Design of a radon measuring device based on the diffusion principle using LR 115 detector

被引:13
|
作者
Djeffal, S
Lounis, Z
Allab, M
机构
[1] Ctr Radioprotect & Surete, Lab Dosimetrie, Alger, Algeria
[2] Univ Sci & Technol, Inst Phys, Alger, Algeria
关键词
radon measurement; LR; 115; II; diffusion chamber; filter membrane;
D O I
10.1016/S1350-4487(97)00154-6
中图分类号
TL [原子能技术]; O571 [原子核物理学];
学科分类号
0827 ; 082701 ;
摘要
This paper reports the theoretical studies undertaken to determine the optimum dimensions of the diffusion chamber and the membrane thickness which is sufficient to prevent the thoron gas diffusion and permit the rapid establishment of equilibrium between radon concentration outside and inside the chamber volume.
引用
收藏
页码:629 / 632
页数:4
相关论文
共 50 条
  • [41] Using the image processing in digital system to determine the nuclear parameters of LR-115 detector
    Al-jomaily, Firas Mohammed Ali
    RADIATION DETECTION TECHNOLOGY AND METHODS, 2021, 5 (02) : 255 - 263
  • [42] CONSEQUENCES OF USING HOME-MADE RADON SOURCES FOR MEASURING THE RADON DIFFUSION COEFFICIENT
    Dobrovolny, T.
    Jiranek, M.
    RADIATION PROTECTION DOSIMETRY, 2017, 177 (1-2) : 130 - 133
  • [43] Using the image processing in digital system to determine the nuclear parameters of LR-115 detector
    Firas Mohammed Ali Al-jomaily
    Radiation Detection Technology and Methods, 2021, 5 : 255 - 263
  • [44] Measuring radon concentration in air using a diffusion cloud chamber
    Cases, R.
    Ros, E.
    Zuniga, J.
    AMERICAN JOURNAL OF PHYSICS, 2011, 79 (09) : 903 - 908
  • [45] Study of the effect of temperature and water content on radon exhalation from phosphate using LR-115 detectors
    Jabbade, Meryame
    Nachab, Abdellatif
    Elouardi, Elmokhtar
    Nourreddine, Abdel-Mjid
    Errami, Ezzoura
    Benjelloun, Mohammed
    Fahad, Mohammed
    RADIATION PROTECTION DOSIMETRY, 2023, 199 (18) : 2212 - 2217
  • [46] Radon-thoron monitoring in Tatun volcanic areas of northern Taiwan using LR-115 alpha track detector technique: Pre-calibration and installation
    Kumar, Arvind
    Walia, Vivek
    Yang, Tsanyao Frank
    Chang, Hsiao-Hsien
    Lin, Shih-Jung
    Eappen, Karumpil Philips
    Arora, Baldev Raj
    ACTA GEOPHYSICA, 2013, 61 (04) : 958 - 976
  • [47] Radium concentration and radon exhalation measurements using LR-115 type II plastic track detectors
    Azam, A
    Naqvi, AH
    Srivastava, DS
    NUCLEAR GEOPHYSICS, 1995, 9 (06): : 653 - 657
  • [48] Long-term determination of airborne radon progeny concentrations using LR 115 detectors and the effects of thoron
    Choi, V. W. Y.
    Ng, C. K. M.
    Lam, R. K. K.
    Janik, M.
    Sorimachi, A.
    Kranrod, C.
    Nikezic, D.
    Tokonami, S.
    Yu, K. N.
    RADIATION PROTECTION DOSIMETRY, 2010, 141 (04) : 404 - 407
  • [49] Measurement of radon-222 in workplaces located in basements, using LR 115-type 2 detectors
    Rojas, V. Y. Guevara
    REVISTA MEXICANA DE FISICA, 2025, 71 (02)
  • [50] Radon-thoron monitoring in Tatun volcanic areas of northern Taiwan using LR-115 alpha track detector technique: Pre-calibration and installation
    Arvind Kumar
    Vivek Walia
    Tsanyao Frank Yang
    Hsiao-Hsien Chang
    Shih-Jung Lin
    Karumpil Philips Eappen
    Baldev Raj Arora
    Acta Geophysica, 2013, 61 : 958 - 976