Cone beam computed tomography based image guidance and quality assessment of prostate cancer for magnetic resonance imaging-only radiotherapy in the pelvis

被引:4
|
作者
Edmund, Jens M. [1 ,2 ]
Andreasen, Daniel [3 ]
Van Leemput, Koen [3 ,4 ]
机构
[1] Univ Copenhagen, Gentofte & Herlev Hosp, Dept Oncol, Radiotherapy Res Unit, DK-2730 Herlev, Denmark
[2] Univ Copenhagen, Niels Bohr Inst, DK-2100 Copenhagen, Denmark
[3] Tech Univ Denmark, Dept Hlth Technol, DK-2800 Lyngby, Denmark
[4] Harvard Med Sch, Massachusetts Gen Hosp, Dept Radiol, Martinos Ctr Biomed Imaging, Boston, MA 02114 USA
关键词
MRI-only RT; IGRT; Synthetic CT; Pseudo CT; Magnetic resonance imaging; Radiotherapy; Cone beam CT; SYNTHETIC CT GENERATION; RADIATION-THERAPY; NEURAL-NETWORK; MRI SEQUENCES; PSEUDO-CT;
D O I
10.1016/j.phro.2021.05.001
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
Background and purpose: Radiotherapy (RT) based on magentic resonance imaging (MRI) only is currently used clinically in the pelvis. A synthetic computed tomography (sCT) is needed for dose planning. Here, we investigate the accuracy of cone beam CT (CBCT) based MRI-only image guided RT (IGRT) and sCT image quality. Materials and methods: CT, MRI and CBCT scans of ten prostate cancer patients were included. The MRI was converted to a sCT using a multi-atlas approach. The sCT, CT and MR images were auto-matched with the CBCT on the bony anatomy. Paired sCT-CT and sCT-CBCT data were created. CT numbers were converted to relative electron (RED) and mass densities (DES) using a standard calibration curve for the CT and sCT. For the CBCT RED/DES conversion, a phantom and paired CT-CBCT population based calibration curve was used. For the latter, the CBCT numbers were averaged in 100 HU bins and the known RED/DES of the CT were assigned. The paired sCT-CT and sCT-CBCT data were averaged in bins of 10 HU or 0.01 RED/DES. The median absolute error (MeAE) between the sCT-CT and sCT-CBCT bins was calculated. Wilcoxon rank-sum tests were carried out for the IGRT and MeAE study. Results: The mean sCT or MR IGRT difference from CT was <= 2 mm but significant differences were observed. A CBCT HU or phantom-based RED/DES MeAE did not estimate the sCT quality similar to a CT based MeAE but the CBCT population-based RED/DES MeAE did. Conclusions: MRI-only CBCT-based IGRT seems feasible but caution is advised. A MeAE around 0.1 DES could call for sCT quality inspection.
引用
收藏
页码:55 / 60
页数:6
相关论文
共 50 条
  • [21] Evaluation of the Geometric and Dosimetric Accuracy of Synthetic Computed Tomography Images for Magnetic Resonance Imaging-only Stereotactic Radiosurgery
    Fatemi, Ali
    Kanakamedala, Madhava R.
    Yang, Claus Chunli
    Morris, Bart
    Duggar, William N.
    Vijayakumar, Srinivasan
    CUREUS JOURNAL OF MEDICAL SCIENCE, 2019, 11 (04)
  • [22] Fractionated changes in prostate cancer radiotherapy using cone-beam computed tomography
    Huang, Tzung-Chi
    Chou, Kuei-Ting
    Yang, Shih-Neng
    Chang, Chih-Kai
    Liang, Ji-An
    Zhang, Geoffrey
    MEDICAL DOSIMETRY, 2015, 40 (03) : 222 - 225
  • [23] A comprehensive evaluation of angular range and separation on image quality, image registration, and imaging dose for cone beam computed tomography in radiotherapy
    Men, Kuo
    Dai, Jianrong
    MEDICAL DOSIMETRY, 2019, 44 (01) : 67 - 73
  • [24] Assessment of cone beam computed tomography image quality and dose for commonly used pre-sets in external beam radiotherapy
    Al-Kabkabi, Abdullah
    Ramachandran, Prabhakar
    Aamry, Ali
    Tamam, Nissren
    Abuhadi, Nouf H.
    Johary, Yehia
    Aamri, Hussin
    Sulieman, Abdelmoneim
    Trapp, Jamie
    RADIATION PHYSICS AND CHEMISTRY, 2022, 199
  • [25] "Dose of the day" based on cone beam computed tomography and deformable image registration for lung cancer radiotherapy
    Yuan, Zilong
    Rong, Yi
    Benedict, Stanley H.
    Daly, Megan E.
    Qiu, Jianfeng
    Yamamoto, Tokihiro
    JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, 2020, 21 (01): : 88 - 94
  • [26] QUALITY ASSESSMENT OF FRAMELESS FRACTIONATED STEREOTACTIC RADIOTHERAPY USING CONE BEAM COMPUTED TOMOGRAPHY
    Peng, Lee-Cheng
    Kahler, Darren
    Samant, Sanjiv
    Li, Jonathan
    Amdur, Robert
    Palta, Jatinder R.
    Liu, Chihray
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2010, 78 (05): : 1586 - 1593
  • [27] Cost Effectiveness of Magnetic Resonance Imaging Guidance Versus Computed Tomography Guidance for Stereotactic Body Radiotherapy
    Giuliani, Jacopo
    Mandara, Marta
    Fiorica, Francesco
    EUROPEAN UROLOGY ONCOLOGY, 2024, 7 (03): : 634 - 635
  • [28] Applications of Computed Tomography, Magnetic Resonance Imaging and Magnetic Resonance Spectroscopy for Planning External Beam Radiotherapy
    Payne, Geoffrey S.
    Charles-Edwards, Elizabeth
    South, Christopher P.
    CURRENT MEDICAL IMAGING REVIEWS, 2008, 4 (04) : 236 - 249
  • [29] Image-guided radiotherapy for liver cancer using respiratorycorrelated computed tomography and cone-beam computed tomography
    Guckenberger, Matthias
    Sweeney, Reinhart A.
    Wilbert, Juergen
    Krieger, Thomas
    Richter, Anne
    Baier, Kurt
    Mueller, Gerd
    Sauer, Otto
    Flentje, Michael
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2008, 71 (01): : 297 - 304
  • [30] Set-up errors in prostate cancer radiotherapy based on cone-beam computed tomography.
    Trignani, M.
    Caponigro, G.
    Di Biase, M.
    Bagala, P.
    Falco, M. D.
    Vinciguerra, A.
    Augurio, A.
    Di Tommaso, M.
    Caravatta, L.
    Genovesi, D.
    RADIOTHERAPY AND ONCOLOGY, 2017, 123 : S723 - S723