Cone beam computed tomography based image guidance and quality assessment of prostate cancer for magnetic resonance imaging-only radiotherapy in the pelvis

被引:4
|
作者
Edmund, Jens M. [1 ,2 ]
Andreasen, Daniel [3 ]
Van Leemput, Koen [3 ,4 ]
机构
[1] Univ Copenhagen, Gentofte & Herlev Hosp, Dept Oncol, Radiotherapy Res Unit, DK-2730 Herlev, Denmark
[2] Univ Copenhagen, Niels Bohr Inst, DK-2100 Copenhagen, Denmark
[3] Tech Univ Denmark, Dept Hlth Technol, DK-2800 Lyngby, Denmark
[4] Harvard Med Sch, Massachusetts Gen Hosp, Dept Radiol, Martinos Ctr Biomed Imaging, Boston, MA 02114 USA
关键词
MRI-only RT; IGRT; Synthetic CT; Pseudo CT; Magnetic resonance imaging; Radiotherapy; Cone beam CT; SYNTHETIC CT GENERATION; RADIATION-THERAPY; NEURAL-NETWORK; MRI SEQUENCES; PSEUDO-CT;
D O I
10.1016/j.phro.2021.05.001
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
Background and purpose: Radiotherapy (RT) based on magentic resonance imaging (MRI) only is currently used clinically in the pelvis. A synthetic computed tomography (sCT) is needed for dose planning. Here, we investigate the accuracy of cone beam CT (CBCT) based MRI-only image guided RT (IGRT) and sCT image quality. Materials and methods: CT, MRI and CBCT scans of ten prostate cancer patients were included. The MRI was converted to a sCT using a multi-atlas approach. The sCT, CT and MR images were auto-matched with the CBCT on the bony anatomy. Paired sCT-CT and sCT-CBCT data were created. CT numbers were converted to relative electron (RED) and mass densities (DES) using a standard calibration curve for the CT and sCT. For the CBCT RED/DES conversion, a phantom and paired CT-CBCT population based calibration curve was used. For the latter, the CBCT numbers were averaged in 100 HU bins and the known RED/DES of the CT were assigned. The paired sCT-CT and sCT-CBCT data were averaged in bins of 10 HU or 0.01 RED/DES. The median absolute error (MeAE) between the sCT-CT and sCT-CBCT bins was calculated. Wilcoxon rank-sum tests were carried out for the IGRT and MeAE study. Results: The mean sCT or MR IGRT difference from CT was <= 2 mm but significant differences were observed. A CBCT HU or phantom-based RED/DES MeAE did not estimate the sCT quality similar to a CT based MeAE but the CBCT population-based RED/DES MeAE did. Conclusions: MRI-only CBCT-based IGRT seems feasible but caution is advised. A MeAE around 0.1 DES could call for sCT quality inspection.
引用
收藏
页码:55 / 60
页数:6
相关论文
共 50 条
  • [1] Cone beam computed tomography image guidance within a magnetic resonance imaging-only planning workflow
    O'Connor, Laura M.
    Quinn, Alesha
    Denley, Samuel
    Leigh, Lucy
    Martin, Jarad
    Dowling, Jason A.
    Skehan, Kate
    Warren-Forward, Helen
    Greer, Peter B.
    PHYSICS & IMAGING IN RADIATION ONCOLOGY, 2023, 27
  • [2] Synthetic computed tomography based dose calculation in prostate cancer patients with hip prostheses for magnetic resonance imaging-only radiotherapy
    Koivula, Lauri
    Seppala, Tiina
    Collan, Juhani
    Visapaa, Harri
    Tenhunen, Mikko
    Korhonen, Arthur
    PHYSICS & IMAGING IN RADIATION ONCOLOGY, 2023, 27
  • [3] Stereotactic Body Radiotherapy for Prostate Cancer with Magnetic Resonance Imaging or Computed Tomography Guidance
    Chang, E.
    Choi, S.
    Fnu, R. Z.
    Tang, C.
    Hassanzadeh, C. J.
    Mohamad, O.
    Frank, S. J.
    Shah, S. J.
    Mok, H.
    Kudchadker, R.
    Du, W.
    Wang, J.
    Yang, J.
    Mayo, L. L.
    Chronowski, G. M.
    Hoffman, K. E.
    McGuire, S. E.
    Kuban, D. A.
    Nguyen, Q. N.
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2024, 120 (02): : E518 - E519
  • [4] Evaluation of a commercial synthetic computed tomography generation solution for magnetic resonance imaging-only radiotherapy
    Gonzalez-Moya, A.
    Dufreneix, S.
    Ouyessad, N.
    Guillerminet, C.
    Autret, D.
    JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, 2021, 22 (06): : 191 - 197
  • [5] Cone beam computed tomography for dose calculation quality assurance for magnetic resonance-only radiotherapy
    Wyatt, Jonathan J.
    Pearson, Rachel A.
    Walker, Christopher P.
    Brooks, Rachel L.
    Pilling, Karen
    McCallum, Hazel M.
    PHYSICS & IMAGING IN RADIATION ONCOLOGY, 2021, 17 : 71 - 76
  • [6] Feasibility of magnetic resonance imaging-only rectum radiotherapy with a commercial synthetic computed tomography generation solution
    Maspero, Matteo
    Tyyger, Marcus D.
    Tijssen, Rob H. N.
    Seevinck, Peter R.
    Intven, Martijn P. W.
    van den Berg, Cornelis A. T.
    PHYSICS & IMAGING IN RADIATION ONCOLOGY, 2018, 7 : 58 - 64
  • [7] Cone beam computed tomography guided treatment delivery and planning verification for magnetic resonance imaging only radiotherapy of the brain
    Edmund, Jens M.
    Andreasen, Daniel
    Mahmood, Faisal
    Van Leemput, Koen
    ACTA ONCOLOGICA, 2015, 54 (09) : 1496 - 1500
  • [8] Assessment of image quality in maxillofacial cone-beam computed tomography imaging
    Gamache, Casey
    English, Jeryl D.
    Salas-Lopez, Anna M.
    Rong, John
    Akyalcin, Sercan
    SEMINARS IN ORTHODONTICS, 2015, 21 (04) : 248 - 253
  • [9] Bone quality assessment based on cone beam computed tomography imaging
    Hua, Yan
    Nackaerts, Olivia
    Duyck, Joke
    Maes, Frederik
    Jacobs, Reinhilde
    CLINICAL ORAL IMPLANTS RESEARCH, 2009, 20 (08) : 767 - 771
  • [10] Assessment of dosimetric and positioning accuracy of a magnetic resonance imaging-only solution for external beam radiotherapy of pelvic anatomy
    Kemppainen, Reko
    Suilamo, Sami
    Ranta, Iiro
    Pesola, Marko
    Halkola, Aleksi
    Eufemio, Alvin
    Minn, Heikki
    Keyrilainen, Jani
    PHYSICS & IMAGING IN RADIATION ONCOLOGY, 2019, 11 : 1 - 8