Optimization of MAGIC gel formulation for three-dimensional radiation therapy dosimetry

被引:18
|
作者
Luci, J. J.
Whitney, H. M.
Gore, J. C.
机构
[1] Vanderbilt Univ, Inst Imaging Sci, Nashville, TN 37232 USA
[2] Vanderbilt Univ, Dept Radiol & Radiol Sci, Nashville, TN 37232 USA
[3] Vanderbilt Univ, Dept Phys & Astron, Nashville, TN 37232 USA
来源
PHYSICS IN MEDICINE AND BIOLOGY | 2007年 / 52卷 / 10期
关键词
D O I
10.1088/0031-9155/52/10/N03
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Polymer gel dosimetry aims to provide three-dimensional images of radiation therapy dose distributions in irradiated aqueous gels. The first gels required manufacture in an oxygen-free environment, but later the MAGIC formulation was introduced, which could be made in normal atmospheric conditions. Here we report our studies of the effects of variations in the composition of the MAGIC gel performed in order to optimize its performance over the useful dose range of 0 to 20 Gy. A new formulation (termed 'MAGIC-2') is comprised of 87% water, 4% methacrylic acid, 9% gelatin, 17.38 x 10(-6) M Cu2+ and a molar ratio of ascorbic acid to [Cu2+] of 1000:1. MAGIC-2 has a dose-response slope-to-intercept ratio that is 78% greater than the original formulation and other more favorable properties.
引用
收藏
页码:N241 / N248
页数:8
相关论文
共 50 条
  • [41] Optimization of the shape of a three-dimensional body for radiation heat flux
    Arguchintseva, MA
    Pilyugin, NN
    HIGH TEMPERATURE, 2002, 40 (04) : 557 - 570
  • [42] Optimization of the Shape of a Three-Dimensional Body for Radiation Heat Flux
    M. A. Arguchintseva
    N. N. Pilyugin
    High Temperature, 2002, 40 : 557 - 570
  • [43] Registration of serial SPECT/CT images for three-dimensional dosimetry in radionuclide therapy
    Sjogreen-Gleisner, K.
    Rueckert, D.
    Ljungberg, M.
    PHYSICS IN MEDICINE AND BIOLOGY, 2009, 54 (20): : 6181 - 6200
  • [44] Three dimensional polymer gel dosimetry: State of the art
    De Deene, Y.
    RADIOTHERAPY AND ONCOLOGY, 2007, 84 : S71 - S71
  • [45] Routine three-dimensional dosimetry of hadron beams
    Cirio, R
    Dellacasa, G
    Donetti, M
    Isoardi, P
    Marchetto, F
    Peroni, C
    Ruspa, M
    ADVANCES IN HADRONTHERAPY, 1997, 1144 : 290 - 297
  • [46] MR imaging of superheated drop dosimeters for three-dimensional radiation dosimetry of a brachytherapy source
    Lamba, MA
    Holland, SK
    Elson, HR
    DErrico, F
    Nath, R
    RADIOLOGY, 1997, 205 : 1244 - 1244
  • [47] Three-dimensional dosimetry in brachytherapy: A MAGAT study
    Lin, Min-Hsing
    Huang, Tzung-Chi
    Kao, Ming-Jen
    Wu, Jay
    Chen, Chia-Lin
    Wu, Tung-Hsin
    APPLIED RADIATION AND ISOTOPES, 2009, 67 (7-8) : 1432 - 1437
  • [48] Three-dimensional conformal radiation therapy for refractory laryngeal granuloma
    Wang, Jianhua
    Shi, Mei
    Xia, Yuesheng
    Luo, Shanquan
    Fu, Xuehai
    Xiao, Feng
    Li, Jianping
    Deng, Zhihong
    Long, Xiaoli
    TUMORI JOURNAL, 2011, 97 (03): : 345 - 349
  • [49] Measurement of the three-dimensional distribution of radiation dose in grid therapy
    Trapp, JV
    Warrington, AP
    Partridge, M
    Philps, A
    Glees, J
    Tait, D
    Ahmed, R
    Leach, MO
    Webb, S
    PHYSICS IN MEDICINE AND BIOLOGY, 2004, 49 (19): : N317 - N323
  • [50] Three-dimensional microtissues as an in vitro model for personalized radiation therapy
    Qiu, Yuting
    Ning, Dandan
    Zhang, Peipei
    Curly, Stephanie
    Qiao, Yong
    Ma, Liyuan
    Su, Ming
    ANALYST, 2017, 142 (19) : 3605 - 3612