Biometry with a new swept-source optical coherence tomography biometer: Repeatability and agreement with an optical low-coherence reflectometry device

被引:73
|
作者
Kurian, Mathew [1 ]
Negalur, Nikhil [1 ]
Das, Sudeep [1 ]
Puttaiah, Narendra K. [1 ]
Haria, Dhawal [1 ]
Tejal, S. J. [1 ]
Thakkar, Maithil M. [1 ]
机构
[1] Narayana Nethralaya, Bangalore, Karnataka, India
来源
关键词
INTRAOCULAR-LENS POWER; INTERFEROMETRY; ACCURACY;
D O I
10.1016/j.jcrs.2016.01.038
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
PURPOSE: To assess the repeatability of a new swept-source optical coherence tomography (SS-OCT) biometer (IOLMaster 700) and evaluate the agreement with an optical low-coherence reflectometry (OLCR) biometer (Lenstar 900) in cataractous eyes. SETTING: Tertiary eyecare facility. DESIGN: Prospective evaluation of a diagnostic test. METHODS: Eyes of patients had 3 consecutive scans acquired by the same operator. The repeatability of measurements was assessed using the within-subject standard deviation and coefficient of variation (CoV). Agreement between the mean measurements of each machine was evaluated. RESULTS: The study comprised 100 eyes of 100 patients. The median lens thickness and axial length (AL) measurements were significantly greater (P < .001) with SS-OCT (4.29 mm and 23.5 mm, respectively, versus 4.25 mm and 23.4 mm, respectively); anterior chamber depth (ACD) was greater with OLCR (2.72 mm versus 2.70 mm, respectively) (P < .001). The within-subject standard deviation and CoV of the AL (0.01 and 0.05, respectively) and the ACD (0.04 and 1.22, respectively) measurements showed lower variability with SS-OCT (0.05 and 0.21, respectively, for AL; 0.06 and 1.99, respectively, for ACD) than with OLCR. Good agreement was seen for anterior segment measurements between the 2 devices. The 95% limits of agreement of most parameters fell within the test retest variability of the parameters. The SS-OCT biometer also showed better penetration in dense posterior subcapsular cataracts, measuring AL successfully in 96% of cases. CONCLUSIONS: The new SS-OCT biometer showed good repeatability and agreement with the OLCR biometer. The SS-OCT biometer measured the AL with fewer dropouts compared with the OLCR even in dense cataracts. (C) 2016 ASCRS and ESCRS
引用
收藏
页码:577 / 581
页数:5
相关论文
共 50 条
  • [21] Effect of orthokeratology on precision and agreement assessment of a new swept-source optical coherence tomography biometer
    Shu, Bao
    Bao, Fangjun
    Savini, Giacomo
    Lu, Weicong
    Tu, Ruixue
    Chen, Haisi
    Song, Benhao
    Wang, Qinmei
    Huang, Jinhai
    EYE AND VISION, 2020, 7 (01)
  • [22] Repeatability of 2 swept-source OCT biometers and 1 optical low-coherence reflectometry biometer (vol 47, pg 1302, 2021)
    Fisus, Andreea D.
    Hirnschall, Nino D.
    Ruiss, Manuel
    Pilwachs, Caroline
    Georgiev, Stefan
    Findl, Oliver
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2022, 48 (06): : 750 - 750
  • [23] Repeatability and agreement of swept-source optical coherence tomography and partial coherence interferometry biometers in myopes
    Ardoy, Elisa Garcia
    Mateos, Nuria
    Roda, Laura
    Sierra, Oscar Torrado
    Baptista, Antonio M.
    Serra, Pedro M.
    CLINICAL AND EXPERIMENTAL OPTOMETRY, 2023, 106 (07) : 783 - 792
  • [24] Comparison of Optical Low-Coherence Reflectometry and Swept-Source OCT-Based Biometry Devices in Dense Cataracts
    Vasavada, Shail A.
    Patel, Priyanka
    Vaishnav, Vineet R.
    Ashena, Zahra
    Srivastava, Samaresh
    Vasavada, Vaishali
    Nanavaty, Mayank A.
    JOURNAL OF REFRACTIVE SURGERY, 2020, 36 (08) : 557 - 564
  • [25] Comparison of a new optical biometry with an optical low-coherence reflectometry for ocular biometry
    Guler, Emre
    Kulak, Ali Ender
    Totan, Yuksel
    Yuvarlak, Armagan
    Hepsen, Ibrahim Feyzi
    CONTACT LENS & ANTERIOR EYE, 2016, 39 (05): : 336 - 341
  • [26] Comparison of a new biometer using swept-source optical coherence tomography and a conventional biometer using partial coherence interferometry
    Higashiyama, Tomoaki
    Mori, Hazuki
    Nakajima, Fumi
    Ohji, Masahito
    PLOS ONE, 2018, 13 (04):
  • [27] Detecting macular disease with a biometry device using swept-source optical coherence tomography
    Tan, Colin S.
    Cheong, Kai Xiong
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2016, 42 (10): : 1544 - 1545
  • [28] Measurement agreement between a new biometer based on partial coherence interferometry and a validated biometer based on optical low-coherence reflectometry
    Li, Junhua
    Chen, Hao
    Savini, Giacomo
    Lu, Weicong
    Yu, Xinxin
    Bao, Fangjun
    Wang, Qinmei
    Huang, Jinhai
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2016, 42 (01): : 68 - 75
  • [29] Repeatability of a new swept-source optical coherence tomographer and agreement with other three optical biometers
    Cheng, Shi-Ming
    Zhang, Jia-Sheng
    Shao, Xu
    Wu, Ze-Tong
    Li, Tian-Tian
    Wang, Po
    Lin, Jun-Hai
    Yu, A-Yong
    GRAEFES ARCHIVE FOR CLINICAL AND EXPERIMENTAL OPHTHALMOLOGY, 2022, 260 (07) : 2271 - 2281
  • [30] Repeatability of a new swept-source optical coherence tomographer and agreement with other three optical biometers
    Shi-Ming Cheng
    Jia-Sheng Zhang
    Xu Shao
    Ze-Tong Wu
    Tian-Tian Li
    Po Wang
    Jun-Hai Lin
    A-Yong Yu
    Graefe's Archive for Clinical and Experimental Ophthalmology, 2022, 260 : 2271 - 2281