Differential pulse voltammetric simultaneous determination of noradrenalin and acetaminophen using a hematoxylin biosensor

被引:58
|
作者
Nasirizadeh, Navid [1 ]
Zare, Hamid R. [1 ]
机构
[1] Yazd Univ, Dept Chem, Yazd 89195741, Iran
关键词
Noradrenalin; Acetaminophen; Differential pulse voltammetry; Biosensor; Hematoxylin; GLASSY-CARBON ELECTRODE; ADENINE-DINUCLEOTIDE NADH; ASCORBIC-ACID; URIC-ACID; ELECTROCATALYTIC OXIDATION; PASTE ELECTRODE; DERIVATIVE SPECTROPHOTOMETRY; PHARMACEUTICAL FORMULATIONS; ELECTROCHEMICAL PROPERTIES; MASS-SPECTROMETRY;
D O I
10.1016/j.talanta.2009.07.044
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A highly efficient noradrenalin (NA) biosensor was fabricated on the basis of hematoxylin electrodeposited on a glassy carbon electrode, GCE. The cyclic voltammetric responses of the hematoxylin biosensor at various scan rates, which were obtained in a 0.25 mmol L-1 NA solution, showed the characteristic shape typical of an ECcat process. The kinetic parameters such as electron transfer coefficient, alpha, the catalytic electron transfer rate constant, k', and the standard catalytic electron transfer rate constant, k(0), for oxidation of NA at the hematoxylin biosensor surface were estimated using cyclic and RDE voltammetry. The peaks of differential pulse voltammetric (DPV) for NA and acetaminophen (AC) oxidation at the hematoxylin biosensor surface were clearly separated from each other when they co-exited in the physiological pH (pH 7.0). It was, therefore, possible to simultaneously determine NA and AC in the samples at a hematoxylin biosensor. Linear calibration curves were obtained for 5.0 x 10(-1) to 65.40 mu mol L-1 and 65.40-274.20 mu mol L-1 of NA, and for 12.00-59.10 mu mol L-1 and 59.10-261.70 mu mol L-1 of AC. The sensitivities of the biosensor to NA in the absence and presence of AC were found virtually the same, which indicates the fact that the electrocatalytic oxidation processes of NA are independent of AC and, therefore, simultaneous or independent measurements of the two analytes (NA and AC) are possible without any interference. The results of 16 successive measurements show an average voltammetric peak current of 1.13 +/- 0.03 mu A for an electrolyte solution containing 5.00 mu mol L-1 NA. The hematoxylin biosensor has been satisfactorily used for the determination of NA and AC in pharmaceutical formulations. The results obtained, using the biosensor, are in very good agreement with those declared in the label of pharmaceutical inhalation products. (C) 2009 Elsevier B.V. All rights reserved.
引用
收藏
页码:656 / 663
页数:8
相关论文
共 50 条
  • [41] Differential pulse voltammetric determination of tin in the presence of noble metals
    Monticelli, D
    Psaro, R
    Pozzi, A
    Dossi, C
    Recchia, S
    ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2005, 383 (01) : 115 - 121
  • [42] Differential pulse voltammetric determination of eugenol at a pencil graphite electrode
    Saglam, Ozlem
    Dilgin, Didem Giray
    Ertek, Bensu
    Dilgin, Yusuf
    MATERIALS SCIENCE & ENGINEERING C-MATERIALS FOR BIOLOGICAL APPLICATIONS, 2016, 60 : 156 - 162
  • [43] Differential pulse voltammetric determination of tin in the presence of noble metals
    Damiano Monticelli
    Rinaldo Psaro
    Andrea Pozzi
    Carlo Dossi
    Sandro Recchia
    Analytical and Bioanalytical Chemistry, 2005, 383 : 115 - 121
  • [44] Differential pulse voltammetric determination of uranium in low concentration streams
    Sawant, LR
    Kalsi, PK
    Kulkarni, AV
    Vaidyanathan, S
    JOURNAL OF RADIOANALYTICAL AND NUCLEAR CHEMISTRY-ARTICLES, 1996, 207 (01): : 39 - 43
  • [45] Differential pulse voltammetric determination of uranium in low concentration streams
    Sawant, L.R.
    Kalsi, P.K.
    Kulkarni, A.V.
    Vaidyanathan, S.
    Journal of Radioanalytical and Nuclear Chemistry, 1996, 207 (01): : 39 - 43
  • [46] Differential Pulse Voltammetric Determination of Trace Indium in Rocks and Soils
    沈观略
    岩石矿物学杂志, 1985, (04) : 365 - 367
  • [47] Use of the differential pulse cathodic adsorptive stripping voltammetric method for the simultaneous determination of trace amounts of cadmium and zinc
    Shemirani, F.
    Rajabi, M.
    JOURNAL OF ANALYTICAL CHEMISTRY, 2007, 62 (09) : 878 - 883
  • [48] A glassy carbon electrode modified with carboxylated diamond nanoparticles for differential pulse voltammetric simultaneous determination of guanine and adenine
    Habibi, Biuck
    Jahanbakhshi, Mojtaba
    MICROCHIMICA ACTA, 2016, 183 (07) : 2317 - 2325
  • [49] A glassy carbon electrode modified with carboxylated diamond nanoparticles for differential pulse voltammetric simultaneous determination of guanine and adenine
    Biuck Habibi
    Mojtaba Jahanbakhshi
    Microchimica Acta, 2016, 183 : 2317 - 2325
  • [50] Simultaneous Differential Pulse Voltammetric Determination of Nitrophenol-type Compound by Artificial Intelligent and Machine Learning Methods
    Gao, Ling
    Ren, Shouxin
    COMPUTER COMMUNICATION AND MANAGEMENT, 2011, 5 : 411 - 415