Cone beam computed tomography based image guidance and quality assessment of prostate cancer for magnetic resonance imaging-only radiotherapy in the pelvis

被引:4
|
作者
Edmund, Jens M. [1 ,2 ]
Andreasen, Daniel [3 ]
Van Leemput, Koen [3 ,4 ]
机构
[1] Univ Copenhagen, Gentofte & Herlev Hosp, Dept Oncol, Radiotherapy Res Unit, DK-2730 Herlev, Denmark
[2] Univ Copenhagen, Niels Bohr Inst, DK-2100 Copenhagen, Denmark
[3] Tech Univ Denmark, Dept Hlth Technol, DK-2800 Lyngby, Denmark
[4] Harvard Med Sch, Massachusetts Gen Hosp, Dept Radiol, Martinos Ctr Biomed Imaging, Boston, MA 02114 USA
关键词
MRI-only RT; IGRT; Synthetic CT; Pseudo CT; Magnetic resonance imaging; Radiotherapy; Cone beam CT; SYNTHETIC CT GENERATION; RADIATION-THERAPY; NEURAL-NETWORK; MRI SEQUENCES; PSEUDO-CT;
D O I
10.1016/j.phro.2021.05.001
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
Background and purpose: Radiotherapy (RT) based on magentic resonance imaging (MRI) only is currently used clinically in the pelvis. A synthetic computed tomography (sCT) is needed for dose planning. Here, we investigate the accuracy of cone beam CT (CBCT) based MRI-only image guided RT (IGRT) and sCT image quality. Materials and methods: CT, MRI and CBCT scans of ten prostate cancer patients were included. The MRI was converted to a sCT using a multi-atlas approach. The sCT, CT and MR images were auto-matched with the CBCT on the bony anatomy. Paired sCT-CT and sCT-CBCT data were created. CT numbers were converted to relative electron (RED) and mass densities (DES) using a standard calibration curve for the CT and sCT. For the CBCT RED/DES conversion, a phantom and paired CT-CBCT population based calibration curve was used. For the latter, the CBCT numbers were averaged in 100 HU bins and the known RED/DES of the CT were assigned. The paired sCT-CT and sCT-CBCT data were averaged in bins of 10 HU or 0.01 RED/DES. The median absolute error (MeAE) between the sCT-CT and sCT-CBCT bins was calculated. Wilcoxon rank-sum tests were carried out for the IGRT and MeAE study. Results: The mean sCT or MR IGRT difference from CT was <= 2 mm but significant differences were observed. A CBCT HU or phantom-based RED/DES MeAE did not estimate the sCT quality similar to a CT based MeAE but the CBCT population-based RED/DES MeAE did. Conclusions: MRI-only CBCT-based IGRT seems feasible but caution is advised. A MeAE around 0.1 DES could call for sCT quality inspection.
引用
收藏
页码:55 / 60
页数:6
相关论文
共 50 条
  • [31] Magnetic Resonance Imaging only Workflow for Radiotherapy Simulation and Planning in Prostate Cancer
    Kerkmeijer, L. G. W.
    Maspero, M.
    Meijer, G. J.
    van Zyp, J. R. N. van der Voort
    de Boer, C. J.
    van den Berg, C. A. T.
    CLINICAL ONCOLOGY, 2018, 30 (11) : 692 - 701
  • [32] Dose and Image Quality of Cone-Beam Computed Tomography as Compared With Conventional Multislice Computed Tomography in Abdominal Imaging
    Schegerer, Alexander A.
    Lechel, Ursula
    Ritter, Manuel
    Weisser, Gerald
    Fink, Christian
    Brix, Gunnar
    INVESTIGATIVE RADIOLOGY, 2014, 49 (10) : 675 - 684
  • [33] Clinical experience and cost evaluation of magnetic resonance imaging-only workflow in radiation therapy planning of prostate cancer
    Keyrilainen, Jani
    Sjoblom, Olli
    Turnbull-Smith, Sonja
    Hovirinta, Taru
    Minn, Heikki
    PHYSICS & IMAGING IN RADIATION ONCOLOGY, 2021, 19 : 66 - 71
  • [34] Personalized Assessment of kV Cone Beam Computed Tomography Doses in Image-guided Radiotherapy of Pediatric Cancer Patients
    Zhang, Yibao
    Yan, Yulong
    Nath, Ravinder
    Bao, Shanglian
    Deng, Jun
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2012, 83 (05): : 1649 - 1654
  • [35] LIPIODOL: A POTENTIAL DIRECT SURROGATE FOR CONE-BEAM COMPUTED TOMOGRAPHY IMAGE GUIDANCE IN RADIOTHERAPY OF LIVER TUMOR
    Yue, Jinbo
    Sun, Xindong
    Cai, Jing
    Yin, Fang-Fang
    Yin, Yong
    Zhu, Jian
    Lu, Jie
    Liu, Tonghai
    Yu, Jinming
    Shi, Xuetao
    Song, Jinlong
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2012, 82 (02): : 834 - 841
  • [36] Patient-specific synthetic magnetic resonance imaging generation from cone beam computed tomography for image guidance in liver stereotactic body radiation therapy
    Zhang, Zeyu
    Jiang, Zhuoran
    Zhong, Hualiang
    Lu, Ke
    Yin, Fang-Fang
    Ren, Lei
    PRECISION RADIATION ONCOLOGY, 2022, 6 (02): : 110 - 118
  • [37] Intrafractional motion in stereotactic body radiotherapy of spinal metastases utilizing cone beam computed tomography image guidance
    Svestad, Jorund Graadal
    Ramberg, Christina
    Skar, Birgitte
    Hellebust, Taran Paulsen
    PHYSICS & IMAGING IN RADIATION ONCOLOGY, 2019, 12 : 1 - 6
  • [38] Optimal frequency of image guidance with cone-beam computed tomography in conventionally fractionated radiotherapy for lung tumors
    Olivier, K.
    Li, J.
    Shi, W.
    Newlin, H.
    Chvetsov, A.
    Liu, C.
    Palta, J.
    Yeung, A. R.
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2008, 72 (01): : S439 - S440
  • [39] Cone beam CT versus electronic portal imaging for daily image-guidance in prostate radiotherapy
    White, E
    Moseley, D
    Catton, C
    Wiltshire, K
    Sharpe, M
    Gospodarowicz, M
    Warde, P
    Jaffray, D
    RADIOTHERAPY AND ONCOLOGY, 2005, 76 : S4 - S4
  • [40] Urethra contouring on computed tomography urethrogram versus magnetic resonance imaging for stereotactic body radiotherapy in prostate cancer
    Ong, Wee Loon
    Hupman, M. Allan
    Davidson, Melanie
    Ruschin, Mark
    Detsky, Jay
    Liu, Stanley
    Vesprini, Danny
    Loblaw, Andrew
    CLINICAL AND TRANSLATIONAL RADIATION ONCOLOGY, 2024, 45