Overlapping correction suitable for an LR-115 detector located inside a diffusion chamber

被引:0
|
作者
Perez, B. [1 ]
Lopez, M. E. [1 ]
Palacios, D. [1 ]
机构
[1] Pontificia Univ Catolica Peru, Dept Ciencias, Secc Fis, Ave Univ 1801, Lima 32, Peru
关键词
Overlapping; LR-115; Monte Carlo methods; Diffusion chamber; Radon exposure levels; V function; NUCLEAR TRACK DETECTORS; SOIL-GAS; RADON MEASUREMENTS; DWELLINGS; SCHOOLS; AREA; RISK;
D O I
10.1016/j.radphyschem.2021.109470
中图分类号
O64 [物理化学(理论化学)、化学物理学];
学科分类号
070304 ; 081704 ;
摘要
A simulation program based on Monte Carlo methods was developed to study the behaviour of the overlapping effect in the LR-115 nuclear track detectors located inside a diffusion chamber. The relation between the nonoverlapped tracks and the radon exposure level that the detector was exposed was adopted. This study focuses on very high radon concentration levels found in soil gas, uranium mines, or underground places. These anomalous levels can influence the radiological risk related to inhalation of indoor radon or the spontaneous increases in thermal neutron background. LR-115 detector exposed to anomalous levels can register a large number of latent tracks on its surface. After an etching treatment, some visible tracks can be placed covering one or more visible tracks altering the LR-115 response. In order to develop this work and be more realistic, visible tracks were simulated taking into account radon exposure level, geometry and dimensions of the diffusion chamber, dimensions of the detector, the V function, the etching process and the reading process. Results show that the overlapping effect in the LR-115 inside a cylindrical diffusion chamber exposed to very high levels can be solved with an uncertainty of 5%. The same methodology can also be applied when considering other detectors and geometry and dimensions of a diffusion chamber.
引用
收藏
页数:6
相关论文
共 50 条
  • [41] A Study on the Bulk Etch Rate of LR-115 Solid State Nuclear Track Detector using Lithium Hydroxide as an Etching Solution
    Chandan, Deep
    Shikha, Deep
    Kaur, Jaswinder
    Mehta, Vimal
    INDIAN JOURNAL OF PURE & APPLIED PHYSICS, 2023, 61 (06) : 504 - 508
  • [42] Passive monitoring of the equilibrium factor inside a radon exposure chamber using bare LR 115 SSNTDs
    Leung, S. Y. Y.
    Nikezic, D.
    Yu, K. N.
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2006, 564 (01): : 319 - 323
  • [43] Surface chemical etching behavior of LR-115 type II solid state nuclear track detector: effects of UV and ultrasonic beam
    Mehta, V.
    Singh, S. P.
    Chauhan, R. P.
    Mudahar, G. S.
    OPTOELECTRONICS AND ADVANCED MATERIALS-RAPID COMMUNICATIONS, 2014, 8 (9-10): : 943 - 947
  • [44] Application of the optical spectroscopy and X-ray diffraction methods for determining the effect of irradiation of the LR-115 type 2 track detector
    Yerimbetova, D.
    Kozlovskiy, A.
    Stepanenko, V
    Zhumadilov, K.
    OPTICAL MATERIALS, 2022, 123
  • [45] Monte Carlo simulation of a simple and fast method to experimentally determine the partial sensitivity of a bare LR-115 detector using planar alpha sources
    Pereyra, Patrizia
    Palacios, Daniel
    Yoshimura, Elisabeth Mateus
    Sajo-Bohus, Laszlo
    RADIATION MEASUREMENTS, 2023, 165
  • [46] Determination of Radon Gas Concentration in the Water of Midelt Region, Morocco, Using a Nuclear Track Detector (LR-115) and Assessment of Radiological Health Risk
    Said, Khadour
    Brahim, Sedra Moulay
    Abderrahman, El boukili
    El-Taher, Atef
    POLLUTION, 2024, 10 (01): : 248 - 255
  • [47] THE MEASUREMENT OF RADON EMANATION RATES FROM SOME ROCK SPECIMENS AND BUILDING-MATERIALS USING RADON EMANOMETRY AND LR-115 PLASTIC TRACK DETECTOR
    SINGH, S
    GHUMAN, HS
    NUCLEAR TRACKS AND RADIATION MEASUREMENTS, 1988, 15 (1-4): : 621 - 624
  • [48] Derivation of V function for LR 115 SSNTD from its sensitivity to 220Rn in a diffusion chamber
    Leung, S. Y. Y.
    Nikezic, D.
    Leung, J. K. C.
    Yu, K. N.
    APPLIED RADIATION AND ISOTOPES, 2007, 65 (03) : 313 - 317
  • [49] Radon-thoron monitoring in Tatun volcanic areas of northern Taiwan using LR-115 alpha track detector technique: Pre-calibration and installation
    Kumar, Arvind
    Walia, Vivek
    Yang, Tsanyao Frank
    Chang, Hsiao-Hsien
    Lin, Shih-Jung
    Eappen, Karumpil Philips
    Arora, Baldev Raj
    ACTA GEOPHYSICA, 2013, 61 (04) : 958 - 976
  • [50] 10Boron distribution measurement in laser ablated B4C thin films using (n,α) reaction and LR-115 passive detector
    Sajo-Bohus, L.
    Simon, A.
    Csako, T.
    Nemeth, P.
    Palacios, D.
    Espinosa, G.
    Greaves, E. D.
    Szorenyi, T.
    Barros, H.
    RADIATION MEASUREMENTS, 2009, 44 (9-10) : 795 - 797