Design of a radon measuring device based on the diffusion principle using LR 115 detector

被引:13
|
作者
Djeffal, S
Lounis, Z
Allab, M
机构
[1] Ctr Radioprotect & Surete, Lab Dosimetrie, Alger, Algeria
[2] Univ Sci & Technol, Inst Phys, Alger, Algeria
关键词
radon measurement; LR; 115; II; diffusion chamber; filter membrane;
D O I
10.1016/S1350-4487(97)00154-6
中图分类号
TL [原子能技术]; O571 [原子核物理学];
学科分类号
0827 ; 082701 ;
摘要
This paper reports the theoretical studies undertaken to determine the optimum dimensions of the diffusion chamber and the membrane thickness which is sufficient to prevent the thoron gas diffusion and permit the rapid establishment of equilibrium between radon concentration outside and inside the chamber volume.
引用
收藏
页码:629 / 632
页数:4
相关论文
共 50 条
  • [21] RADON SURVEY IN ALGERIAN DWELLINGS USING LR-115 TRACK FILM
    DJEFFAL, S
    CHEROUATI, DE
    DURRANI, SA
    NUCLEAR TRACKS AND RADIATION MEASUREMENTS, 1988, 15 (1-4): : 587 - 589
  • [22] Theoretical and experimental study of the LR-115 detector response in a non-commercial radon monitor
    Perez, B.
    Lopez, M. E.
    Palacios, D.
    APPLIED RADIATION AND ISOTOPES, 2020, 160
  • [23] Overlapping correction suitable for an LR-115 detector located inside a diffusion chamber
    Perez, B.
    Lopez, M. E.
    Palacios, D.
    RADIATION PHYSICS AND CHEMISTRY, 2021, 184
  • [24] THE MEASUREMENT OF RADON EMANATION RATES FROM SOME ROCK SPECIMENS AND BUILDING-MATERIALS USING RADON EMANOMETRY AND LR-115 PLASTIC TRACK DETECTOR
    SINGH, S
    GHUMAN, HS
    NUCLEAR TRACKS AND RADIATION MEASUREMENTS, 1988, 15 (1-4): : 621 - 624
  • [25] Additional uses of polymeric nuclear track detectors (CR 39 and LR 115) for measuring radon emanation
    Barillon, R.
    Klein, D.
    Chambaudet, A.
    Membrey, F.
    Fromm, M.
    Nuclear Tracks and Radiation Measurements, 1991, 19 (1-4): : 291 - 296
  • [26] ANALYSIS OF SENSITIVITY OF LR-115-II IN CYLINDRICAL DIFFUSION-CHAMBERS FOR RADON CONCENTRATION DETERMINATION
    NIKEZIC, D
    BAIXERAS, C
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1995, 364 (03): : 531 - 536
  • [27] Monitoring of the unattached fraction of radon progeny by the Kodak LR-115 Type 2, nuclear track detector
    Kvasnicka, Jiri
    Zdimal, Vladimir
    Seini, Allan
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2021, 1000
  • [28] CR-39 detector compared with Kodalpha film type (LR115) in terms of radon concentration
    Dwaikat, Nidal
    Safarini, Ghassan
    El-hasan, Mousa
    Iida, Toshiyuki
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2007, 574 (02): : 289 - 291
  • [29] A semi-empirical approach to estimate the parameters determining the LR-115 detector response in radon measurements
    Rojas, Jhonny
    Palacios, Daniel
    Pereyra, Patrizia
    Perez, Bertin
    Sajo Bohus, Laszlo
    Elena Lopez, Maria
    RADIATION MEASUREMENTS, 2018, 118 : 36 - 42
  • [30] Detection efficiency of LR-115 using a new measurement device
    Sabir, A
    Marah, H
    RADON AND THORON IN THE HUMAN ENVIRONMENT, 1998, : 107 - 112