Biometry with a new swept-source optical coherence tomography biometer: Repeatability and agreement with an optical low-coherence reflectometry device

被引:73
|
作者
Kurian, Mathew [1 ]
Negalur, Nikhil [1 ]
Das, Sudeep [1 ]
Puttaiah, Narendra K. [1 ]
Haria, Dhawal [1 ]
Tejal, S. J. [1 ]
Thakkar, Maithil M. [1 ]
机构
[1] Narayana Nethralaya, Bangalore, Karnataka, India
来源
关键词
INTRAOCULAR-LENS POWER; INTERFEROMETRY; ACCURACY;
D O I
10.1016/j.jcrs.2016.01.038
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
PURPOSE: To assess the repeatability of a new swept-source optical coherence tomography (SS-OCT) biometer (IOLMaster 700) and evaluate the agreement with an optical low-coherence reflectometry (OLCR) biometer (Lenstar 900) in cataractous eyes. SETTING: Tertiary eyecare facility. DESIGN: Prospective evaluation of a diagnostic test. METHODS: Eyes of patients had 3 consecutive scans acquired by the same operator. The repeatability of measurements was assessed using the within-subject standard deviation and coefficient of variation (CoV). Agreement between the mean measurements of each machine was evaluated. RESULTS: The study comprised 100 eyes of 100 patients. The median lens thickness and axial length (AL) measurements were significantly greater (P < .001) with SS-OCT (4.29 mm and 23.5 mm, respectively, versus 4.25 mm and 23.4 mm, respectively); anterior chamber depth (ACD) was greater with OLCR (2.72 mm versus 2.70 mm, respectively) (P < .001). The within-subject standard deviation and CoV of the AL (0.01 and 0.05, respectively) and the ACD (0.04 and 1.22, respectively) measurements showed lower variability with SS-OCT (0.05 and 0.21, respectively, for AL; 0.06 and 1.99, respectively, for ACD) than with OLCR. Good agreement was seen for anterior segment measurements between the 2 devices. The 95% limits of agreement of most parameters fell within the test retest variability of the parameters. The SS-OCT biometer also showed better penetration in dense posterior subcapsular cataracts, measuring AL successfully in 96% of cases. CONCLUSIONS: The new SS-OCT biometer showed good repeatability and agreement with the OLCR biometer. The SS-OCT biometer measured the AL with fewer dropouts compared with the OLCR even in dense cataracts. (C) 2016 ASCRS and ESCRS
引用
收藏
页码:577 / 581
页数:5
相关论文
共 50 条
  • [31] Comparison of ocular biometric measurements between a new swept-source optical coherence tomography and a common optical low coherence reflectometry
    Rongrong Gao
    Hao Chen
    Giacomo Savini
    Yaxin Miao
    Xiaorui Wang
    Jing Yang
    Weiqi Zhao
    Qinmei Wang
    Jinhai Huang
    Scientific Reports, 7
  • [32] Comparison of ocular biometric measurements between a new swept-source optical coherence tomography and a common optical low coherence reflectometry
    Gao, Rongrong
    Chen, Hao
    Savini, Giacomo
    Miao, Yaxin
    Wang, Xiaorui
    Yang, Jing
    Zhao, Weiqi
    Wang, Qinmei
    Huang, Jinhai
    SCIENTIFIC REPORTS, 2017, 7
  • [33] The Effect of Cycloplegia on the Biometer for Optical Low-coherence Reflectometry
    Yakar, Konuralp
    KLINISCHE MONATSBLATTER FUR AUGENHEILKUNDE, 2023,
  • [34] Comparison of a new swept-source optical biometer with a partial coherence interferometry
    Hyo Kyung Lee
    Mee Kum Kim
    BMC Ophthalmology, 18
  • [35] Clinical comparison of a new swept-source optical coherence tomography-based optical biometer and a time-domain optical coherence tomography-based optical biometer
    Srivannaboon, Sabong
    Chirapapaisan, Chareenun
    Chonpimai, Pratuangsri
    Loket, Siriwan
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2015, 41 (10): : 2224 - 2232
  • [36] Advances in swept-source optical coherence tomography and optical coherence tomography angiography
    Zheng, Fang
    Deng, Xiaofeng
    Zhang, Qi
    He, Jingliang
    Ye, Panpan
    Liu, Shan
    Li, Peng
    Zhou, Jian
    Fang, Xiaoyun
    ADVANCES IN OPHTHALMOLOGY PRACTICE AND RESEARCH, 2023, 3 (02): : 67 - 79
  • [37] Agreement between a new optical low coherence reflectometry biometer and an anterior segment optical coherence tomographer
    Yiran Wang
    Ting Wan
    Luze Liu
    Yuyuan Xue
    Xinyao Chen
    Giacomo Savini
    Domenico Schiano-Lomoriello
    Xingtao Zhou
    Jinjin Yu
    Jinhai Huang
    Eye and Vision, 10
  • [38] Agreement between a new optical low coherence reflectometry biometer and an anterior segment optical coherence tomographer
    Wang, Yiran
    Wan, Ting
    Liu, Luze
    Xue, Yuyuan
    Chen, Xinyao
    Savini, Giacomo
    Schiano-Lomoriello, Domenico
    Zhou, Xingtao
    Yu, Jinjin
    Huang, Jinhai
    EYE AND VISION, 2023, 10 (01)
  • [39] Detecting macular disease with a biometry device using swept-source optical coherence tomography Reply
    Hirnschall, Nino
    Leisser, Christoph
    Radda, Stephan
    Findl, Oliver
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2016, 42 (10): : 1545 - 1545
  • [40] Comparison of Clinical Outcomes between Swept-source Optical Coherence Tomography Biometer and Partial Coherence Interferometer
    Jang, Mirinae
    Lee, Hye Jin
    Lee, Sang-Yoon
    Kim, Jin Young
    Ma, Dae Joong
    Jeong, Jin Ho
    JOURNAL OF THE KOREAN OPHTHALMOLOGICAL SOCIETY, 2020, 61 (08): : 905 - 910