Eight-Channel Monopole Array Using ICE Decoupling for Human Head MR Imaging at 7 T

被引:8
|
作者
Yan, Xinqiang [1 ,2 ,3 ]
Wei, Long [2 ,3 ]
Chu, Suoda [1 ]
Xue, Rong [1 ,4 ]
Zhang, Xiaoliang [5 ,6 ]
机构
[1] Chinese Acad Sci, State Key Lab Brain & Cognit Sci, Inst Biophys, Beijing MRI Ctr Brain Res, Beijing 100101, Peoples R China
[2] Chinese Acad Sci, Inst High Energy Phys, Key Lab Nucl Radiat & Nucl Energy Technol, Beijing 100049, Peoples R China
[3] Beijing Engn Res Ctr Radiog Tech & Equipment, 19B Yuquan Rd, Beijing 100049, Peoples R China
[4] Beijing Inst Brain Disorders, Beijing 100053, Peoples R China
[5] Univ Calif San Francisco, Dept Radiol & Biomed Imaging, Byers Hall,Room 102,1700 4th ST, San Francisco, CA USA
[6] UCSF UC Berkeley Joint Grad Grp Bioengn, San Francisco, CA 94158 USA
基金
中国国家自然科学基金; 美国国家卫生研究院;
关键词
SURFACE COIL ARRAY; NMR PHASED-ARRAY; HUMAN BRAIN; FIELD MRI; IN-VIVO; DESIGN; TESLA; SENSITIVITY; ANTENNA; SPECTROSCOPY;
D O I
10.1007/s00723-016-0775-7
中图分类号
O64 [物理化学(理论化学)、化学物理学]; O56 [分子物理学、原子物理学];
学科分类号
070203 ; 070304 ; 081704 ; 1406 ;
摘要
Due to the unique structure of radiative coil elements, traditional decoupling methods face technical challenges in reducing the electromagnetic coupling of the radiative arrays. In this study, we aim to investigate the possibility of using the recently introduced induced current elimination (ICE) decoupling technique for cylindrical shaped radiative coil array designs. To evaluate the method, an eight-channel transmit/receive monopole array with the ICE decoupling, suitable for human head imaging at 7 T, was built and comparatively investigated. In vivo human head images were acquired and geometry factor maps were measured and calculated to evaluate the performance of the ICE-decoupled monopole array. Compared with the monopole array without decoupling methods, the ICE-decoupled monopole array had a higher signal-to-noise ratio and demonstrated improved parallel imaging ability. The experimental results indicate that the ICE decoupling method is a promising solution to addressing the coupling issue of radiative array at ultrahigh fields.
引用
收藏
页码:527 / 538
页数:12
相关论文
共 50 条
  • [41] A 32-element loop/dipole hybrid array for human head imaging at 7 T
    Avdievich, Nikolai I.
    Nikulin, Anton V.
    Ruhm, Loreen
    Magill, Arthur W.
    Glang, Felix
    Henning, Anke
    Scheffler, Klaus
    MAGNETIC RESONANCE IN MEDICINE, 2022, 88 (04) : 1912 - 1926
  • [42] MR imaging of the human hand and wrist at 7 T
    Björn Behr
    Jörg Stadler
    Henrik J. Michaely
    Hans-Georg Damert
    Wolfgang Schneider
    Skeletal Radiology, 2009, 38 : 911 - 917
  • [43] MR imaging of the human hand and wrist at 7 T
    Behr, Bjoern
    Stadler, Joerg
    Michaely, Henrik J.
    Damert, Hans-Georg
    Schneider, Wolfgang
    SKELETAL RADIOLOGY, 2009, 38 (09) : 911 - 917
  • [44] A 16-channel Transceiver Loop plus Dipole Antennas Head Array for Human Head Imaging at 10.5T
    Woo, Myung Kyun
    Lagore, Russell L.
    DelaBarre, Lance
    Lee, Byeong-Yeul
    Eryaman, Yigitcan
    Radder, Jerahmie
    Erturk, Arcan
    Metzger, Gregory
    van de Moortele, Pierre-Francois
    Ugurbil, Kamil
    Adriany, Gregor
    2017 INTERNATIONAL CONFERENCE ON ELECTROMAGNETICS IN ADVANCED APPLICATIONS (ICEAA), 2017, : 1649 - 1652
  • [45] Spatial and temporal variations of flip-angle distributions in the human brain using an eight-channel parallel transmission system at 7T: comparison of three radiofrequency excitation methods
    Tsuyoshi Matsuda
    Ikuko Uwano
    Yuji Iwadate
    Kunihiro Yoshioka
    Makoto Sasaki
    Radiological Physics and Technology, 2021, 14 : 161 - 166
  • [46] Simultaneous whole-brain and cervical spine imaging at 7 T using a neurovascular head and neck coil with 8-channel transceiver array and 56-channel receiver array
    Baskaran, Divya
    Ding, Belinda
    Chu, Son
    Mcelhinney, Paul
    Allwood-Spiers, Sarah
    Williams, Sydney N.
    Muir, Keith
    Fullerton, Natasha Eileen
    Porter, David Andrew
    Gunamony, Shajan
    MAGNETIC RESONANCE IN MEDICINE, 2025,
  • [47] Spatial and temporal variations of flip-angle distributions in the human brain using an eight-channel parallel transmission system at 7T: comparison of three radiofrequency excitation methods
    Matsuda, Tsuyoshi
    Uwano, Ikuko
    Iwadate, Yuji
    Yoshioka, Kunihiro
    Sasaki, Makoto
    RADIOLOGICAL PHYSICS AND TECHNOLOGY, 2021, 14 (02) : 161 - 166
  • [48] Field Distribution and Coupling Investigation of an Eight-Channel RF Coil Consisting of Different Dipole Coil Elements for 7 T MRI
    Chen, Zhichao
    Solbach, Klaus
    Erni, Daniel
    Rennings, Andreas
    IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 2017, 64 (06) : 1297 - 1304
  • [49] CHARACTERIZATION OF MR SPECTROSCOPIC IMAGING OF THE HUMAN HEAD AND LIMB AT 2.0 T
    TROPP, JS
    SUGIURA, S
    DERBY, KA
    SUZUKI, Y
    HAWRYSZKO, C
    YAMAGATA, H
    KLEIN, JE
    ORTENDAHL, DA
    KAUFMAN, L
    ACOSTA, GF
    RADIOLOGY, 1988, 169 (01) : 207 - 212
  • [50] Decoupling of folded-end dipole antenna elements of a 9.4 T human head array using an RF shield
    Avdievich, Nikolai, I
    Solomakha, Georgiy
    Ruhm, Loreen
    Scheffler, Klaus
    Henning, Anke
    NMR IN BIOMEDICINE, 2020, 33 (09)