Cervical artery dissection: Improved diagnosis by B-Flow ultrasound

被引:0
|
作者
Clevert, D. -A.
Jung, E. M.
Johnson, T.
Kubale, R.
Rupp, N.
Schoenberg, S. O.
Reiser, M.
机构
[1] Univ Munich, Dept Clin Radiol, D-81377 Munich, Germany
[2] Inst Diagnost Radiol, Passau, Germany
[3] Inst Radiol, Pirmasens, Germany
关键词
B-Flow imaging; carotid artery; vertebral artery;
D O I
暂无
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Objective: The objective of this study was to evaluate the efficiency of B-Flow ultrasound in diagnosing supraaortic vessel dissections compared with other ultrasound techniques including B scan, Color-Coded Doppler (CCDS) and Power Doppler (PD). Materials and methods: Eighty-eight patients with suspected arterial dissection of the neck vessels were included in this prospective trial. All patients were examined using B scan, Color-Coded Doppler sonography and Power Doppler. After documentation of the diagnoses, the patients were additionally examined by B-Flow ultrasound. Contrast-enhanced magnetic resonance angiography (MRA) was used as reference standard in all cases. Results: Dissections of the carotid artery (n=19) and of the vertebral artery (n=35) were found in 44 patients. B-Flow imaging identified 52 of 54 arterial dissections that were confirmed by MRA. There were no false-positive diagnoses in ultrasound examination. The sensitivity of ultrasound examination using B scan, CCDS and PD in detecting all dissections was 95.9% and 99.1% with additional B-Flow examination. Sensitivity using B-Flow increased from 98.3% to 100% for carotid dissections and from 93.3% to 94.3% for vertebral artery dissections. Due to the lack of overwriting artifacts, B-Flow imaging detected residual flow within the false lumen more precisely. The reduced effect of the ultrasound probe angle facilitated imaging of fissures, membranes and low flow phenomena and improved the identification of low-reflection wall structures. The cine mode of the B-Flow showed undulating membrane movement most clearly. Contrast-enhanced MRA in conjunction with axial T1 and T2 weighted sequences enabled the best visualization of intramural hematomas. Conclusion: B-Flow imaging can significantly increase the sensitivity of ultrasound examination for dissections of the neck vessels. It also improves the visualization of flow within the true and false lumen, of hypoechoic thrombi and of intramural hematoma.
引用
收藏
页码:141 / 153
页数:13
相关论文
共 50 条
  • [41] Proximal bifurcation of hepatic artery: Novel findings on hepatic arteries demonstrated by ultrasound Doppler imaging, B-flow, and US angiography
    Hitoshi Tochio
    Nobuhiro Iwasaki
    Hitomi Nakamura
    Keiko Nakayama
    Toshiko Soga
    Shinichi Nishiuma
    Toyokazu Fukunaga
    Yoshihiro Okabe
    Hiroshi Kashida
    Masahiro Hirasa
    Yasuyoshi Ibuki
    Toshiaki Fujimoto
    Yoshito Morimoto
    Masatoshi Kudo
    Syusuke Tomita
    Yutaka Konishi
    Akio Orino
    Journal of Medical Ultrasonics, 2002, 29 (1) : 11 - 17
  • [42] B-flow imaging for the measurement of residual lumen diameter of renal artery stenosis
    Tola, Muharrem
    Yurdakul, Mehmet
    Ozbulbul, Nilgun Isiksalan
    JOURNAL OF CLINICAL ULTRASOUND, 2012, 40 (02) : 85 - 90
  • [43] Advanced ultrasound applications in the assessment of renal transplants: contrast-enhanced ultrasound, elastography, and B-flow
    Tara A. Morgan
    Priyanka Jha
    Liina Poder
    Stefanie Weinstein
    Abdominal Radiology, 2018, 43 : 2604 - 2614
  • [44] Is frequent ultrasound monitoring of spontaneous cervical artery dissection clinically useful?
    Rundek, Tatjana
    Katsnelson, Michael
    NEUROLOGY, 2010, 75 (21) : 1858 - 1859
  • [45] Clinical Usefulness of Serial Duplex Ultrasound in Cervical Artery Dissection Patients
    Traenka, Christopher
    Streifler, Jonathan
    Lyrer, Philippe
    Engelter, Stefan T.
    CEREBROVASCULAR DISEASES, 2020, 49 (02) : 206 - 215
  • [46] Advanced ultrasound applications in the assessment of renal transplants: contrast-enhanced ultrasound, elastography, and B-flow
    Morgan, Tara A.
    Jha, Priyanka
    Poder, Liina
    Weinstein, Stefanie
    ABDOMINAL RADIOLOGY, 2018, 43 (10) : 2604 - 2614
  • [47] Fast B-flow imaging: A method for improving frame rate in Golay coded B-flow Imaging
    Leavens, Claudia
    Burns, Peter N.
    Sherar, Michael D.
    IEEE TRANSACTIONS ON ULTRASONICS FERROELECTRICS AND FREQUENCY CONTROL, 2007, 54 (11) : 2272 - 2282
  • [48] B-mode blood flow (B-flow) imaging
    Chiao, RY
    Mo, LY
    Hall, AL
    Miller, SC
    Thomenius, KE
    2000 IEEE ULTRASONICS SYMPOSIUM PROCEEDINGS, VOLS 1 AND 2, 2000, : 1469 - 1472
  • [49] A new marker for diagnosis of thyroid papillary cancer - B-flow twinkling sign
    Brunese, Luca
    Romeo, Antonio
    Iorio, Sergio
    Napolitano, Giuseppina
    Fucili, Stefano
    Biondi, Bernadette
    Vallone, Gianfranco
    Sodano, Antonio
    JOURNAL OF ULTRASOUND IN MEDICINE, 2008, 27 (08) : 1187 - 1194
  • [50] Thrombin injection under B-flow and ultrasound guidance: A safe and effective treatment of pseudoaneurysms
    Li, Lu
    Deng, Hongyan
    Yuan, Ya
    Ye, Xinhua
    VASCULAR, 2024, 32 (01) : 147 - 153