Sodium imaging of human brain at 7 T with 15-channel array coil

被引:35
|
作者
Qian, Yongxian [1 ,2 ]
Zhao, Tiejun [3 ]
Wiggins, Graham C. [4 ]
Wald, Lawrence L. [5 ]
Zheng, Hai [2 ]
Weimer, Jonathan [2 ]
Boada, Fernando E. [1 ,2 ]
机构
[1] Univ Pittsburgh, MR Res Ctr, Dept Radiol, Pittsburgh, PA 15213 USA
[2] Univ Pittsburgh, Dept Bioengn, Pittsburgh, PA USA
[3] Siemens Med Solut USA, Pittsburgh, PA USA
[4] NYU, Dept Radiol, Langone Med Ctr, New York, NY 10016 USA
[5] Harvard Univ, Massachusetts Gen Hosp, Sch Med, Athinoula A Martinos Ctr Biomed Imaging, Boston, MA USA
关键词
sodium MRI; whole-body 7 T MRI; phased array coil; signal-to-noise ratio; PHASED-ARRAY; TUMORS;
D O I
10.1002/mrm.24192
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Signal-to-noise ratio (SNR) is a major challenge to sodium magnetic resonance imaging. Phased array coils have been shown significantly improving SNR in proton imaging over volume coils. This study investigates SNR advantage of a 15-channel array head coil (birdcage volume coil for transmit/receive and 15-channel array insert for receive-only) in sodium imaging at 7 T. Phantoms and healthy human brains were scanned on a whole-body 7 T magnetic resonance imaging scanner using a customer-developed pulse sequence with the twisted projection imaging trajectory. Noise-only images were acquired with blanked radiofrequency excitations for noise measurement on a pixel basis. SNR was calculated on the root of sum-of-squares images. When compared with the volume coil, the 15-channel array produced SNR more than doubled at the periphery and slightly increased at the center of the phantoms and human brains. Decorrelation of noise across channels of the array coil extended the SNR-doubled region into deep area of the brain. The spatial modulation of element sensitivities on the sum-of-squares combined image was removed by performing self-calibrated sensitivity encoding parallel image reconstruction and uniform image intensity across entire field of view was attained. The 15-channel array coil is an efficient tool to substantially improve SNR in sodium imaging on human brain. Magn Reson Med, 2012. (c) 2012 Wiley Periodicals, Inc.
引用
收藏
页码:1808 / 1814
页数:7
相关论文
共 50 条
  • [1] Eight-channel phased array coil and detunable TEM volume coil for 7 T brain imaging
    Wiggins, GC
    Potthast, A
    Triantafyllou, C
    Wiggins, CJ
    Wald, LL
    MAGNETIC RESONANCE IN MEDICINE, 2005, 54 (01) : 235 - 240
  • [2] A radially interleaved sodium and proton coil array for brain MRI at 7 T
    Wang, Bili
    Zhang, Bei
    Yu, Zidan
    Ianniello, Carlotta
    Lakshmanan, Karthik
    Paska, Jan
    Madelin, Guillaume
    Cloos, Martijn
    Brown, Ryan
    NMR IN BIOMEDICINE, 2021, 34 (12)
  • [3] A 16-channel AC/DC array coil for anesthetized monkey whole-brain imaging at 7T
    Gao, Yang
    Mareyam, Azma
    Sun, Yi
    Witzel, Thomas
    Arango, Nicolas
    Kuang, Irene
    White, Jacob
    Roe, Anna Wang
    Wald, Lawrence
    Stockmann, Jason
    Zhang, Xiaotong
    NEUROIMAGE, 2020, 207
  • [4] An Eight-Channel Phased Array RF Coil for Spine MR Imaging at 7 T
    Kraff, Oliver
    Bitz, Andreas K.
    Kruszona, Stefan
    Orzada, Stephan
    Schaefer, Lena C.
    Theysohn, Jens M.
    Maderwald, Stefan
    Ladd, Mark E.
    Quick, Harald H.
    INVESTIGATIVE RADIOLOGY, 2009, 44 (11) : 734 - 740
  • [5] A 128-channel receive array for cortical brain imaging at 7 T
    Gruber, Bernhard
    Stockmann, Jason P. P.
    Mareyam, Azma
    Keil, Boris
    Bilgic, Berkin
    Chang, Yulin
    Kazemivalipour, Ehsan
    Beckett, Alexander J. S.
    Vu, An T. T.
    Feinberg, David A. A.
    Wald, Lawrence L. L.
    MAGNETIC RESONANCE IN MEDICINE, 2023, 90 (06) : 2592 - 2607
  • [6] Sodium imaging of the heart at 7T: design, evaluation and application of a four-channel transmit/receive surface coil array
    A Graessl
    A Ruehle
    W Renz
    L Winter
    H Pfeiffer
    J Ruff
    J Rieger
    T Niendorf
    Journal of Cardiovascular Magnetic Resonance, 15 (Suppl 1)
  • [7] Hybrid Monopole/Loop Coil Array for Human Head MR Imaging at 7 T
    Xinqiang Yan
    Long Wei
    Rong Xue
    Xiaoliang Zhang
    Applied Magnetic Resonance, 2015, 46 : 541 - 550
  • [8] Hybrid Monopole/Loop Coil Array for Human Head MR Imaging at 7 T
    Yan, Xinqiang
    Wei, Long
    Xue, Rong
    Zhang, Xiaoliang
    APPLIED MAGNETIC RESONANCE, 2015, 46 (05) : 541 - 550
  • [9] Transceive surface coil array for magnetic resonance imaging of the human brain at 4 T
    Pinkerton, RG
    Barberi, EA
    Menon, RS
    MAGNETIC RESONANCE IN MEDICINE, 2005, 54 (02) : 499 - 503
  • [10] Quantitative 7T sodium magnetic resonance imaging of the human brain using a 32-channel phased-array head coil: Application to patients with secondary progressive multiple sclerosis
    Wilferth, Tobias
    Mennecke, Angelika
    Gast, Lena, V
    Lachner, Sebastian
    Mueller, Max
    Rothhammer, Veit
    Huhn, Konstantin
    Uder, Michael
    Doerfler, Arnd
    Nagel, Armin M.
    Schmidt, Manuel
    NMR IN BIOMEDICINE, 2022, 35 (12)