Sodium imaging of human brain at 7 T with 15-channel array coil

被引:35
|
作者
Qian, Yongxian [1 ,2 ]
Zhao, Tiejun [3 ]
Wiggins, Graham C. [4 ]
Wald, Lawrence L. [5 ]
Zheng, Hai [2 ]
Weimer, Jonathan [2 ]
Boada, Fernando E. [1 ,2 ]
机构
[1] Univ Pittsburgh, MR Res Ctr, Dept Radiol, Pittsburgh, PA 15213 USA
[2] Univ Pittsburgh, Dept Bioengn, Pittsburgh, PA USA
[3] Siemens Med Solut USA, Pittsburgh, PA USA
[4] NYU, Dept Radiol, Langone Med Ctr, New York, NY 10016 USA
[5] Harvard Univ, Massachusetts Gen Hosp, Sch Med, Athinoula A Martinos Ctr Biomed Imaging, Boston, MA USA
关键词
sodium MRI; whole-body 7 T MRI; phased array coil; signal-to-noise ratio; PHASED-ARRAY; TUMORS;
D O I
10.1002/mrm.24192
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Signal-to-noise ratio (SNR) is a major challenge to sodium magnetic resonance imaging. Phased array coils have been shown significantly improving SNR in proton imaging over volume coils. This study investigates SNR advantage of a 15-channel array head coil (birdcage volume coil for transmit/receive and 15-channel array insert for receive-only) in sodium imaging at 7 T. Phantoms and healthy human brains were scanned on a whole-body 7 T magnetic resonance imaging scanner using a customer-developed pulse sequence with the twisted projection imaging trajectory. Noise-only images were acquired with blanked radiofrequency excitations for noise measurement on a pixel basis. SNR was calculated on the root of sum-of-squares images. When compared with the volume coil, the 15-channel array produced SNR more than doubled at the periphery and slightly increased at the center of the phantoms and human brains. Decorrelation of noise across channels of the array coil extended the SNR-doubled region into deep area of the brain. The spatial modulation of element sensitivities on the sum-of-squares combined image was removed by performing self-calibrated sensitivity encoding parallel image reconstruction and uniform image intensity across entire field of view was attained. The 15-channel array coil is an efficient tool to substantially improve SNR in sodium imaging on human brain. Magn Reson Med, 2012. (c) 2012 Wiley Periodicals, Inc.
引用
收藏
页码:1808 / 1814
页数:7
相关论文
共 50 条
  • [31] An eight-channel sodium/proton coil for brain MRI at 3T
    Lakshmanan, Karthik
    Brown, Ryan
    Madelin, Guillaume
    Qian, Yongxian
    Boada, Fernando
    Wiggins, Graham C.
    NMR IN BIOMEDICINE, 2018, 31 (02)
  • [32] A radiofrequency coil configuration for imaging the human vertebral column at 7 T
    Vossen, M.
    Teeuwisse, W.
    Reijnierse, M.
    Collins, C. M.
    Smith, N. B.
    Webb, A. G.
    JOURNAL OF MAGNETIC RESONANCE, 2011, 208 (02) : 291 - 297
  • [33] Complex B1 mapping and electrical properties imaging of the human brain using a 16-channel transceiver coil at 7T
    Zhang, Xiaotong
    Van de Moortele, Pierre-Francois
    Schmitter, Sebastian
    He, Bin
    MAGNETIC RESONANCE IN MEDICINE, 2013, 69 (05) : 1285 - 1296
  • [34] Dynamic multi-coil shimming of the human brain at 7 T
    Juchem, Christoph
    Nixon, Terence W.
    McIntyre, Scott
    Boer, Vincent O.
    Rothman, Douglas L.
    de Graaf, Robin A.
    JOURNAL OF MAGNETIC RESONANCE, 2011, 212 (02) : 280 - 288
  • [35] Design of 8 channel insertional pTx array coil for 3T body imaging
    Kim, Young Beom
    Ryu, Yeunchul
    Transactions of the Korean Institute of Electrical Engineers, 2014, 63 (04): : 546 - 550
  • [36] Design and construction of an 8-channel transceiver coil array for rat imaging at 9.4 T
    Du, Feng
    Li, Nan
    Yang, Xing
    Zhang, Baogui
    Zhang, Xiaoliang
    Li, Ye
    JOURNAL OF MAGNETIC RESONANCE, 2023, 351
  • [37] Double-row dipole/loop combined array for human whole brain imaging at 7 T
    Avdievich, Nikolai, I
    Nikulin, Anton, V
    Ruhm, Loreen
    Magill, Arthur W.
    Henning, Anke
    Scheffler, Klaus
    NMR IN BIOMEDICINE, 2022, 35 (10)
  • [38] Folded-end dipole transceiver array for human whole-brain imaging at 7 T
    Avdievich, Nikolai I.
    Solomakha, Georgiy
    Ruhm, Loreen
    Nikulin, Anton V.
    Magill, Arthur W.
    Scheffler, Klaus
    NMR IN BIOMEDICINE, 2021, 34 (08)
  • [39] Eight-Channel Monopole Array Using ICE Decoupling for Human Head MR Imaging at 7 T
    Yan, Xinqiang
    Wei, Long
    Chu, Suoda
    Xue, Rong
    Zhang, Xiaoliang
    APPLIED MAGNETIC RESONANCE, 2016, 47 (05) : 527 - 538
  • [40] Eight-Channel Monopole Array Using ICE Decoupling for Human Head MR Imaging at 7 T
    Xinqiang Yan
    Long Wei
    Suoda Chu
    Rong Xue
    Xiaoliang Zhang
    Applied Magnetic Resonance, 2016, 47 : 527 - 538