Cervical artery dissection: Improved diagnosis by B-Flow ultrasound

被引:0
|
作者
Clevert, D. -A.
Jung, E. M.
Johnson, T.
Kubale, R.
Rupp, N.
Schoenberg, S. O.
Reiser, M.
机构
[1] Univ Munich, Dept Clin Radiol, D-81377 Munich, Germany
[2] Inst Diagnost Radiol, Passau, Germany
[3] Inst Radiol, Pirmasens, Germany
关键词
B-Flow imaging; carotid artery; vertebral artery;
D O I
暂无
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Objective: The objective of this study was to evaluate the efficiency of B-Flow ultrasound in diagnosing supraaortic vessel dissections compared with other ultrasound techniques including B scan, Color-Coded Doppler (CCDS) and Power Doppler (PD). Materials and methods: Eighty-eight patients with suspected arterial dissection of the neck vessels were included in this prospective trial. All patients were examined using B scan, Color-Coded Doppler sonography and Power Doppler. After documentation of the diagnoses, the patients were additionally examined by B-Flow ultrasound. Contrast-enhanced magnetic resonance angiography (MRA) was used as reference standard in all cases. Results: Dissections of the carotid artery (n=19) and of the vertebral artery (n=35) were found in 44 patients. B-Flow imaging identified 52 of 54 arterial dissections that were confirmed by MRA. There were no false-positive diagnoses in ultrasound examination. The sensitivity of ultrasound examination using B scan, CCDS and PD in detecting all dissections was 95.9% and 99.1% with additional B-Flow examination. Sensitivity using B-Flow increased from 98.3% to 100% for carotid dissections and from 93.3% to 94.3% for vertebral artery dissections. Due to the lack of overwriting artifacts, B-Flow imaging detected residual flow within the false lumen more precisely. The reduced effect of the ultrasound probe angle facilitated imaging of fissures, membranes and low flow phenomena and improved the identification of low-reflection wall structures. The cine mode of the B-Flow showed undulating membrane movement most clearly. Contrast-enhanced MRA in conjunction with axial T1 and T2 weighted sequences enabled the best visualization of intramural hematomas. Conclusion: B-Flow imaging can significantly increase the sensitivity of ultrasound examination for dissections of the neck vessels. It also improves the visualization of flow within the true and false lumen, of hypoechoic thrombi and of intramural hematoma.
引用
收藏
页码:141 / 153
页数:13
相关论文
共 50 条
  • [31] Sensitivity of neurovascular ultrasound for the detection of spontaneous cervical artery dissection
    Nebelsieck, J.
    Sengelhoff, C.
    Nassenstein, I.
    Maintz, D.
    Kuhlenbaeumer, G.
    Nabavi, D. G.
    Ringelstein, E. B.
    Dittrich, R.
    JOURNAL OF CLINICAL NEUROSCIENCE, 2009, 16 (01) : 79 - 82
  • [32] Hepatic Artery Delineation on Ultrasound Volumes Comparing B-Flow and Color Doppler for Postoperative Monitoring of Pediatric Liver Transplants
    Dammann, Elena
    Steinmeister, Leonhard
    Groth, Michael
    Herden, Uta
    Fischer, Lutz
    Brinkert, Florian
    Beime, Jan
    Tozakidou, Magdalini
    Bannas, Peter
    Herrmann, Jochen
    DIAGNOSTICS, 2024, 14 (06)
  • [33] B-flow and B-flow spatio-temporal image correlation in visualizing fetal cardiac blood flow
    Pooh, RK
    Korai, A
    CROATIAN MEDICAL JOURNAL, 2005, 46 (05) : 808 - 811
  • [34] Plaque imaging of the internal carotid artery - Correlation of B-flow imaging with histopathology
    Reiter, M.
    Horvat, R.
    Puchner, S.
    Rinner, W.
    Polterauer, P.
    Lammer, J.
    Minar, E.
    Bucek, R. A.
    AMERICAN JOURNAL OF NEURORADIOLOGY, 2007, 28 (01) : 122 - 126
  • [35] Diagnostics and characterisation of preocclusive stenoses and occlusions of the internal carotid artery with B-flow
    E. M. Jung
    R. Kubale
    G. Ritter
    M. T. Gallegos
    K. -P. Jungius
    N. Rupp
    D. -A. Clevert
    European Radiology, 2007, 17 : 439 - 447
  • [36] Cervical Carotid Artery Dissection: Current Review of Diagnosis and Treatment
    Patel, Raj Ramabhai
    Adam, Richard
    Maldjian, Catherine
    Lincoln, Christie M.
    Yuen, Annie
    Arneja, Amrita
    CARDIOLOGY IN REVIEW, 2012, 20 (03) : 145 - 152
  • [37] Results of a UK questionnaire of diagnosis and treatment in cervical artery dissection
    Menon, R. K.
    Markus, H. S.
    Norris, J. W.
    JOURNAL OF NEUROLOGY NEUROSURGERY AND PSYCHIATRY, 2008, 79 (05): : 612 - 612
  • [38] Diagnostics and characterisation of preocclusive stenoses and occlusions of the internal carotid artery with B-flow
    Jung, E. M.
    Kubale, R.
    Ritter, G.
    Gallegos, M. T.
    Jungius, K. -P.
    Rupp, N.
    Clevert, D. -A.
    EUROPEAN RADIOLOGY, 2007, 17 (02) : 439 - 447
  • [39] Cervical artery dissection
    Abou-Chebl A.
    Current Treatment Options in Cardiovascular Medicine, 2009, 11 (2) : 167 - 175
  • [40] Cervical artery dissection
    Neau, JP
    Petit, E
    Gil, R
    PRESSE MEDICALE, 2001, 30 (38): : 1882 - 1889