Overlapping correction suitable for an LR-115 detector located inside a diffusion chamber

被引:0
|
作者
Perez, B. [1 ]
Lopez, M. E. [1 ]
Palacios, D. [1 ]
机构
[1] Pontificia Univ Catolica Peru, Dept Ciencias, Secc Fis, Ave Univ 1801, Lima 32, Peru
关键词
Overlapping; LR-115; Monte Carlo methods; Diffusion chamber; Radon exposure levels; V function; NUCLEAR TRACK DETECTORS; SOIL-GAS; RADON MEASUREMENTS; DWELLINGS; SCHOOLS; AREA; RISK;
D O I
10.1016/j.radphyschem.2021.109470
中图分类号
O64 [物理化学(理论化学)、化学物理学];
学科分类号
070304 ; 081704 ;
摘要
A simulation program based on Monte Carlo methods was developed to study the behaviour of the overlapping effect in the LR-115 nuclear track detectors located inside a diffusion chamber. The relation between the nonoverlapped tracks and the radon exposure level that the detector was exposed was adopted. This study focuses on very high radon concentration levels found in soil gas, uranium mines, or underground places. These anomalous levels can influence the radiological risk related to inhalation of indoor radon or the spontaneous increases in thermal neutron background. LR-115 detector exposed to anomalous levels can register a large number of latent tracks on its surface. After an etching treatment, some visible tracks can be placed covering one or more visible tracks altering the LR-115 response. In order to develop this work and be more realistic, visible tracks were simulated taking into account radon exposure level, geometry and dimensions of the diffusion chamber, dimensions of the detector, the V function, the etching process and the reading process. Results show that the overlapping effect in the LR-115 inside a cylindrical diffusion chamber exposed to very high levels can be solved with an uncertainty of 5%. The same methodology can also be applied when considering other detectors and geometry and dimensions of a diffusion chamber.
引用
收藏
页数:6
相关论文
共 50 条
  • [1] EFFICIENCY OF RADON DETECTOR LR-115
    RAMOLA, RC
    SINGH, M
    SINGH, S
    VIRK, HS
    INDIAN JOURNAL OF PURE & APPLIED PHYSICS, 1987, 25 (5-6) : 235 - 236
  • [2] RADON DOSE ASSESSMENT BY THE LR-115 DETECTOR
    PLANINIC, J
    FAJ, Z
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1990, 292 (01): : 176 - 178
  • [3] Evaluation of Efficiency Calibration Parameters of the LR-115 Radon Detector
    Mireles, F.
    Davila, J. I.
    Garcia-Betancourt, M. L.
    Pinedo, J. L.
    Lopez, H.
    HEALTH PHYSICS, 2010, 98 (05): : S63 - S68
  • [4] EFFECT OF TEMPERATURE ON ETCHING OF LR-115 PLASTIC TRACK DETECTOR
    PAUL, SN
    BOSE, SK
    NUCLEAR TRACKS AND RADIATION MEASUREMENTS, 1980, 4 (03): : 187 - 190
  • [5] ETCHING BEHAVIOUR OF LR-115 PLASTIC TRACK DETECTOR.
    Paul, S.N.
    Bose, S.K.
    Radiation effects letters, 1980, 57 (1-2): : 51 - 53
  • [6] Response of diffusion chamber with LR115 detector and electret to radon and progeny
    University of Kragujevac, Faculty of Science, R. Domanovic 12, 34000 Kragujevac, Serbia
    Radiat. Meas., 2009, 9-10 (783-786):
  • [7] Response of diffusion chamber with LR115 detector and electret to radon and progeny
    Nikezic, D.
    Krstic, D.
    Savovic, S.
    RADIATION MEASUREMENTS, 2009, 44 (9-10) : 783 - 786
  • [8] Dependence of the LR-115 radon detector calibration factor on track density
    De Cicco, F.
    Pugliese, M.
    Roca, V.
    Sabbarese, C.
    APPLIED RADIATION AND ISOTOPES, 2013, 78 : 108 - 112
  • [9] Experimental determination of LR-115 detector efficiency for exposure to alpha particles
    Marocco, D
    Bochicchio, F
    RADIATION MEASUREMENTS, 2001, 34 (1-6) : 509 - 512
  • [10] Sensitivity of LR 115 SSNTD in a diffusion chamber
    Leung, S. Y. Y.
    NikeziC, D.
    Leung, J. K. C.
    Yu, K. N.
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION B-BEAM INTERACTIONS WITH MATERIALS AND ATOMS, 2007, 263 (01): : 306 - 310