Eight-Channel Monopole Array Using ICE Decoupling for Human Head MR Imaging at 7 T

被引:8
|
作者
Yan, Xinqiang [1 ,2 ,3 ]
Wei, Long [2 ,3 ]
Chu, Suoda [1 ]
Xue, Rong [1 ,4 ]
Zhang, Xiaoliang [5 ,6 ]
机构
[1] Chinese Acad Sci, State Key Lab Brain & Cognit Sci, Inst Biophys, Beijing MRI Ctr Brain Res, Beijing 100101, Peoples R China
[2] Chinese Acad Sci, Inst High Energy Phys, Key Lab Nucl Radiat & Nucl Energy Technol, Beijing 100049, Peoples R China
[3] Beijing Engn Res Ctr Radiog Tech & Equipment, 19B Yuquan Rd, Beijing 100049, Peoples R China
[4] Beijing Inst Brain Disorders, Beijing 100053, Peoples R China
[5] Univ Calif San Francisco, Dept Radiol & Biomed Imaging, Byers Hall,Room 102,1700 4th ST, San Francisco, CA USA
[6] UCSF UC Berkeley Joint Grad Grp Bioengn, San Francisco, CA 94158 USA
基金
中国国家自然科学基金; 美国国家卫生研究院;
关键词
SURFACE COIL ARRAY; NMR PHASED-ARRAY; HUMAN BRAIN; FIELD MRI; IN-VIVO; DESIGN; TESLA; SENSITIVITY; ANTENNA; SPECTROSCOPY;
D O I
10.1007/s00723-016-0775-7
中图分类号
O64 [物理化学(理论化学)、化学物理学]; O56 [分子物理学、原子物理学];
学科分类号
070203 ; 070304 ; 081704 ; 1406 ;
摘要
Due to the unique structure of radiative coil elements, traditional decoupling methods face technical challenges in reducing the electromagnetic coupling of the radiative arrays. In this study, we aim to investigate the possibility of using the recently introduced induced current elimination (ICE) decoupling technique for cylindrical shaped radiative coil array designs. To evaluate the method, an eight-channel transmit/receive monopole array with the ICE decoupling, suitable for human head imaging at 7 T, was built and comparatively investigated. In vivo human head images were acquired and geometry factor maps were measured and calculated to evaluate the performance of the ICE-decoupled monopole array. Compared with the monopole array without decoupling methods, the ICE-decoupled monopole array had a higher signal-to-noise ratio and demonstrated improved parallel imaging ability. The experimental results indicate that the ICE decoupling method is a promising solution to addressing the coupling issue of radiative array at ultrahigh fields.
引用
收藏
页码:527 / 538
页数:12
相关论文
共 50 条
  • [31] Design and comparison of two eight-channel transmit/receive radiofrequency arrays for in vivo rodent imaging on a 7 T human whole-body MRI system
    Orzada, Stephan
    Maderwald, Stefan
    Goericke, Sophia L.
    Parohl, Nina
    Ladd, Susanne C.
    Ladd, Mark E.
    Quick, Harald H.
    MEDICAL PHYSICS, 2010, 37 (05) : 2225 - 2232
  • [32] Open design eight-channel transmit/receive coil for high-resolution and real-time ankle imaging at 7 T
    Orzada, Stephan
    Bitz, Andreas K.
    Schaefer, Lena C.
    Ladd, Susanne C.
    Ladd, Mark E.
    Maderwald, Stefan
    MEDICAL PHYSICS, 2011, 38 (03) : 1162 - 1167
  • [33] Monopole antenna array design for 3 T and 7 T magnetic resonance imaging
    Kausar, A. S. M. Zahid
    Reutens, David C.
    Weber, Ewald
    Vegh, Viktor
    PLOS ONE, 2019, 14 (04):
  • [34] The eight-channel Tx dipole and 20-channel Rx loop coil array for MRI of the cervical spinal cord at 7 Tesla
    Lopez-Rios, Nibardo
    Gilbert, Kyle M. M.
    Papp, Daniel
    Cereza, Gaspard
    Foias, Alexandru
    Rangaprakash, Deshpande
    May, Markus W. W.
    Guerin, Bastien
    Wald, Lawrence L. L.
    Keil, Boris
    Stockmann, Jason P. P.
    Barry, Robert L. L.
    Cohen-Adad, Julien
    NMR IN BIOMEDICINE, 2023, 36 (11)
  • [35] An eight-channel T/R head coil for parallel transmit MRI at 3T using ultra-low output impedance amplifiers
    Moody, Katherine Lynn
    Hollingsworth, Neal A.
    Zhao, Feng
    Nielsen, Jon-Fredrik
    Noll, Douglas C.
    Wright, Steven M.
    McDougall, Mary Preston
    JOURNAL OF MAGNETIC RESONANCE, 2014, 246 : 62 - 68
  • [36] Sodium imaging of human brain at 7 T with 15-channel array coil
    Qian, Yongxian
    Zhao, Tiejun
    Wiggins, Graham C.
    Wald, Lawrence L.
    Zheng, Hai
    Weimer, Jonathan
    Boada, Fernando E.
    MAGNETIC RESONANCE IN MEDICINE, 2012, 68 (06) : 1808 - 1814
  • [37] An evaluation of the coax monopole antenna as a transmit array element for head imaging at 14 T
    Bude, Lyanne M. I.
    Vat, Koen
    Voogt, Ingmar J.
    Zivkovic, Irena
    Raaijmakers, Alexander J. E.
    MAGNETIC RESONANCE IN MEDICINE, 2025, 93 (06) : 2667 - 2679
  • [38] 3D 1H MRSI of brain tumors at 3.0 tesla using an eight-channel phased-array head coil
    Osorio, Joseph A.
    Ozturk-Isik, Esin
    Xu, Duan
    Cha, Soonmee
    Chang, Susan
    Berger, Mitchel S.
    Vigneron, Daniel B.
    Nelson, Sarah J.
    JOURNAL OF MAGNETIC RESONANCE IMAGING, 2007, 26 (01) : 23 - 30
  • [39] Design and Test of Magnetic Wall Decoupling for Dipole Transmit/Receive Array for MR Imaging at the Ultrahigh Field of 7T
    Xinqiang Yan
    Xiaoliang Zhang
    Long Wei
    Rong Xue
    Applied Magnetic Resonance, 2015, 46 : 59 - 66
  • [40] Design and Test of Magnetic Wall Decoupling for Dipole Transmit/Receive Array for MR Imaging at the Ultrahigh Field of 7T
    Yan, Xinqiang
    Zhang, Xiaoliang
    Wei, Long
    Xue, Rong
    APPLIED MAGNETIC RESONANCE, 2015, 46 (01) : 59 - 66