND DESIGN, 2020, 160
  • [25] Computer controlled ambient dose equivalent meter based on a recombination chamber
    Zielczynski, M.
    Golnik, N.
    Rusinowski, Z.
    [J]. Nuclear Instruments & Methods in Physics Research, 370 (2-3):
  • [26] A computer controlled ambient dose equivalent meter based on a recombination chamber
    Zielczynski, M
    Golnik, N
    Rusinowski, Z
    [J]. NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1996, 370 (2-3): : 563 - 567
  • [27] Measurement of neutron ambient dose equivalent in passive carbon-ion and proton radiotherapies
    Yonai, Shunsuke
    Matsufuji, Naruhiro
    Kanai, Tatsuaki
    Matsui, Yuki
    Matsushita, Kaoru
    Yamashita, Haruo
    Numano, Masumi
    Sakae, Takeji
    Terunuma, Toshiyuki
    Nishio, Teiji
    Kohno, Ryosuke
    Akagi, Takashi
    [J]. MEDICAL PHYSICS, 2008, 35 (11) : 4782 - 4792
  • [28] ASSESSMENT OF TERRESTRIAL RADIATION BY DIRECT MEASUREMENT OF AMBIENT DOSE EQUIVALENT RATE OF BACKGROUND RADIATION
    Kardan, Mohammad Reza
    Sadeghi, Nahid
    Fathabadi, Nasrin
    Attarilar, Ali
    [J]. RADIATION PROTECTION DOSIMETRY, 2019, 184 (02) : 189 - 197
  • [29] Development of a secondary standard ionization chamber for environmental level ambient dose equivalent measurement
    Xu, Yang
    Gao, Fei
    Ni, Ning
    Wang, Feifei
    Liu, Yuntao
    Lin, Min
    [J]. APPLIED RADIATION AND ISOTOPES, 2022, 180
  • [30] Simulation studies on a prototype ionisation chamber for measurement of personal dose equivalent, Hp(10)
    Cardoso, J.
    Carvalho, A. F.
    Oliveira, C.
    [J]. RADIATION PROTECTION DOSIMETRY, 2007, 125 (1-4) : 175 - 179