Hepatic Artery Delineation on Ultrasound Volumes Comparing B-Flow and Color Doppler for Postoperative Monitoring of Pediatric Liver Transplants

被引:0
|
作者
Dammann, Elena [1 ]
Steinmeister, Leonhard [2 ]
Groth, Michael [3 ]
Herden, Uta [4 ]
Fischer, Lutz [4 ]
Brinkert, Florian [5 ]
Beime, Jan [5 ]
Tozakidou, Magdalini [1 ]
Bannas, Peter [6 ]
Herrmann, Jochen [1 ]
机构
[1] Univ Med Ctr Hamburg Eppendorf, Dept Diagnost & Intervent Radiol & Nucl Med, Sect Pediat Radiol, D-20251 Hamburg, Germany
[2] Alta Klin Bielefeld, Dept Radiol, D-33602 Bielefeld, Germany
[3] Radiol Vechta, Marienstr 6-8, D-49377 Vechta, Germany
[4] Univ Med Ctr Hamburg Eppendorf, Dept Visceral Transplantat, D-20251 Hamburg, Germany
[5] Univ Med Ctr Hamburg Eppendorf, Dept Pediat, D-20251 Hamburg, Germany
[6] Univ Med Ctr Hamburg Eppendorf, Dept Diagnost & Intervent Radiol & Nucl Med, D-20251 Hamburg, Germany
关键词
B-flow sonography; Color Doppler sonography; hepatic artery; pediatric liver transplantation; vascular complications; VASCULAR COMPLICATIONS; POWER DOPPLER; SONOGRAPHY; EXPERIENCE;
D O I
10.3390/diagnostics14060617
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
(1) Background: Accurate hepatic artery (HA) depiction following pediatric liver transplantation (LT) is essential for graft surveillance but challenging on ultrasound (US). This study assesses if improved HA delineation can be achieved by recording two-dimensional US volumes in Color Doppler (CD) and B-flow technique. (2) Methods: Of 42 consecutive LT, 37 cases were included, and HA delineation was retrospectively rated using a four-point score (0 = HA not detectable, 3 = HA fully detectable, separable from portal vein) within 48 h post-LT (U1) and before discharge (U2). (3) Results: Adding B-flow compared with CD alone showed superior results at neohilar (U1: 2.2 +/- 1.0 vs. 1.1 +/- 0.8, p < 0.0001; U2: 2.5 +/- 0.8 vs. 1.5 +/- 0.9, p < 0.0001) and segmental levels (U1: 2.8 +/- 0.6 vs. 0.6 +/- 0.8, p < 0.0001; U2: 2.8 +/- 0.6 vs. 0.7 +/- 0.5, p < 0.0001). (4) Conclusions: Standardized US volume recordings combining B-flow and CD can effectively delineate the HA along its vascular course in pediatric LT. The technique should be further evaluated as a standard monitoring instrument to rule out vascular complications after LT.
引用
收藏
页数:10
相关论文
共 16 条
  • [1] B-flow imaging of the hepatic vasculature: Correlation with color Doppler sonography
    Wachsberg, Ronald H.
    AMERICAN JOURNAL OF ROENTGENOLOGY, 2007, 188 (06) : W522 - W533
  • [2] Superb Microvascular Imaging (SMI) Compared with Color Doppler Ultrasound for the Assessment of Hepatic Artery in Pediatric Liver Transplants: A Feasibility Study
    Collaku, Elona
    Simonini, Roberto
    Balbi, Maurizio
    Bonaffini, Pietro Andrea
    Valle, Clarissa
    Morzenti, Cesare
    Faseli, Romina Fatima
    Ferrari, Alberto
    Ippolito, Davide
    Marra, Paolo
    Barbui, Tiziano
    Sironi, Sandro
    DIAGNOSTICS, 2022, 12 (06)
  • [3] Proximal bifurcation of hepatic artery: Novel findings on hepatic arteries demonstrated by ultrasound Doppler imaging, B-flow, and US angiography
    Hitoshi Tochio
    Nobuhiro Iwasaki
    Hitomi Nakamura
    Keiko Nakayama
    Toshiko Soga
    Shinichi Nishiuma
    Toyokazu Fukunaga
    Yoshihiro Okabe
    Hiroshi Kashida
    Masahiro Hirasa
    Yasuyoshi Ibuki
    Toshiaki Fujimoto
    Yoshito Morimoto
    Masatoshi Kudo
    Syusuke Tomita
    Yutaka Konishi
    Akio Orino
    Journal of Medical Ultrasonics, 2002, 29 (1) : 11 - 17
  • [4] Prediction of early hepatic artery thrombosis by intraoperative color Doppler ultrasound in pediatric segmental liver transplantation
    Gu, Li H.
    Fang, Hua
    Li, Feng H.
    Li, Ping
    Zhu, Cai X.
    Zhu, Jian J.
    Zhang, Shi J.
    CLINICAL TRANSPLANTATION, 2012, 26 (04) : 571 - 576
  • [5] Improved diagnosis of vascular dissection by ultrasound B-flow: a comparison with color-coded Doppler and power Doppler sonography
    Clevert, DA
    Rupp, N
    Reiser, M
    Jung, EM
    EUROPEAN RADIOLOGY, 2005, 15 (02) : 342 - 347
  • [6] Doppler ultrasonography blood flow changes of the hepatic artery in liver transplants complicated with cholangitis
    Ozturk, Ulu F.
    Soy, Ayvazoglu E. H.
    Uslu, N.
    Haberal, M.
    TRANSPLANTATION, 2021, 105 (08) : 167 - 167
  • [7] Doppler ultrasonography blood flow changes of the hepatic artery in liver transplants complicated with cholangitis
    Ozturk, Funda Ulu
    Tezcan, Sehnaz
    Soy, Ebru Hatice Ayvazoglu
    Uslu, Nihal
    Haberal, Mehmet
    JOURNAL OF CLINICAL ULTRASOUND, 2023, 51 (05) : 860 - 865
  • [8] COLOR-FLOW DOPPLER ULTRASOUND DIAGNOSIS OF A PSEUDOANEURYSM OF THE HEPATIC-ARTERY FOLLOWING LIVER-TRANSPLANTATION
    WORTHY, SA
    OLLIFF, JFC
    OLLIFF, SP
    BUCKELS, JAC
    JOURNAL OF CLINICAL ULTRASOUND, 1994, 22 (07) : 461 - 465
  • [9] Improved diagnosis of vascular dissection by ultrasound B-flow: a comparison with color-coded Doppler and power Doppler sonography
    D.-A. Clevert
    N. Rupp
    M. Reiser
    E. M. Jung
    European Radiology, 2005, 15 : 342 - 347
  • [10] B-Flow Sonography vs. Color Doppler Sonography for the Assessment of Vascularity in Pediatric Kidney Transplantation
    Dammann, Elena
    Groth, Michael
    Schild, Raphael-Sebastian
    Lemke, Anja
    Oh, Jun
    Adam, Gerhard
    Herrmann, Jochen
    ROFO-FORTSCHRITTE AUF DEM GEBIET DER RONTGENSTRAHLEN UND DER BILDGEBENDEN VERFAHREN, 2021, 193 (01): : 49 - 60