Overlapping correction suitable for an LR-115 detector located inside a diffusion chamber

被引:0
|
作者
Perez, B. [1 ]
Lopez, M. E. [1 ]
Palacios, D. [1 ]
机构
[1] Pontificia Univ Catolica Peru, Dept Ciencias, Secc Fis, Ave Univ 1801, Lima 32, Peru
关键词
Overlapping; LR-115; Monte Carlo methods; Diffusion chamber; Radon exposure levels; V function; NUCLEAR TRACK DETECTORS; SOIL-GAS; RADON MEASUREMENTS; DWELLINGS; SCHOOLS; AREA; RISK;
D O I
10.1016/j.radphyschem.2021.109470
中图分类号
O64 [物理化学(理论化学)、化学物理学];
学科分类号
070304 ; 081704 ;
摘要
A simulation program based on Monte Carlo methods was developed to study the behaviour of the overlapping effect in the LR-115 nuclear track detectors located inside a diffusion chamber. The relation between the nonoverlapped tracks and the radon exposure level that the detector was exposed was adopted. This study focuses on very high radon concentration levels found in soil gas, uranium mines, or underground places. These anomalous levels can influence the radiological risk related to inhalation of indoor radon or the spontaneous increases in thermal neutron background. LR-115 detector exposed to anomalous levels can register a large number of latent tracks on its surface. After an etching treatment, some visible tracks can be placed covering one or more visible tracks altering the LR-115 response. In order to develop this work and be more realistic, visible tracks were simulated taking into account radon exposure level, geometry and dimensions of the diffusion chamber, dimensions of the detector, the V function, the etching process and the reading process. Results show that the overlapping effect in the LR-115 inside a cylindrical diffusion chamber exposed to very high levels can be solved with an uncertainty of 5%. The same methodology can also be applied when considering other detectors and geometry and dimensions of a diffusion chamber.
引用
收藏
页数:6
相关论文
共 50 条
  • [21] Using the image processing in digital system to determine the nuclear parameters of LR-115 detector
    Firas Mohammed Ali Al-jomaily
    Radiation Detection Technology and Methods, 2021, 5 : 255 - 263
  • [22] Alpha track counting in LR-115 nuclear detector with optical Fourier digital system
    Eghan, MJ
    Bassuah, PKB
    OPTICS FOR THE QUALITY OF LIFE, PTS 1 AND 2, 2003, 4829 : 52 - 53
  • [23] THE EFFICIENCY AND ANGULAR SENSITIVITY OF THE LR-115 NUCLEAR TRACK DETECTOR TO ALPHA-PARTICLES
    PLANINIC, J
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION B-BEAM INTERACTIONS WITH MATERIALS AND ATOMS, 1992, 71 (01): : 95 - 98
  • [24] Etched-hole formation in LR-115 cellulose nitrate detector irradiated with fast neutrons
    Sawamura, Teruko
    Yamazaki, Hatsuo
    Nuclear Tracks and Radiation Measurements, 1988, 14 (04): : 461 - 466
  • [25] Theoretical and experimental study of the LR-115 detector response in a non-commercial radon monitor
    Perez, B.
    Lopez, M. E.
    Palacios, D.
    APPLIED RADIATION AND ISOTOPES, 2020, 160
  • [26] CALIBRATION OF LR-115 NUCLEAR TRACK DETECTOR FOR THE MEASUREMENT OF INDOOR LEVELS OF THORON AND ITS PROGENY
    RAMACHANDRAN, TV
    MURALEEDHARAN, TS
    RAMU, MCS
    INDIAN JOURNAL OF PURE & APPLIED PHYSICS, 1989, 27 (11) : 782 - 784
  • [27] Sensitivity of LR115 detector in diffusion chamber to 222Rn in the presence of 220Rn
    Koo, VSY
    Yip, CWY
    Ho, JPY
    Nikezic, D
    Yu, KN
    APPLIED RADIATION AND ISOTOPES, 2002, 56 (06) : 953 - 956
  • [28] Neutron dose evaluation inside high-energy accelerator irradiation vault using LR-115
    Ahn, Yunjin
    Kim, Sangrok
    Lee, Suhyoung
    APPLIED RADIATION AND ISOTOPES, 2024, 211
  • [29] A semi-empirical approach to estimate the parameters determining the LR-115 detector response in radon measurements
    Rojas, Jhonny
    Palacios, Daniel
    Pereyra, Patrizia
    Perez, Bertin
    Sajo Bohus, Laszlo
    Elena Lopez, Maria
    RADIATION MEASUREMENTS, 2018, 118 : 36 - 42
  • [30] ETCHED-HOLE FORMATION IN LR-115 CELLULOSE NITRATE DETECTOR IRRADIATED WITH FAST-NEUTRONS
    SAWAMURA, T
    YAMAZAKI, H
    NUCLEAR TRACKS AND RADIATION MEASUREMENTS, 1988, 14 (04): : 461 - 466