Optimization of MAGIC gel formulation for three-dimensional radiation therapy dosimetry

被引:18
|
作者
Luci, J. J.
Whitney, H. M.
Gore, J. C.
机构
[1] Vanderbilt Univ, Inst Imaging Sci, Nashville, TN 37232 USA
[2] Vanderbilt Univ, Dept Radiol & Radiol Sci, Nashville, TN 37232 USA
[3] Vanderbilt Univ, Dept Phys & Astron, Nashville, TN 37232 USA
来源
PHYSICS IN MEDICINE AND BIOLOGY | 2007年 / 52卷 / 10期
关键词
D O I
10.1088/0031-9155/52/10/N03
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Polymer gel dosimetry aims to provide three-dimensional images of radiation therapy dose distributions in irradiated aqueous gels. The first gels required manufacture in an oxygen-free environment, but later the MAGIC formulation was introduced, which could be made in normal atmospheric conditions. Here we report our studies of the effects of variations in the composition of the MAGIC gel performed in order to optimize its performance over the useful dose range of 0 to 20 Gy. A new formulation (termed 'MAGIC-2') is comprised of 87% water, 4% methacrylic acid, 9% gelatin, 17.38 x 10(-6) M Cu2+ and a molar ratio of ascorbic acid to [Cu2+] of 1000:1. MAGIC-2 has a dose-response slope-to-intercept ratio that is 78% greater than the original formulation and other more favorable properties.
引用
收藏
页码:N241 / N248
页数:8
相关论文
共 50 条
  • [31] Three-dimensional quality assurance of IMRT prostate plans using gel dosimetry
    Silveira, M. A.
    Pavoni, J. F.
    Baffa, O.
    PHYSICA MEDICA-EUROPEAN JOURNAL OF MEDICAL PHYSICS, 2017, 34 : 1 - 6
  • [32] The study of the dosimetric properties of 'RadGell, a new dosimeter for three-dimensional gel dosimetry
    Guo, P
    Appleby, A
    Oldham, M
    MEDICAL PHYSICS, 2005, 32 (06) : 2009 - 2009
  • [33] Three-Dimensional Gel Dosimetry for Dose Volume Histogram Verification in Stereotactic Radiosurgery
    Semnicka, J.
    Novotny, J., Jr.
    Spevacek, V.
    Garcic, J.
    Steiner, M.
    Judas, L.
    RADIOSURGERY, VOL 7, 2010, 7 : 44 - 55
  • [34] Application of three-dimensional dosimetry to multiple treatments of radionuclide therapy.
    Flux, GD
    Guy, ML
    Papavasileiou, P
    Chittenden, S
    Pomeroy, KM
    Meller, S
    Vini, L
    Flower, M
    JOURNAL OF NUCLEAR MEDICINE, 2001, 42 (05) : 22P - 22P
  • [35] Three-dimensional conformal radiation therapy in bronchogenic carcinoma
    Emami, B
    SEMINARS IN RADIATION ONCOLOGY, 1996, 6 (02) : 92 - 97
  • [36] Radiation injury of the lung after three-dimensional conformal radiation therapy
    Koenig, TR
    Munden, RF
    Erasmus, JJ
    Sabloff, BS
    Gladish, GW
    Komaki, R
    Stevens, CW
    AMERICAN JOURNAL OF ROENTGENOLOGY, 2002, 178 (06) : 1383 - 1388
  • [37] Three-dimensional echocardiography for optimization of cardiac resynchronization therapy
    Ballo, Piercarlo
    Motto, Andrea
    Mondillo, Sergio
    Galderisi, Maurizio
    EUROPEAN HEART JOURNAL, 2009, 30 (04) : 505 - 505
  • [38] THREE-DIMENSIONAL OPTIMIZATION METHOD FOR THE INTERSTITIONAL AFTERLOADING THERAPY
    SCHULZ, U
    BUSCH, M
    STRAHLENTHERAPIE, 1979, 155 (06) : 400 - 402
  • [39] Three-dimensional shape optimization of hip prostheses using a multicriteria formulation
    Ruben, Rui B.
    Folgado, Joao
    Fernandes, Paulo R.
    STRUCTURAL AND MULTIDISCIPLINARY OPTIMIZATION, 2007, 34 (03) : 261 - 275
  • [40] Three-dimensional shape optimization of hip prostheses using a multicriteria formulation
    Rui B. Ruben
    João Folgado
    Paulo R. Fernandes
    Structural and Multidisciplinary Optimization, 2007, 34 : 261 - 275